Perkins Genset Diesel Generator , 55kva - 950kva Electric Start Generator
- Loading Port:
- Guangzhou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Perkins Genset Diesel Generator , 55kva - 950kva Electric Start Generator
Quick Detail:
1.Perkins Oringal Diesel engine:404d-22tg,1104a-44tg2,2506a-e15tag2
2.AC Alternator Brand:stamford,leroy somer,marathon
3.three phase four wires,50Hz/60hZ
4.deepsea,smartgen Digital auto-start panel
5.open,soundproof,trailer type Optional
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRP10 | 7 | 9 | 8 | 10 | 403D-11 | ≤252 | 3 | 1.131 | 77*81 |
GNRP15 | 10 | 13 | 12 | 15 | 403D-15 | ≤264 | 3 | 1.496 | 84*94 |
GNRP23 | 16 | 20 | 18 | 23 | 404D-22 | ≤243 | 4 | 2.216 | 84*100 |
GNRP33 | 24 | 30 | 26 | 33 | 1103A-33G | ≤210 | 3 | 3.3 | 105*127 |
GNRP50 | 36 | 45 | 40 | 50 | 1103A-33TG1 | ≤212 | 3 | 3.3 | 105*127 |
GNRP65 | 48 | 60 | 52 | 65 | 1103A-33TG2 | ≤211 | 3 | 3.3 | 105*127 |
GNRP73 | 52 | 65 | 58 | 73 | 1104A-44TG1 | ≤207 | 4 | 4.4 | 105*127 |
GNRP88 | 64 | 80 | 70 | 88 | 1104A-44TG2 | ≤213 | 4 | 4.4 | 105*127 |
GNRP103 | 75 | 94 | 82 | 103 | 1006TG1A | ≤210 | 6 | 5.99 | 100*127 |
GNRP150 | 110 | 138 | 120 | 150 | 1006TAG | ≤205 | 6 | 5.99 | 100*127 |
GNRP165 | 120 | 150 | 132 | 165 | 1006TAG2 | ≤205 | 6 | 5.99 | 100*127 |
GNRP225E | 165 | 206 | 180 | 225 | 1306C-E87TAG3 | ≤220 | 6 | 8.7 | 117*136 |
GNRP250E | 180 | 225 | 200 | 250 | 1306C-E87TAG4 | ≤219 | 6 | 8.7 | 117*136 |
GNRP259E | 188 | 235 | 207 | 259 | 1306C-E87TAG5 | ≤221 | 6 | 8.7 | 117*136 |
GNRP275E | 200 | 250 | 220 | 275 | 1306C-E87TAG6 | ≤223 | 6 | 8.7 | 117*136 |
GNRP344E | 250 | 313 | 275 | 344 | 2206C-E13TAG2 | ≤201 | 6 | 14.6 | 137*165 |
GNRP388E | 280 | 350 | 310 | 388 | 2206C-E13TAG2 | ≤198 | 6 | 14.6 | 137*165 |
GNRP450E | 320 | 400 | 360 | 450 | 2206C-E13TAG3 | ≤201 | 6 | 14.6 | 137*165 |
GNRP500E | 360 | 450 | 400 | 500 | 2506C-E15TAG1 | ≤216 | 6 | 15 | 137*171 |
GNRP550E | 400 | 500 | 440 | 550 | 2506C-E15TAG2 | ≤211 | 6 | 15 | 137*171 |
GNRP625E | 450 | 563 | 500 | 625 | 2806A-E18TAG1A | ≤196 | 6 | 18.13 | 145*183 |
GNRP700E | 508 | 635 | 560 | 700 | 2806A-E18TAG2 | ≤203 | 6 | 18.13 | 145*183 |
GNRP800 | 580 | 725 | 640 | 800 | 4006-23TAG2A | ≤199 | 6 | 22.921 | 160*190 |
GNRP900 | 640 | 800 | 720 | 900 | 4006-23TAG3A | ≤200 | 6 | 22.921 | 160*190 |
GNRP1000 | 720 | 900 | 800 | 1000 | 4008-TAG1A | ≤206 | 8 | 30.561 | 160*190 |
GNRP1125 | 818 | 1022 | 900 | 1125 | 4008-TAG2A | ≤208 | 8 | 30.561 | 160*190 |
GNRP1375 | 1000 | 1250 | 1100 | 1375 | 4012-46TWG2A | ≤212 | 12 | 45.482 | 160*190 |
Genset Features:
1. Genuine UK industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine UK Perkins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
- Q: How do ordinary motors achieve precise positioning
- Ordinary motors can be accurately positioned through a series of circuits. Specific as follows: In action slider side low add a micro switch, micro switch control an intermediate relay, in the middle of the normally closed contact is broken the power of the motor, and at the same time delay relay through 3 s, the use of time relay normally open point back to the motor power supply. The highest point also can add a microdynamic switch the principle is the same! This completes the basic positioning control circuit and the lowest cost.
- Q: How do you differentiate the converter motor from the general motors?
- rter, the motor is the same, but the problem of controlling the frequency converter
- Q: Which is good for the washing machine series motor and general motors?
- Principle of general motors: the direction of force of conductor is determined by the left hand. This pair of electromagnetic force formed on the armature a torque, the torque in rotary motor is called electromagnetic torque, torque direction is counterclockwise, trying to make the armature counterclockwise rotation. If the electromagnetic torque can overcome the armature resistance torque (for example, caused by friction resistance torque and other load torque) and the armature can spin counterclockwise direction.
- Q: What is the difference between a single phase motor and a two-phase machine?
- Single-phase motor is to use the 220 power supply, three-phase motor is to use the three phase line of power supply, no dual phase motor, only electric welding machine is to use two phase 380 v electricity
- Q: The difference between pump motor and general motor?
- The oil pump motor is basically the same as normal motor, the difference is that the oil pump motor shaft is set up with the flange and the interface of the oil pump, which is convenient for the oil pump.
- Q: How do you think a motor is an ordinary motor or a servo
- The step motor is an ordinary open-loop motor, the back end of the servo motor is an encoder device, the motor with the coder feedback. Ordinary stepper motor speed is generally around 300-600, the speed of the servo motor, generally can reach 3000 turn above, higher precision, but the cost is much higher than ordinary servo stepper motor. Now our company has developed a new step servo motor based on the basic step motor and servo motor. The cost is low, the price ratio is high, the coder feedback is accurate, listen to the friend to say to use very good!
- Q: What is the difference between a three-phase asynchronous motor and a regular motor?
- Three-phase asynchronous motor cooling fan is fixed on the motor shaft, the same as the rotation speed of the motor, low frequency is run, the fan is running at low speed, the cooling capacity drops greatly, the heat generated by the motor can't send out, serious when burning motor. The structure and pressure capacity of the inverter motor are specially designed to accommodate high speed and high harmonics. Motor has the branch of general motor and frequency conversion motor, called main appearance is different from ordinary motor frequency conversion motor frequency conversion motor is packed with centrifugal fan forced cooling, this ensures the motor at low frequency and high frequency heat dissipation is good, and frequency conversion motor internal structure can adapt to the high frequency operation of specific working frequency range see nameplate. General motors generally allow only running under 50hz.
- Q: What are the characteristics of plateau motors? Why can't the general motors be used for plateau areas
- General motor's normal use of the environment temperature is 5 to 40 degrees, at an altitude of 1000 meters the following, the motor structure design and only meet the needs of the geographical climate conditions, so general motors can not adapt to the plateau region of bad environment.
- Q: My electric motor with riding a motor won't turn, idling did not move, I thought that the controller has broken a new motor does not turn other are thoroughly headlight electricity for electric machine does not move
- I thought the controller broke a new motor and didn't turn????????? It's strange that the controller has broken a new motor. Are you in the water?
- Q: What is the difference between the riot motor and the ordinary motor? How does it work differently from ordinary motors? Is it possible to be overloaded with ordinary motors? Please help me, thank you.
- Special motor is a kind of fuzzy concept for brushless dc motor and ac asynchronous motor. Traditionally, all motors are called special motors except for brushless dc motors and ac asynchronous motors. Special motors are not used for special occasions.
Send your message to us
Perkins Genset Diesel Generator , 55kva - 950kva Electric Start Generator
- Loading Port:
- Guangzhou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords