Quick Detail:
1.Cummins Industrial Diesel Engine :4BTA3.9-G2,6BTA5.9-G2,KTA19-G3
2.Electronic Governor,Water Cooled
3.Original Stamford AC Alternator:UCI224E ,UCI274D,UCI274H
4.English interface,LED screen and touch buttons controller
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRC30 | 20 | 25 | 24 | 30 | 4B3.9-G | ≤229 | 4 | 3.9 | 102*120 |
GNRC35 | 24 | 30 | 28 | 35 | 4BT3.9-G2 | ≤214 | 4 | 3.9 | 102*120 |
GNRC56 | 40 | 50 | 45 | 56 | 4BTA3.9-G2 | ≤215 | 4 | 3.92 | 102*120 |
GNRC63 | 45 | 56 | 50 | 63 | 4BTA3.9-G2 | ≤215 | 4 | 3.92 | 102*120 |
GNRC70 | 50 | 63 | 56 | 70 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC106 | 78 | 98 | 85 | 106 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC125 | 90 | 113 | 100 | 125 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC150 | 104 | 130 | 120 | 150 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC165 | 120 | 150 | 132 | 165 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC200 | 140 | 175 | 160 | 200 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC225 | 160 | 200 | 180 | 225 | 6CTAA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC275 | 200 | 250 | 220 | 275 | 6LTAA8.9-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC313 | 220 | 275 | 250 | 313 | NTA855-G1A | ≤206 | 6 | 14 | 140*152 |
GNRC350 | 250 | 313 | 275 | 350 | NTA855-G2 | ≤207 | 6 | 14 | 140*152 |
GNRC400 | 280 | 350 | 310 | 400 | NTA855-G4 | ≤208 | 6 | 14 | 140*152 |
GNRC413 | 300 | 375 | 330 | 413 | NTAA855-G7 | ≤206 | 6 | 14 | 140*152 |
GNRC450 | 320 | 400 | 360 | 450 | NTAA855-G7A | ≤206 | 6 | 14 | 140*152 |
GNRC500 | 360 | 450 | 400 | 500 | KTA19-G3 | ≤203 | 6 | 18.9 | 159*159 |
GNRC550 | 400 | 500 | 440 | 550 | KTA19-G4 | ≤203 | 6 | 18.9 | 159*159 |
GNRC605 | 440 | 550 | 484 | 605 | KTAA19-G6 | ≤204 | 6 | 18.9 | 159*159 |
GNRC625 | 450 | 563 | 500 | 625 | KTAA19-G7 | ≤204 | 6 | 18.9 | 159*159 |
GNRC700 | 500 | 625 | 560 | 700 | KTA38-G | ≤206 | 12 | 37.8 | 159*159 |
GNRC712 | 520 | 650 | 570 | 712 | QSK19-G3 | ≤206 | 6 | 19 | 159*159 |
GNRC800 | 580 | 720 | 640 | 800 | KTA38-GA | ≤209 | 12 | 37.8 | 159*159 |
GNRC825 | 600 | 750 | 660 | 825 | KTA38-G2 | ≤210 | 12 | 37.8 | 159*159 |
GNRC888 | 640 | 800 | 710 | 888 | KTA38-G2B | ≤210 | 12 | 37.8 | 159*159 |
GNRC975 | 720 | 900 | 780 | 975 | KTA38-G2A | ≤210 | 12 | 37.8 | 159*159 |
GNRC1075 | 800 | 1000 | 860 | 1075 | KTA38-G5 | ≤202 | 12 | 37.8 | 159*159 |
GNRC1375 | 1000 | 1250 | 1100 | 1375 | KTA50-G3 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1375 | 1100 | 1375 | 1310 | 1650 | KTA50-G8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1650 | 1200 | 1500 | 1340 | 1675 | KTA50-GS8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1675 | 1350 | 1688 | 1500 | 1875 | QSK60-G3 | ≤215 | 16 | 60 | 159*159 |
GNRC1875 | 1500 | 1875 | 1650 | 2063 | QSK60-G3 | ≤215 | 16 | 60 | 159*190 |
GNRC2063 | 1600 | 2000 | 1800 | 2250 | QSK60-G4 | ≤215 | 16 | 60 | 159*190 |
Genset Features:
1. Genuine Commins industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine Cummins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Super Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70DBA
- Q: Which is good for common motor and induction motor?
- Induction motor, also called "asynchronous motor, the rotor put in a rotating magnetic field, under the effect of rotating magnetic field, to obtain a rotational torque, thus the rotor rotation. The rotor is a rotating conductor, usually in a squirrel-cage. It was invented by electrical engineer nikola tesla in 1887.
- Q: How does the motor stop
- Emergency stop switch: just for a switch, usually use red or yellow mushroom head button, plays the role of the emergency stop in control circuit, so that the emergency stop switch The first method, which is also the usual addition, sets a closed contact switch in tandem with the motor's contactor coil circuit. It is possible to power the contactor in the job, so that the electric motor that runs through the contactor is lost to the purpose of the emergency stop. Method 2: there are also some three phase power switch (motor power) with control contact. Use the emergency stop switch to control the three-phase power switch. The electric motors that are run by the contactor are lost to the purpose of an emergency stop. The first is gm, the second is more expensive. Supplement: Is three motor, there is a knife, and later began to work, I have a red emergency stop switch, I'd like to know more things, so pick up to press the machine stop? You can buy another contactor. Follow the first method.
- Q: The advantage of the pole motor relative to the ordinary motor
- Many choices meet all kinds of user requirements with heat sensitive resistance Adopt optimized design, have high efficiency, can produce considerable energy saving effect The installation of anti-dust sealing ring, tropical, oil-proof sealing ring, oil filling, special shaft extension, special flange etc
- Q: Direct drive motor control mode
- A direct drive motor is an electric motor that does not require a transmission mechanism, which drives the load directly. Normally this type of motor has no output shaft and is mechanically different from other motors. But there is no difference between electromagnetic structures and other motors. There is a box and an unframed simple point which means there is no shell.
- Q: Is the servo motor to be used as a common motor?
- Due to the overload ability of servo motor, the rated torque of servo motor can be determined by reference to 1/3 of the output torque of the motor.
- Q: Is permanent magnet power saving?
- Ordinary motors require no work to build a magnetic field, and ordinary generators require a dc to create a magnetic field. Permanent magnet motors, whether motors or generators, need no work or dc to create a magnetic field. Permanent magnet motor loss, low efficiency, high cost, only for small power or special occasion.
- Q: How is the rated current of the three-phase machine calculated?
- Three-phase motor power P = 1.732 UIcos phi, cos phi (power factor) between 0.7 and 0.95, the greater the power of the motor, the greater the power factor, which can be evaluated at 0.85. So I = P/(1.732 * U * cos phi) = 4800 / (1.732 * 440 * 0.8) = 1.732 A, 11.5 A you say may be the whole compressor power or are you using current meter measuring current, if the current meter measurement, so the motor is overload. Voltage is 440 v, can know you this motor is not domestic, domestic general is 380 (400 v), rated 400 v voltage can be used in our country, of course, because the motor is a range of voltage, rated voltage 400 v motor between 360-440 - v can be used. In China there is 440 v, you said general voltage is 380 v, 440 v rated voltage, so when calculating the electric current cannot use the above data, and should change the 440 to 440, the calculated current is 9.1 A. Here's a rough calculation, because 1.732 * 380 * 0.8 = 520, close to 500, so under the three-phase 380V voltage, Current I = P (kilowatt) / 2.
- Q: What is the difference between a speed reducer and a regular motor?
- Deceleration motor called gear motors, are modular combination, at the same time the output torque, 6 (output synchronous speed 1000 RPM), 8 (output synchronous speed 750 RPM), so through the gears or other institutions such as cycloid motor droop down, and the output of the motor speed or torque can meet the actual requirements, the most commonly used the four pole motor, the equipment is used in speed is generally small, motor, the higher the number, the more expensive, general motors is commonly used 4 (output synchronous speed 1500 RPM), is the combination of reducer and motor, gear motor.
- Q: There is a difference between the electric motor and the other motors
- So if the sine wave motor, as the name suggests, changes the square wave to a sine wave.I hope my answer will help you.
- Q: What are the characteristics of plateau motors? Why can't the general motors be used for plateau areas
- Plateau motor motivated than other plateau powerful allowance, anti-aging, customize electromagnetic scheme according to different altitudes good heat dissipation, antifreeze die condensation etc. General motors is designed at an altitude of 1000 the following: including motor insulation level is low, the plateau thin air cooling no ordinary motor can't satisfy the, sand big strong ultraviolet radiation with a large temperature difference between day and night motor easy internal condensation, aging fast ordinary can't satisfy the... In general, ordinary electric motors can produce fever, condensation, low power, outdoor motor, etc
Send your message to us
Power Genset Diesel Generator 30kw - 600kw With Cummins Engine
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords