Specifications:
1, 20kw ~250kw Weichai power generator
Weichai diesel engine is basic on the introduction of foreign(Ricardo Britain) advanced diesel engine technology and developed which is characterized by economical fuel consumption,low noise,powerful,stable operation and reliable performance.
2,Main specification
a,3-Phase, 50Hz@1500RPM, 400/230V (Also Can Be Made According To Customers’ Special Requirements)
b,12V/24V DC start motor and storage battery
c,Brushless, Self-excited, IP21-23, insulation class H alternator
d, 40°C radiator as standard, 50°C is optional
e,Key start panel control system as standard, digital auto-start panel is optional
f,All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load, 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
3,Data of diesel Generator Set
Prime Power | 20kw-250kw | Standby Power | 22kw-275kw |
Rated Speed | 1500rpm | Output Frequency | 50hz/60hz |
Phase | 3 | Rated Voltage | 400v |
Engine Brand | Weichai | Alternator Brand | Stamford |
Fuel Consumption | 4L-200L | Fuel Tank capacity | 8 hours |
Voltage Regulation Rate | ≤±1% | Random Voltage Rate | ≤±1% |
Frequency Regulation Rate | ≤±5% | Random Frequency Variation | ≤±0.5% |
4,Engine Specification
Genset Model | Prime Powe | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRW-28 | 20 | 25 | 22 | 28 | K4100D | 236 | 4 | 3.6 | 100*115 |
GNRW-34 | 24 | 30 | 27 | 34 | K4100D | 236 | 4 | 3.6 | 100*115 |
GNRW-41 | 30 | 38 | 33 | 41 | K4100D | 236 | 4 | 3.6 | 100*115 |
GNRW-55 | 40 | 50 | 44 | 55 | K4100ZD | 238 | 4 | 3.6 | 100*115 |
GNRW-69 | 50 | 63 | 55 | 69 | R4105ZD | 238 | 4 | 4.3 | 105*115 |
GNRW-104 | 75 | 94 | 83 | 104 | R6105ZD | 238 | 6 | 6.5 | 105*115 |
GNRW-125 | 90 | 113 | 100 | 125 | R6105ZLD | 238 | 6 | 6.5 | 105*115 |
GNRW-138 | 100 | 125 | 110 | 138 | R6105AZLD | 238 | 6 | 6.7 | 105*115 |
GNRW-165 | 120 | 150 | 132 | 165 | R6105IZLD | 238 | 6 | 6.7 | 105*115 |
GMRW-206 | 150 | 188 | 165 | 206 | 6113AZLD | 238 | 6 | 7.5 | 113*115 |
5,Alternator Specification
Alternator Brand | Stamford,Engga,Mecc-alte,Marathon ... |
Exciter Type | Brushless, Self-excited |
Rated Speed | 1500/1800rpm |
Rated Frequency | 50/60hz |
Phase | three or single |
Rated Voltage | 400V (Available with customer requirements) |
Power | 0.8 |
Voltage Adjust Range | ≥5% |
Protection Grade | IP22 |
Insulation Grade | H |
6,Digital Control Panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
7. Accessories
1) Standard accessories: Standard 40 radiator mounted on skid, Common steel frame, circuit breaker, damper, exhaust silencer, flexible pipe, battery and connecting wires, Standard tools kit, operation manual and document.
2) Optional accessories: Engine coolant and oil heater, alternator space heater, cooling for heat exchanger, communication interface, battery charger by main supply, daily fuel tank, ATS and paralleling system, soundproof canopy and moving trailer.
- Q: What kind of fan is explosion-proof motor
- First of all, should be clear is general explosion-proof, still be explosion-proof of coal grade. Explosion-proof motors, if applied to EXDI, should be done according to 3836.2,
- Q: How does the motor stop
- The motor and the emergency stop button are added in the control circuit of the motor. Methods: Connect the frequent closed contact of the emergency stop button to the start loop of the contactor. It's usually in front of the stop button. This way the control circuit stops working when pressing the emergency stop button.
- Q: What is the difference between a three-phase asynchronous motor and a regular motor?
- Three-phase asynchronous motor has high efficiency, energy saving, low noise, small vibration, and the advantages of reliable performance, can make using of the drive for different mechanical: such as fan, compressor, water pump, crusher, cutting machine and other equipment, and is available for coal mining, mechanical industry, power plants and various industrial and mining enterprises as a prime mover. Thank you for your reference. I hope I can help you.
- Q: The difference between the frequency converter and the ordinary motor
- Variable frequency motor is more than ordinary motor, and the specific advantages of frequency conversion motor are: 1, have the start function The resistance of stator and rotor is reduced by electromagnetic design Adjust to the constant speed change under different working conditions 4, to some extent energy saving
- Q: Does the frequency conversion machine speak louder than the ordinary motor?
- This is not necessarily, the power of the motor size, also related to the noise of the motor itself, but in the case of the same parameters, the inverter will make voice be larger than ordinary motor, because through the inverter output waveform directly contains a large number of higher harmonic,
- Q: Can you use a transducer to control the general motors? Recently, the factory has to renovate two 150 kw electric motors, which were previously controlled by the star delta, and now change the frequency converter, the electric motor is near the stove, the ambient temperature is higher. Please give me your opinion, thank you
- If you don't reload frequently, not reload, you don't have to work long hours at low frequencies, and you have a fan that's basically ok.
- Q: What is the difference between the riot motor and the ordinary motor? How does it work differently from ordinary motors? Is it possible to be overloaded with ordinary motors? Please help me, thank you.
- The generator is the same as the electric motor, which runs on the motor. The drive is driven by the rotor, and the magnetic field cutting stator winding inducs the electromotive force to become a generator.
- Q: Why does the direct start-up of high power motors affect the voltage of the grid
- Because of the asynchronous motor starting, the rotor has not turned up, the stator rotating magnetic field cutting speed relative to the rotor conductors, in rotor induction electric potential is very big, so the current is very big, if starting directly from grid, starting current can reach 4 to 7 times the rated current, and is the most current inductive current, this would have had a big impact on the grid: 1) the large starting current will be produced on the transmission line, the larger voltage drop; 2) because so much of the starting current, most of it is a perceptual current, will cause a demagnetization effect on the grid, and will also cause the grid voltage to fluctuate.
- Q: What is the electric motor in the car seat?
- The simple point is the signal line, and the seat motor is usually the synchronous motor.The two power lines are the control motors, and those three are the controllers that control the rotation and inversion of the motors
- Q: The difference between a two-speed motor and a regular motor
- The difference between a two-speed motor and an ordinary motor: Double speed motor Belong to the speed regulating pole asynchronous motor variant, it is by changing the connection of the stator winding method to change the stator rotating magnetic field pole logarithm, which changes the speed of the motor. The speed of the motor changes the way the winding is connected, which is to change the magnetic poles of the magnetic field to change its speed. Two-speed motor (fan), low speed at ordinary times, sometimes fan on high speed turning, mainly through the following external control circuit switch to change the way the motor coil winding connection.
Send your message to us
Weichai Genset Diesel Power Generator Set 20kw1500RPM 50Hz
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords