Performance of WQ Series Submersible Sewage Pump

Flow Range:8-1000m3/h

Head Range:5-50m

Power Range:1.1-250kw

Temperature:-20ºC-60ºC

Material:Cast Iron,Stainless Steel

Work Pressure:≤1.6MPa
 

Product Overview of WQ Series Submersible Sewage Pump
QW type non-clog submersible sewage pump is made up of motor and pump, which are separated through oil isolation room and mechanical seal, it is short in length that motor and pump share the same axle (rotor), the structure is compact. 

Structure Features of WQ Series Submersible Sewage Pump
1. Signal line: for motor power above 11kw, we suggest pump equipped with control box, which would protect the pump fully from leakage, phase reversal, short circuit, overheated, overload, etc.. 
2. Motor stator: its insulation is B grade or F grade. 
3. Water leakage probe. This component is installed in the oil room, if the mechanical seal was damaged, and water enters into the oil room, it will send out the signal to the control system so as to stop the pump. 
4. Mechanical seal: Adopting in-series seal, the material is the wear-resisting carbonization tungsten, featuring being reliable, wear-resisting, longer life, etc. 
5. Impeller: have better handling capacity, can reduce the trouble of jamming and twisting of big fiber rubbish, etc. 
6. Pump body: harmonize with impeller, ensure the pump has high efficiency. 
7. Seal rings: Installed at the mouth place of pump body, can change the sealed ring after long time operating, so as to ensure the pump runs with the best efficiency. 

Advantages of WQ Series Submersible Sewage Pump
1. Adopt big flow non-clog design, improving the ability to pass dirty things greatly. 
2. The design is rational, with high efficiency, and the energy-saving is remarkable. 
3. Adopts in series mechanical seal, the material is the wear-resisting carbonization tungsten, featuring being durable, wear-resisting, can running for more than 8000 hours continuously safely. 
4. The structure of the pump is compact, small, may move conveniently, installation is simple and convenient, it is submerged into the water, no need to build the pump house, reduce construction cost greatly. 
5. There is probe in the oil room of the pump, if the pump side mechanical seal is damaged and water enter into the oil room, it would give off signals so as to protect the pump. 
6. Can be equipped with control box according to the needs of user, it will protect the pump from electric leakage, water leakage, overload and overheated, etc. guarantee the pump operates reliably and safely. 
7. The automatic coupling installation system of one pair of guides, it is convenient for the installation and maintenance of the pump, no need to enter into the sewage hole. 
8. The float switch, according to the necessary water level changing. Control the start and stop of the pump automatically, no people needed to guard it. 
9. According to use situation, the motor can adopt water jacket the-third party circulation cooling system type, which can guarantee the safe operation of the pump under the anhydrous (dry type) state. 
10. Installation can be fixed automatic coupling installation or non-fixed portable installation, which can satisfy different occasions. 

Working Conditions of WQ Series Submersible Sewage Pump
1. Temperature 0f medium not exceeding 60ºC,gravity 1.0~1.3kg/dm3,and PH value between 5~9. 
2. For pump without internal gravity flow circulation cooling system,its motor above liquid surface by less than 1/3. 
3. Generally, pumps shall be working within the range of head to protect the motor from overloading.To work at the full head.please specify when placing an order for our convenience in manufacturing. 
4. The current Of motor during the process of operation shall not exceed the rated current of motor. 

Applications of WQ Series Submersible Sewage Pump
This series of pumps are mainly used in municipal engineering,buildings,industrial sewage discharge,sewage treatment in environmental protection,factories and mines to deliver sewage,wastewater and rainwater etc,containing solid substances and long fibre.Stainless steel may also be used to deliver corrosive medium. 

Q: What does the temperature range of the pump mean?
Not be too cold or hot water, will be frozen.
Q: How to determine the pump installation elevation, why should we determine the pump installation elevation?
Determination of pump installation elevation: the geometric height between the suction well level and the center line of the pump impeller, plus the hydraulic loss of the suction pipe, is the actual installation height of the pump. (notice: if the suction level is higher than the center of the impeller, it should be negative)To determine the water pump installation elevation reasons: general water pump nameplate on the "NPSH" value, the above calculation of the value must be less than this NPSH value, so as to ensure that water pump is not prone to cavitation.[NPSH] - allowable cavitation margin is to determine the conditions of use of the pump cavitation margin.
Q: What are the categories of pumps?
As long as you see, you need flow, lift, power
Q: Pump adapter joint net outside tube, what is the principle?
At once the room after the fire, the internal fire pool once water shortage, the water tank can be within the fire truck hit the water chamber through the pump adapter connected to the fire extinguishing effect.
Q: I live in a house that uses a pump to push water from a tank to the bathroom and kitchen. It has a sensor that detects if water is flowing and pushes it much harder. Recently, it has been pushing the water for a second or less then it completely stops for a while. It's like a pulse of water then nothing. Can anyone give me feedback on what is wrong here? Thank you.
from okorder :Self-priming pump working principle is: the pump before you start in the pump shell filled with water (or) from the water in the pump housing.Start after high-speed rotating impeller flow to the vortex in the impeller, shell, then the entry form the vacuum, the inlet non-return door open, within the air into the pump suction tube and the impeller, to arrive at the outer edge.Self-priming pump is a self-priming centrifugal pump, it has compact structure, convenient operation, stable operation, easy maintenance, high efficiency, long service life, and have strong self-priming capacity, etc.Line does not need to install the bottom valve, only to ensure storage in pump body before work are quantitative liquid.Pump after the normal starting, impeller liquid of suction chamber and inlet line of air suction, and can completely mixed within the impeller, the function of centrifugal force, and liquid with gas to the vortex flow volume outside edge, the impeller has a certain thickness is formed on the outer edge of the white foam belt and high-speed rotating liquid ring.Gas-liquid mixture into the gas-liquid separation chamber through diffusion tube.At this time, due to the flow rate suddenly drops, lighter gas is separated from the mixture of liquid and gas through the pump body spit continues to rise.After degassing of liquid to liquid storage chamber, and the reflux hole again into the impeller, and impeller with inhalation of gases from the inlet line again mix, flow under the action of the high-speed rotating impeller and the impeller outer edge....As the process cycle, decreasing the air in the suction line, until all gas absorption, complete the self-priming process, pump put into normal operation. What you said phenomenon should be pipeline leak, which leads to the self-priming pump process is repeated.
Q: Intelligent pump controller, water is full water transfer automatically shows the next pool of water shortage, what is the matter?
The intelligent controller of water pump is full of water and automatically shows the shortage of water in the lower pool. The reason is that the sensor is out of order or the line is out of contact. First of all, make sure that the upper limit of your controller is normally open or normally closed. When the upper limit is reached, does this point change? If the original upper limit position is normally open, check the switch and pump insulation.A pump is used to increase the pressure of a liquid or gas, the flow conveying machinery, and "jump" or "flow" is a homonym, is a transliteration of the English pump, is a device used to move liquids, gases or special fluid medium, which is reactive to the fluid machinery. The heart of man and animal can be said to be a natural pump, which carries blood to all parts of the body.
Q: 1.5 kW three-phase pump with 600 meters line, should match what big line?
Resistivity of copper conductors is 0.017 ohm mm / m, R= P L/S, the resistance can be obtained by 600 meters 2.5 mm - single stranded conductor is 4.08 ohms, and rated current 1.5KW three-phase pump is about 3A, so the pressure drop resistance of the wire leading to the U=4.08X3=12.24V. So if the supply voltage can be stabilized at 380V~400V, with 2.5 mm - cable; if the supply voltage is between 370~390V, with 4 mm - cable. (above is copper core, aluminum core shall be increased by 1)
Q: I have a quot;Rainbow Lifeguard Quiet One 6000external pump that I would like to use on a new chiller for my tank. The pump is rated at a little over 1500 gallons per hour. I'm debating between a couple of chillers, one that has a max flow rate of 1300 gph and another that has a max of 960.I know that you are only supposed to put any valves on the outflow side of the pump and lessening the flow to 1300 from 1500 doesn't seem like it would be that big of a problem, but I was curious it cutting it back to 960 would be hard on the pump in the long run. (I'm leaning towards the bigger chiller as although it may be overkill for my tank, it would let me have a little more water circulation.)
I wouldn't restrict it more than about 10% or so personally. I would ask you to think about this: The rated flow rate on a pump is under perfect operating conditions and is usually a mathmatical model that cannot really be acheived in the real world. Your pump probbaly is several gallons per hours behind that. If the tank is on a stand and the pump on the floor, the head pressure alone may slow it to 1300 or below. Additional tubing, especially hard angles will further reduce the flow. I would suggest you get a flow meter ( you can probably borrow one from a plumber for a day) and test the actual flow rate in your set up. Remember that the chiller will further reduce the flow itself. Odds are good you are closer to the needed 1300 than you think. You can also install a small diverter valve in the line. Basically splitting the output from the pump into two lines. One can carry about 1250 GPH and the other the rest which it just returns to the tank unchilled. Hope that helps MM
Q: When the pump is connected in parallel, will the head and flow change?
Depends on how you do it.If you have a pump, the original network is the same, you add a pump, the result is the head and flow increases, the efficiency also changed, increase the number of head and flow, depending on the network characteristics, network characteristics such as steep increase, economy is also poor, which is not recommended. In fact, the actual flow of two pumps plus the actual lift equal, the problem is that the head, flow point of operation has changed.If it is new design, according to the required flow calculation of the required head, according to the head, half of the flow to select the pump, that is, two pumps flow volume, lift equal.
Q: Mechanic really could not locate the origin of the leak but says the water pump needs to be replaced and says it's a lot of work and would cost $350. How can the origin of the leak be determined. He used a pump and raised the pressure on the radiator but that didn't reveal anything either. Please help.
It's probably the water pump, but if he has to take the timing belt off anyway, ask him if he can just put a new timing belt on for only the cost of the timing belt.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords