DIN 24255 End Suction Centrifugal Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
End Suction Centrifugal Pump
1.Structure of End Suction Centrifugal Pump Description
End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.
End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.
2.Main Features of the End Suction Water Pump
• very easy to be installed and maintained
•Back pull-out design
•Driven through flexible coupling
•Customized design is available, OEM and ODM are welcomed.
•Horizontally and vertically installation as different pipeline system
3.End Suction Water Pump Specification
4.Picture of End Suction Pump
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q: Which professional friends ask, I encountered a problem in the design of fire pump head 90 meters, flow rate is 20/S, power is 37KW, but the construction side to buy the pump head and flow are achieved, but the power is only 30KW, this relationship? If you can, let me know by the way, thank you
- No problem, despite the good use of different water pump factory manufacturing process is different, the product of the rich value of different factors, power difference is inevitable, as long as the flow and head to meet your use requirements.The calculation formula tells you: your flow is 72 tons / hour, lift 90 meters, motor power P=2.73HQ/0.75*1.2=28.5KW
- Q: What does 'MCL' Unit stands for water pump. How can convert this Meter head of the pump. For example : 50 MCL to ------- MTR HEAD. What is the formula?
- What Does Mlc Stand For
- Q: i wanna use a water pump to pump air...but im afraid that it might burn or sth....
- the pump designed for water will not work very well at all (any type of pump). its effieciecy will be very low. you will have low volume and low pressure. the pump will also be damaged, making it unsuitable to use as a water pump after its failed attempt at use as an air pump. Why dont you find an air blower? if your experimenting you can find one in every car heater system, so check out the car wreckers yard. Car heater air blowers are high volume low pressure. If you want a big unit get one out of a bus! If you want a high pressure low volume air pump you could use an old refrigerator compressor, or a standard air compressor. hope this helps..
- Q: In 2005, the water pump, export pressure in recent years decreased year by year, the running current is increasing, there are 4 pumps are like this. Professional personnel advice please!
- The reasons are as follows:(1) motor guide bearing wear, water pump rubber bearing wear, sealing ring wearMotor or water pump bearings wear, will make the submersible pump in the machine on the wrong state of work, serious damage to submersible pumps, stator windings burned. The method is to repair or replace damaged bearings and bushings.(2) thrust bearing wear, submerged pump impeller and lower cover wearThis situation will also make the submersible pump on the machine in an abnormal state of work, serious damage to the submersible pump. The treatment method is to check the cause of the wear of the thrust bearing. Whether the mechanical seal of the shaft extension is damaged or not, which causes sand particles and impurities to enter the inner cavity of the motor, causes excessive wear of the thrust bearing. If it is caused by the mechanical seal of the submersible pump, the replacement of the thrust bearing, thrust plate and impeller, lower cover plate and other parts shall be replaced by mechanical seals at the shaft extension end.(3) the flow of the submersible pump is too large or too smallThe use of submersible pumps flow beyond the scope of use will make the motor overload of centrifugal pump or mixed flow pump, excessive flow, the pump shaft power increases, the motor overload; for the axial flow pump, the flow is too small, the pump shaft power increases, the motor overload. The treatment method is to adjust the valve properly, reduce the flow rate of the centrifugal pump or the mixed flow pump (increase the axial flow pump), and make the flow of the pump in the normal range of use.(4) the shaft of the submersible pump is bent and the bearings are not concentricThis is a serious case of submersible pumps, should be immediately overhauled, straighten the bent shaft, replace the unqualified bearings, re assembled submersible pumps.
- Q: Which is the better option for a home water pump? a submersible pump or floor based pump?
- In case of pump failure, it's much easier to repair/replace a floor based pump plumbed with isolation valves and unions. I've replaced a few due to motor failures and flood damage. Arguably, the submersible pump wouldn't have suffered damage due to flooding. Another consideration is vertical pump height. A floor based pump has to draw a vacuum to induce water to flow up to the impeller. This limits the practical draw to between 25 and 30 ft. Much more than that height and the vacuum will exceed the vapor pressure of the the water, boiling it rather than pumping it. A special device can be used to boost the lift: an ejector is placed down the well. Water is pumped down to the ejector, which pulls additional water back up using the venturi effect. This method suffers from additional friction losses but has clear advantages. If you need to pump water up a well more than 20 feet vertical, you should consider a submersible pump, particularly if you are concerned about the possibility of the water table lowering.
- Q: my water is frozen from pump to faucets,do i thaw from pump to faucet ,or faucet to pump?
- Faucet to pump. It will relieve the pressure in the lines.
- Q: i just moved into a house that has a small (about 40 gal) pond. i wanted to put fish in it. i have everything but the water pump. i've been looking around and i've found many solar fountain heads (about $30) that are pretty cheap and then i found a solar oxygenator for $100. which one would help the fish more? flowing water or just oxygen?
- Flowing water adds oxygen into the water... So Id go with that one.
- Q: I think the water pump in my Oceanic BioCube is going up. What is a good brand that would be compatible? It is 29 gallons. Thanks.
- If okorder or just your local pet store and see if you can't buy a pump with a similar/same output.
- Q: 2004 chevy impala 3.4 v6 The small leak is right behind the pulley of the water pump. Car is not overheating .the leak is only for a little while then it stops . water pump seems to be working fine but the leak ,what could it be ?
- it's the seal - it needs to get fixed soon
- Q: my 98 expedition keeps over heating, i replaced the water pump, thermostat,coolant. it will be fine one minute then it overheats. weather im on the road or sitting at a light. i also replaced the fan clutch. thanks!
- Check the compression,could be a broken ring.
Send your message to us
DIN 24255 End Suction Centrifugal Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords