Perkins Genset Diesel Generator 48kw To 680kw With Digital Auto-Start Panel
- Loading Port:
- Guangzhou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Perkins Genset Diesel Generator 48kw To 680kw With Digital Auto-Start Panel
Quick Detail:
1.UK Perkins water cooled engine:1103A-33TG2,1104A-44TG1,1106C-E66TAG4
2. 24V DC start motor and storage battery
3. ac brushless 4 poles ,self-excited alternator
4.deepsea,smartgen Digital auto-start panel
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRP10 | 7 | 9 | 8 | 10 | 403D-11 | ≤252 | 3 | 1.131 | 77*81 |
GNRP15 | 10 | 13 | 12 | 15 | 403D-15 | ≤264 | 3 | 1.496 | 84*94 |
GNRP23 | 16 | 20 | 18 | 23 | 404D-22 | ≤243 | 4 | 2.216 | 84*100 |
GNRP33 | 24 | 30 | 26 | 33 | 1103A-33G | ≤210 | 3 | 3.3 | 105*127 |
GNRP50 | 36 | 45 | 40 | 50 | 1103A-33TG1 | ≤212 | 3 | 3.3 | 105*127 |
GNRP65 | 48 | 60 | 52 | 65 | 1103A-33TG2 | ≤211 | 3 | 3.3 | 105*127 |
GNRP73 | 52 | 65 | 58 | 73 | 1104A-44TG1 | ≤207 | 4 | 4.4 | 105*127 |
GNRP88 | 64 | 80 | 70 | 88 | 1104A-44TG2 | ≤213 | 4 | 4.4 | 105*127 |
GNRP103 | 75 | 94 | 82 | 103 | 1006TG1A | ≤210 | 6 | 5.99 | 100*127 |
GNRP150 | 110 | 138 | 120 | 150 | 1006TAG | ≤205 | 6 | 5.99 | 100*127 |
GNRP165 | 120 | 150 | 132 | 165 | 1006TAG2 | ≤205 | 6 | 5.99 | 100*127 |
GNRP225E | 165 | 206 | 180 | 225 | 1306C-E87TAG3 | ≤220 | 6 | 8.7 | 117*136 |
GNRP250E | 180 | 225 | 200 | 250 | 1306C-E87TAG4 | ≤219 | 6 | 8.7 | 117*136 |
GNRP259E | 188 | 235 | 207 | 259 | 1306C-E87TAG5 | ≤221 | 6 | 8.7 | 117*136 |
GNRP275E | 200 | 250 | 220 | 275 | 1306C-E87TAG6 | ≤223 | 6 | 8.7 | 117*136 |
GNRP344E | 250 | 313 | 275 | 344 | 2206C-E13TAG2 | ≤201 | 6 | 14.6 | 137*165 |
GNRP388E | 280 | 350 | 310 | 388 | 2206C-E13TAG2 | ≤198 | 6 | 14.6 | 137*165 |
GNRP450E | 320 | 400 | 360 | 450 | 2206C-E13TAG3 | ≤201 | 6 | 14.6 | 137*165 |
GNRP500E | 360 | 450 | 400 | 500 | 2506C-E15TAG1 | ≤216 | 6 | 15 | 137*171 |
GNRP550E | 400 | 500 | 440 | 550 | 2506C-E15TAG2 | ≤211 | 6 | 15 | 137*171 |
GNRP625E | 450 | 563 | 500 | 625 | 2806A-E18TAG1A | ≤196 | 6 | 18.13 | 145*183 |
GNRP700E | 508 | 635 | 560 | 700 | 2806A-E18TAG2 | ≤203 | 6 | 18.13 | 145*183 |
GNRP800 | 580 | 725 | 640 | 800 | 4006-23TAG2A | ≤199 | 6 | 22.921 | 160*190 |
GNRP900 | 640 | 800 | 720 | 900 | 4006-23TAG3A | ≤200 | 6 | 22.921 | 160*190 |
GNRP1000 | 720 | 900 | 800 | 1000 | 4008-TAG1A | ≤206 | 8 | 30.561 | 160*190 |
GNRP1125 | 818 | 1022 | 900 | 1125 | 4008-TAG2A | ≤208 | 8 | 30.561 | 160*190 |
GNRP1375 | 1000 | 1250 | 1100 | 1375 | 4012-46TWG2A | ≤212 | 12 | 45.482 | 160*190 |
Genset Features:
1. Genuine UK industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine UK Perkins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
- Q: What is the difference between the two class motors and the four-stage motors?
- The number of the most numerous is the relation between the electric frequency and the mechanical speed, n = 120f/P, n is the mechanical speed, f is the electric frequency, and P is the extreme number. But it doesn't have anything to do with "good." A lot of people say very many, large torque, in fact the two are no significant relationship, the poles of three-phase motor torque T = kBr * Bsk is constant, Br is the rotor magnetic field intensity, Bs is produced by the armature magnetic field intensity, * to cross. When you're in the 4 pole, you feel like you have two torque T, and the torque seems to be twice,
- Q: Direct drive motor control mode
- A direct drive motor is an electric motor that does not require a transmission mechanism, which drives the load directly. Normally this type of motor has no output shaft and is mechanically different from other motors. But there is no difference between electromagnetic structures and other motors. There is a box and an unframed simple point which means there is no shell.
- Q: What is the difference between a single phase motor and a two-phase machine?
- Motor has single-phase ac motor and three-phase motor. I haven't heard of a two-phase machine. Are you asking for a positive reverse motor? Three phases are phase modulation. Any two phases are exchanged. C, R, S.
- Q: Why is electric motors not rotating? Everything else is good.
- The voltage should be greater than 36V (the battery is sufficient), and the input line should be checked if there is no voltage. Check the controller to turn the power supply voltage (switching of the red, black), normal voltage in 5 ~ 6 v, if there is no 5 v voltage, unplug the socket, restore 5 v voltage, hall element may be for motor short circuit, if still no 5 v voltage, is used as the controller, the controller should be replaced. First of all, check the speed of adjustment and the opening of the motor hall to have a short circuit.
- Q: What is the difference between explosion-proof motors and ordinary motors?
- Its structural features are: (1) there is a complete ventilation system which does not exist within the motor. (2) the shell and pipe are made of non-combustible materials and have sufficient mechanical strength. (3) the casing and the main pipe are sufficiently large to maintain the positive pressure relative to the outside atmosphere. (4) the motor must have a safety device (e.g., time relay and flow monitor), to ensure adequate ventilation, also must have the shell pressure under voltage automatic protection and alarm device. (5) the door or cover of the enclosure shall be equipped with the power interlock. There is no single series of positive voltage motor series in our country.
- Q: If the speed of a normal motor is adjusted by the frequency converter, the speed can exceed the rated speed, and if the current power is above the rated speed, what is the change in current power
- When the torque is greater than the load, the frequency can reach the limit, higher than the constant power characteristic, and the real-time current is not overrated. The change of motor is just a consideration of the torque
- Q: What is the main difference between the step motor and the ordinary motor?
- Stepper motor and the general difference is mainly lies in the form of the pulse drive (send a pulse control system, can give in a rotary Angle of motor), because of the characteristics of step motor can be combined with modern digital control technology (particularly suitable for mechanical and electrical integration products). However, it is inferior to the traditional closed-loop dc servo motor in the accuracy, speed range and low speed performance of the step motor. It is possible to use stepping motor in an environment where precision is not particularly high, and the step motor can be characterized by simple structure, high reliability and low cost. When used properly, it can even be compared to the performance of dc servo motors.
- Q: What are the characteristics of plateau motors? Why can't the general motors be used for plateau areas
- General motor's normal use of the environment temperature is 5 to 40 degrees, at an altitude of 1000 meters the following, the motor structure design and only meet the needs of the geographical climate conditions, so general motors can not adapt to the plateau region of bad environment.
- Q: Can you use a transducer to control the general motors? Recently, the factory has to renovate two 150 kw electric motors, which were previously controlled by the star delta, and now change the frequency converter, the electric motor is near the stove, the ambient temperature is higher. Please give me your opinion, thank you
- If you don't reload frequently, not reload, you don't have to work long hours at low frequencies, and you have a fan that's basically ok.
- Q: The difference between a two-speed motor and a regular motor
- The difference between a two-speed motor and an ordinary motor: Double speed motor Belong to the speed regulating pole asynchronous motor variant, it is by changing the connection of the stator winding method to change the stator rotating magnetic field pole logarithm, which changes the speed of the motor. The speed of the motor changes the way the winding is connected, which is to change the magnetic poles of the magnetic field to change its speed. Two-speed motor (fan), low speed at ordinary times, sometimes fan on high speed turning, mainly through the following external control circuit switch to change the way the motor coil winding connection.
Send your message to us
Perkins Genset Diesel Generator 48kw To 680kw With Digital Auto-Start Panel
- Loading Port:
- Guangzhou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords