• Truck / Trailer Genset Diesel Generator500kva  Perkins With AMF System 1
  • Truck / Trailer Genset Diesel Generator500kva  Perkins With AMF System 2
Truck / Trailer Genset Diesel Generator500kva  Perkins With AMF

Truck / Trailer Genset Diesel Generator500kva Perkins With AMF

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

30kva to 500kva Trailer Diesel Generator

Specifications:

Trailer Generator with Turn-table

1. Standard: GB/T2819-1995

2. Single Axle and Double Axle Wheels is available.

3. Heavy Duty Reinforced M.S Chassis, with 8 hours base fuel tank

4.High Strength, impact-resistance, anti-deformation

5. Exclusive water resistance structure, inspection windows, maintenance door in each side

6. Flexible connection lug design insure excellent buffer performance

7. Max. workable Speed 40 km/hr

 

Engine Features:

1. World most famous brand diesel engine: Cummins.Perkins . Doosan. etc

2. Mufti-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

 

Soundproof/Slient Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and safety

6. 1m<80dB/7m<70dB/68dB

  

Control Panel Features:

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

 

Warranty policy

Guarantee for one year or 1000 hours whichever reach first from ex-factory date. During the guarantee period, Genor will provide the free easy-damageable spare parts of diesel engine caused by our quality of production or raw material. After expiration, Genor provides cost spare parts maintenance of gensets.

Truck / Trailer Genset Diesel Generator500kva  Perkins With AMF

Truck / Trailer Genset Diesel Generator500kva  Perkins With AMF

Truck / Trailer Genset Diesel Generator500kva  Perkins With AMF

 

Q: Does the motor have a good brush or no brush?
Carbon brush: carbon brush motor or generator or other fixed part of the rotating machinery and rotational part between energy or signal transmission device, it usually is made of pure carbon and solidifier, appearance is generally square, card on the metal stents, there is a spring pressed it on the shaft, such as oil drilling is completed, need to be tested, from wellbore put instrument, is through the carbon brush will signal from rotating parts (outsourcing wire cable reel) to the ground of the instrument
Q: If the value of the capacitor on a motor is smaller, it can also be installed in other motors
The capacitance is ageing and the work is unstable and soon expires.I hope my answer will help you.
Q: What is the difference between a three-phase asynchronous motor and a regular motor?
Torque motor: a special motor with soft mechanical properties and wide speed range. This motor is not powered by constant power output but by constant torque output. Torque motor includes: dc torque motor, ac torque motor, and brushless dc torque motor. Difference: torque motor is to in the case of lower speed without changing the output torque, motor speed when lowering power supply voltage drops, but the output torque constant, current is the same. Ordinary motors cannot be slowed down by reducing pressure, which will cause the output torque to decrease and the current increase, which will burn the motor. Change frequency converter control: to confirm the torque motor that is controlled is ac asynchronous motor or synchronous motor because the frequency converter is used on ac. It is also important to confirm that the maximum current of the frequency converter is greater than or equal to the current of the torque motor, since the torque motor is able to work in a blocked state.
Q: What is the difference between a general motor and a high-speed motor?
The bearing of high speed motor is wear-resisting, so some high-speed motor USES liquid bearing or air bearing, so that the rotor does not have direct contact with the stator.
Q: The difference between the frequency converter and the ordinary motor
The difference between the frequency conversion motor and the ordinary motor is that the converter motor has no cooling fan, and it needs to be cooled by the fan. Ordinary motors rely on their own fans for heat dissipation, and running maintenance is relatively simple.
Q: The difference between plateau motor and ordinary motor
An increase in altitude causes a decrease in insulation intensity: the insulation intensity of an electric machine is reduced by 8 to 15 percent per 1000 meters, so the insulation strength of the motor is improved.
Q: Can variable frequency control motor be used as a general motor?
The variable frequency speed regulating motor is a three-phase asynchronous motor with a normal squirrel-cage, and a cooling fan, In other words, the variable speed motor is more strict than the general motor, so there is no problem with the general motors. Variable frequency control motor is a general term for the motor that is driven by a frequency converter. Actually designed for frequency converter motor for frequency conversion motor, the motor can be realized by the driving of the frequency converter different rotational speed and torque, to adapt to the demand of load change. Frequency conversion motor by traditional squirrel-cage motor development, changed the traditional motor fan to fan, independence and improve the performance of the insulation of the motor winding. In the case of low power and frequency, the ordinary squirrel cage motor can be used instead of the normal working frequency.
Q: How does the heat of dc motor control
First of all, you want to let us know whether you have a brush or a brush before you can determine if your fever is likely to be caused by what
Q: What is the cause of the overheating of the servo motor
1: too much or too little. 2: the oil is not good to contain impurities; 3: the bearing and the shaft neck or the cover shall be mismatched (too loose or too tight);
Q: What is the electric motor in the car seat?
The two lines are the wires of the motor rotor, and the three lines are the line of the motor controller (the seat control switch is connected to the controller of the seat motor to be controlled before and after the motor is controlled).

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords