• Power Genset Diesel Generator 30kw - 600kw With Cummins Engine System 1
  • Power Genset Diesel Generator 30kw - 600kw With Cummins Engine System 2
Power Genset Diesel Generator 30kw - 600kw With Cummins Engine

Power Genset Diesel Generator 30kw - 600kw With Cummins Engine

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Power Genset Diesel Generator 30kw - 600kw With Cummins Engine

 

 

Quick Detail:

1.Cummins Industrial Diesel Engine :4BTA3.9-G2,6BTA5.9-G2,KTA19-G3

2.Electronic Governor,Water Cooled

3.Original Stamford AC Alternator:UCI224E ,UCI274D,UCI274H

4.English interface,LED screen and touch buttons controller

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G2

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G2

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G2

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G2

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G2

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190


 

Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.

Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Super Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

Q: Does the motor have a good brush or no brush?
Brush refers to brush, brush dc motor, brush and commutator of the friction and unable to avoid sparks, but relatively speaking, simple control circuit. So, for control, there is a good control of the brush. But for users, a brushless motor clearly has a long life.
Q: What is the structural difference between a two-speed motor and a regular motor
Most of speed regulating pole change motor for squirrel-cage rotor motor, its structure is similar to the basic series three-phase asynchronous squirrel cage motor, now the domestic production of two, three, four speed 3 classes. Common asynchronous motor rotor speed formula: n = 60f/p, ordinary motor has only one speed.
Q: What is the difference between a single phase motor and a two-phase machine?
Motor has single-phase ac motor and three-phase motor. I haven't heard of a two-phase machine. Are you asking for a positive reverse motor? Three phases are phase modulation. Any two phases are exchanged. C, R, S.
Q: Why is electric motors not rotating? Everything else is good.
Electric common failures and troubleshooting methods instrument display is normal, motor does not turn the cause of the problem: (1) brake the damage judgment (2) speed control to turn the damage judgment damage judgment, (4) (3) motor controller damaged troubleshooting: (1) remove the brake handle socket (normally open type brake handle). If the motor operates, the brake should be replaced. Turn the source 5V voltage to normal, check the signal voltage, turn the transfer, the signal voltage should be in 0.8 ~ 4.2 V from low to high. If the voltage is not changed and is less than 1V, then the fault or turn will be short-circuited. If the voltage is greater than 1V and the change is normal, the signal (yellow, green and blue) is detected. If the voltage of the three-phase hall signal line is 5V and is in good contact, the motor hall is damaged and the motor or motor hall elements should be replaced.
Q: The difference between brushless dc motor and plain dc motor, where is its advantage
Two contrast ordinary, brushless dc motor has the advantage of the brushless dc motor: 1, brushless dc motors have higher efficiency and efficiency can be as high as more than 70%, significantly higher than the ordinary brushless dc motor are the efficiency of about 40%. The life of dc brushless motor can be up to 10,000 hours, whereas the average brush dc motor has a life span of less than 1000 hours. The noise of the dc brushless motor and the electromagnetic interference are very small, and the noise and electromagnetic interference of the common brush dc motor are very large. 4, brushless dc motor can be precise control, customer variable voltage and variable frequency control, the integrated drive circuit boards of hall element position signal output, brushless motor can use this position signal for precise control, precision as stepper motor, and much more life and high efficiency.
Q: What is the main difference between the step motor and the ordinary motor?
Step motor is pulse control, one pulse is a step; General electric motor is called induction motor, which is controlled by analog quantity, and the electricity is transferred.
Q: Does the motor swing around?
The motor bearing is out of question, causing the left and right oscillation.I hope my answer will help you.
Q: Why does the direct start-up of high power motors affect the voltage of the grid
The ac motor starts with a current of 5 to 7 times the rated current. The effect of the high power motor directly on the voltage of the grid; The main consideration is that a large start current will reduce the voltage of the grid and cause a ripple effect. Normally, the power grid transformer capacity is over 180kVA, and the power of the motor is below 7kW. At present 4-100kw motor multi-purpose delta voltage drop starting..
Q: The amount of the machine is doubled, all the other motors are unchanged, the rated torque and the speed change.
Motor iron core thickness (including the length of the rotor) doubled, the perimeter of the coil as growth also long (about a third or higher), wire resistance will increase, in addition to the rotating speed is constant, rated power (including torque) will be reduced.
Q: Can a converter control a general electric machine
Yes, with schneider's AV61 series, which is easy to control, its speed and working hours are adjustable. I used it. I promise.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords