Quick Detail:
 

1.Cummins Industrial Diesel Engine :6bt5.9-g2,6ctaa8.3-g2,6ltaa8.9-g2

2.Machinery or electronic governing

3.AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

4.English interface,LED screen and touch buttons

5.Automatic transfer switch

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G2

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G2

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G2

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G2

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G2

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190

 


Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.

Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Super Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

Water Cooled Cummins Genset Diesel Generator 35kw To 680kw With 3 Phase

 

Q:What is the difference between explosion-proof motors and ordinary motors?
Its structural features are: (1) there is a complete ventilation system which does not exist within the motor. (2) the shell and pipe are made of non-combustible materials and have sufficient mechanical strength. (3) the casing and the main pipe are sufficiently large to maintain the positive pressure relative to the outside atmosphere. (4) the motor must have a safety device (e.g., time relay and flow monitor), to ensure adequate ventilation, also must have the shell pressure under voltage automatic protection and alarm device. (5) the door or cover of the enclosure shall be equipped with the power interlock. There is no single series of positive voltage motor series in our country.
Q:What's the difference between a step motor and a brushless motor?
The consistent place for stepping motor and brushless motor is the need to move through the electrical pulse. But brushless motor without stepper motor design theory so only to a certain extent, the same properties, many ways to do less than precise control of stepping motor.
Q:What is the meaning of the motor from cold and cold?
Motor self-cooling refers to the wind blade of the rotor, which starts cooling during the operation of the motor. The motor is cooled by an electric motor plus cooling fan. Normal three-phase ac asynchronous motors are used for cold, and it is very cold when it is unable to heat the electric motors and heat the heat. Such as frequency conversion motor, dc motor, etc., normally use force cooling.
Q:Does the frequency conversion machine speak louder than the ordinary motor?
No, only when the frequency is low. It's basically the same as a normal machine in 10HZ.I hope my answer will help you
Q:The amount of the machine is doubled, all the other motors are unchanged, the rated torque and the speed change.
Do you specify the thickness of the laminated rotor? Laminated thickness increase and will not affect the speed (speed and logarithmic and frequency) and rated torque will be slightly ascending, maximum torque, rated current decreases.
Q:The difference between pulse motor and servo motor
The pulse motor you're talking about should be a step motor, right? If it is a step motor, it is also a kind of servo motor. He is the corresponding step Angle for each pulse. The motor speed is proportional to the frequency of the pulse, and the rotation Angle is proportional to the number of pulses. One way to tell the difference is: you're asking the difference between apples and fruit, because apples are fruit. But it's just one of many fruits Well, I'm not saying that stepping into the motor is a kind of servo motor Servo motor includes: step motor, dc servo motor, ac servo motor, linear motor, etc. So let me give you the example above.
Q:In the case of ac motor, the voltage will be higher or lower in constant voltage, which will affect the motor.
The frequency can affect the speed of the motor, the frequency is high, the motor speed is fast, the frequency is low, the motor speed is slow. The increase of frequency makes the electric motor feel resistant to increase, the voltage is high, the current decreases if the voltage is constant. The decrease of the frequency of the power supply makes the motor feel less resistant, the voltage is low, and if the voltage is constant, the current increases, and the magnetic saturation is possible.
Q:What is the cause of the overheating of the servo motor
4: the inner hole of the bearing is eccentric, and the shaft is wiped. : 5: the motor ends or the bearing cover are not flat; 6: there is no calibration of the coupling between the motor and the load, or the belt is too tight; 7: the bearing clearance is too large or too small; The motor shaft bends.
Q:A 2.2 KW motor will require a lot of electricity a day
It is not accurate to calculate simply because you are not considering the load rate of the motor, and the load rate of the pump is less than 75%. The most accurate method is to install the meter.
Q:Can variable frequency control motor be used as a general motor?
The variable frequency speed regulating motor is a three-phase asynchronous motor with a simple squirrel-cage and a cooling fan In other words, the variable speed motor is more strict than the general motor, so there is no problem with the general motors

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords