• Single Stage Double Suction Pump System 1
Single Stage Double Suction Pump

Single Stage Double Suction Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT or L/C
Min Order Qty:
1 Set unit
Supply Capability:
1000 Sets Per Year unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
They are mainly used for municipal water supply, central heating, air-conditioning, fire fighting system, water treatment, drainage pump station, power plant, shipping industry, petro-chemical industry and so on.
Q:Weap seal is starting to leak and getting some noise from the water pump. These cars are not as easy as a 1969 Camaro to change the water pump. Can you please give me some guidance? Thx in advance.
2001 Chrysler 300
Q:Could it make coolant quot;Boilquot;? Ive heard myc ar's behavior is Normal, and most likely just heavy condenstaion as it DOES go away, also the behavior of the coolant and the tank.. but i DO know the Water Pump is quot;Weeping,or quot;Seeping,so i wonder what interaction that would have ont he Cooling side of the motor; what effects can it produce? What would i notice?My 1991 Calais 2.5L quot;Iron Duke,
Steam coming from your headlight on a rainy night is NORMAL, since the halogen bulb makes a lot of heat. This turns the water into water vapor, (steam) as it attempts to dry out. If you don't physically hear the bearings in your water pump, or watch colored fluid drip out from under your engine, then your water pump is JUST FINE!!! STOP WORRYING! I answered one of your questions the other day. If you take my advice, your engine will run at it's best. For extra protection, drain and flush your cooling system out, and use Mercedes coolant. Dex-cool has been proved to be a potentially bad coolant. READ the dexcool litigation websites. Mercedes coolant, which is YELLOW in color, will last for 150,000 miles, and is a time tested WINNER!!! Use ONLY top tier fuels (read about this on web) and use ONLY synthetic oil, like Mobil One. CLEAN your idle air control valve and throttle plate. AND STOP WORRYING!
Q:I'm building a 79 SBC (old style) 350 and have a new stock water pump...what hose and where does it go from the top of the water pump to wherever? Heater hose? Or can I just leave it plugged. No A/C I just need a heater/defroster, etc...
New thermostat, yet have you ever tried a decrease temp thermostat? Our RV 479 CI used to run a million/2 way up and three/4 in end/bypass and close to the pink line up mountain roads. I placed a decrease thermostat and it runs a million/4 and <a million/2 end/bypass. severe temps are dry out electric powered cord rubber insulators and that i have had to replace diverse the ignition wires. also it is frustrating to crank reason you have become vapor lock. The gas contained in the gas is so warm is turns to vapor and the gas pump can no longer longer suck gas because it isn't reliable adequate to suck vapor, in ordinary words liquid gas. if so, flooded start up tactics might want to artwork. floor the gas, shop it floored and crank the starter. Pump like loopy also, yet shop you foot in truth floored. it would want to start up.
Q:i took off the lower unit to fix the gears. im not sure ill be able to put it back on with out knowing how things work in there.so how exactly does the water get pumped. and what does it have to do with the gears, because even though the prop wasn't turning, the water was still pumping.thanks.
What make?model etc. that is the first step,then contact maker for details
Q:55KW motor driven lift 70M, the displacement of 180 cubic meters per hour of water pump, the configuration should be no problem, but after the start of the current to 170A (rated 100A), off a small valve to the current export half to reach the rated current. Why current will close a small valve instead of small? Will close a small valve will not affect traffic flow can be? To the 180 party?
If the power line is too long or too small, power line is too long or too small will cause excessive current. Valve shut down certainly affect the flow. When the valve is in the semi open state, the water pump out of the water flow down, the power to reduce, so the current drops.
Q:Why does the pump decay when connected in parallel?
Pump parallel mainly solves the problem of insufficient flow. After parallel, the flow is two and the sum of the pumps. When the flow rate increases, the pressure loss of the pipeline will increase, so the water pump flow in parallel will not be the sum of the two pump flow, but less than the sum of the flow rate. The solution is to increase the diameter of the water supply pipe, reduce the angle bend and shorten the distance.........
Q:What's the difference between a double suction pump and a single suction pump?
From the literal sense to understand, double suction pump is the impeller at both ends of the water inlet, and the single suction pump is from the impeller at one end of the water.Dual suction is mainly used in the process of large flow and low lift. When the pump flow is greater than or equal to 280m3/h, the caliber of 200mm or more, if the use of a single suction pump, then the speed requirements of about 1450rpm in order to achieve the suction requirements. However, if the double suction pump is used, the size and weight of the pump are reduced, and the speed can be increased, the volumetric efficiency is increased, and the reliability of the equipment is improved.Single suction pump, also known as end suction pump, single suction pump flow is relatively small. The same flow, single suction of small size, but the axial force, bearing a large burden. The cost of single suction pump is low, the price is reasonable, widely used, but in many ways it is not as good as double suction pump. If the inlet pressure is higher, the general choice of double suction wheel can be solved. Because the axial force balance of the impeller of the single suction pump is a big problem.
Q:i mean, the water that runs through the ground from rain and ends up in the pit in the basement,is it clean to drink in an emergency? live close to a public road where they salt for snow and ice, so do you suppose that is in the water?
The only thing it would be suitable for is flushing toilets.
Q:no water is running my deep well pump kicks on every 15 min. it runs for 1-2 min when it kicks off then a noise like someone threw a ball against the house. can you help
it sounds like either your pressure switch is messed up or your pressure tank isn't working right
Q:The plumber has disappeared on us with 99% of the job done. Our new basement remodel has baseboard heating installed, a water pump attached to the furnace/boiler, but no heat downstairs because their is no thermostat. I haven't checked to see if he did any wiring. (Wouldn't that be an electrician's job?) I've ordered a wireless thermostat kit, and I'm assuming installation instructions for the base are included, but it hasn't arrived yet. What should I do to get that pump pumping hot water to keep us nice and cozy?
That part in the picture is a high limit control with manual reset. It has nothing to do with the pump. You will need more than a thermostat to control the added pump. When you have more than one pump the system is zoned .You need a switching relay panel (Taco SR502) that not only turns on the pump , but also the burner. There is a lot to know here and it's best left to a heating contractor.

1. Manufacturer Overview

Location Weihai,China
Year Established 2011
Annual Output Value Below US$1 Million
Main Markets "North America
South America
Southeast Asia
Africa
Oceania
Mid East
Central America
Northern Europe
South Asia
"
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Qingdao port; Shanghai port
Export Percentage 71% - 80%
No.of Employees in Trade Department Above 100 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: Above 400,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered;Design Service Offered
Product Price Range High and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords