50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine
Quick Detail:
1. 15kva ,60kva 90kva 120kva Perkins diesel engine
2. Leroysomer alternator 230V/400V,3phase Brushless, 4 poles
3. Smartgen digital control panel with ATS
4. 10-hour operation base tank
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRP10 | 7 | 9 | 8 | 10 | 403D-11 | ≤252 | 3 | 1.131 | 77*81 |
GNRP15 | 10 | 13 | 12 | 15 | 403D-15 | ≤264 | 3 | 1.496 | 84*94 |
GNRP23 | 16 | 20 | 18 | 23 | 404D-22 | ≤243 | 4 | 2.216 | 84*100 |
GNRP33 | 24 | 30 | 26 | 33 | 1103A-33G | ≤210 | 3 | 3.3 | 105*127 |
GNRP50 | 36 | 45 | 40 | 50 | 1103A-33TG1 | ≤212 | 3 | 3.3 | 105*127 |
GNRP65 | 48 | 60 | 52 | 65 | 1103A-33TG2 | ≤211 | 3 | 3.3 | 105*127 |
GNRP73 | 52 | 65 | 58 | 73 | 1104A-44TG1 | ≤207 | 4 | 4.4 | 105*127 |
GNRP88 | 64 | 80 | 70 | 88 | 1104A-44TG2 | ≤213 | 4 | 4.4 | 105*127 |
GNRP103 | 75 | 94 | 82 | 103 | 1006TG1A | ≤210 | 6 | 5.99 | 100*127 |
GNRP150 | 110 | 138 | 120 | 150 | 1006TAG | ≤205 | 6 | 5.99 | 100*127 |
GNRP165 | 120 | 150 | 132 | 165 | 1006TAG2 | ≤205 | 6 | 5.99 | 100*127 |
GNRP225E | 165 | 206 | 180 | 225 | 1306C-E87TAG3 | ≤220 | 6 | 8.7 | 117*136 |
GNRP250E | 180 | 225 | 200 | 250 | 1306C-E87TAG4 | ≤219 | 6 | 8.7 | 117*136 |
GNRP259E | 188 | 235 | 207 | 259 | 1306C-E87TAG5 | ≤221 | 6 | 8.7 | 117*136 |
GNRP275E | 200 | 250 | 220 | 275 | 1306C-E87TAG6 | ≤223 | 6 | 8.7 | 117*136 |
GNRP344E | 250 | 313 | 275 | 344 | 2206C-E13TAG2 | ≤201 | 6 | 14.6 | 137*165 |
GNRP388E | 280 | 350 | 310 | 388 | 2206C-E13TAG2 | ≤198 | 6 | 14.6 | 137*165 |
GNRP450E | 320 | 400 | 360 | 450 | 2206C-E13TAG3 | ≤201 | 6 | 14.6 | 137*165 |
GNRP500E | 360 | 450 | 400 | 500 | 2506C-E15TAG1 | ≤216 | 6 | 15 | 137*171 |
GNRP550E | 400 | 500 | 440 | 550 | 2506C-E15TAG2 | ≤211 | 6 | 15 | 137*171 |
GNRP625E | 450 | 563 | 500 | 625 | 2806A-E18TAG1A | ≤196 | 6 | 18.13 | 145*183 |
GNRP700E | 508 | 635 | 560 | 700 | 2806A-E18TAG2 | ≤203 | 6 | 18.13 | 145*183 |
GNRP800 | 580 | 725 | 640 | 800 | 4006-23TAG2A | ≤199 | 6 | 22.921 | 160*190 |
GNRP900 | 640 | 800 | 720 | 900 | 4006-23TAG3A | ≤200 | 6 | 22.921 | 160*190 |
GNRP1000 | 720 | 900 | 800 | 1000 | 4008-TAG1A | ≤206 | 8 | 30.561 | 160*190 |
GNRP1125 | 818 | 1022 | 900 | 1125 | 4008-TAG2A | ≤208 | 8 | 30.561 | 160*190 |
GNRP1375 | 1000 | 1250 | 1100 | 1375 | 4012-46TWG2A | ≤212 | 12 | 45.482 | 160*190 |
Genset Features:
1. Genuine UK industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine UK Perkins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70dba< span="">
Optional:
1. Trailer type
2. Soundproof / water proof
3. ATS (automatic transfer switch)
4. Parallel system
5. Remote system
PMC System:
1. Standard 23 pitch windings avoid excessive neutral current
2. Permanent magnet generator system provides constant excitation under all condition
3. Optional accessories available for easy paralleling with mains or other generators
4. AVR auto voltage regulation, auto exciter, auto adjustment
- Q: If the value of the capacitor on a motor is smaller, it can also be installed in other motors
- The capacitance is ageing and the work is unstable and soon expires.I hope my answer will help you.
- Q: What is the difference between a step motor and an ordinary motor
- Stepper motor and the general difference is mainly lies in the form of the pulse drive (send a pulse control system, can give in a rotary Angle of motor), because of the characteristics of step motor can be combined with modern digital control technology (particularly suitable for mechanical and electrical integration products). However, it is inferior to the traditional closed-loop dc servo motor in the accuracy, speed range and low speed performance of the step motor. It is possible to use stepping motor in an environment where precision is not particularly high, and the step motor can be characterized by simple structure, high reliability and low cost. When used properly, it can even be compared to the performance of dc servo motors.
- Q: How is the servo motor parameter chosen
- Servo motor applied to choose, according to general installation size, torque, rotational speed, optical axis or keyboard, if you need to brake the aspects such as selection, such as the BBF servo motor model HM18-48.0-015 A1D HM18 on behalf of the flange installation dimensions (installation size 60 base number, number 80 stand, stand 80, 110 stand, stand 130 number, 150 stand, stand 180 number, 220 stand HM18 represents 180 stand), 48.0 represents 015 rated torque speed (1000 r - 3000 - r), A1D representative with the brake Upstairs the elder brothers say is to control the mode, be a servo drive thing.
- Q: How do you differentiate the converter motor from the general motors?
- rter, the motor is the same, but the problem of controlling the frequency converter
- Q: Direct drive motor control mode
- So there is no such thing as "the frame type is the control mode of the permanent magnet synchronous motor, the no-frame type is the control mode of dc brushless motor". Perhaps your motor coincided with a particular type of "frame with permanent magnet synchronous motor control mode" or the different type of brushless dc motor control way ". In fact, permanent magnet synchronous motor control method and two kinds of brushless dc motor control method in most cases is one thing, there is not much difference.
- Q: What is the difference between a single phase motor and a two-phase machine?
- Single-phase motor is to use the 220 power supply, three-phase motor is to use the three phase line of power supply, no dual phase motor, only electric welding machine is to use two phase 380 v electricity
- Q: Precautions for water cooled motor
- Pay attention to the smell of water-cooled air-cooled motor, vibration and noise. Winding due to temperature too gao will send insulation focal flavour. Some faults, especially the mechanical failure, will soon be reflected as the vibration and noise, so the smell coke or found abnormal vibration or scratches or the hum of the super-large or other noise, power check immediately. (5) always check the heat of the bearing, the oil leakage, change the lubricating oil regularly, and the roller bearing grease should not exceed 70% of the bearing room volume. (6) of wound rotor type water-cooled air-cooled motor, check the contact between the brush and slip ring, brush wear and spark, such as spark serious must clean up the surface of the collector ring, timely and correct the brush spring pressure. (7) keep water-cooled air-cooled motor internal clean, there is no water, oil and debris fell into internal water-cooled air-cooled motor. Air inlet must be kept clear of water-cooled air-cooled motor.
- Q: The difference between ordinary motor and permanent magnet motor
- There are two different kinds of classifications that you can't compare. Permanent magnet motor is called permanent magnet motor, not permanent magnet (electromagnet) for permanent magnet. Dc motors with direct current, no direct current (alternating current) is ac motor. A permanent magnet can be a dc motor or ac motor (for example, a home breeze fan). In the same way, no permanent magnet can be either a dc motor or ac motor, or even an alternating current.
- Q: The difference between PWM and general motors
- PWM motor is frequency conversion motor, that is, the inverter output waveform is not filtering after PWM wave, ordinary motor generally as a standard, usually sinusoidal waveform, if use frequency converter drive, also need to add after the inverter output filter circuit, or general motors can not stand, fever is serious, but also is frequency conversion motor PWM motor is ok.
- Q: What is the meaning of the motor from cold and cold?
- Self-cooling: the surrounding environment, and the holes in the ends of the cover, reduce the temperature of the motor Forced cooling: other help For example: add a fan to the shaft The channel is designed to reduce the temperature through the flow of cold water The oil in the transformer is cold
Send your message to us
50Hz Genset Diesel Generator 40kw To 600kw With Perkins Engine
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords