Cummins Genset Diesel Generator , 30kva to 600kva Power Generator
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Cummins Diesel Engine:4BTA3.9-G2,6BT5.9-G2,NTAA855-G7A
2. AC alternator: Leroy Somer, Stamford, Marathon
3. 10-hour operation base tank
4. CE Certificate
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRC30 | 20 | 25 | 24 | 30 | 4B3.9-G | ≤229 | 4 | 3.9 | 102*120 |
GNRC35 | 24 | 30 | 28 | 35 | 4BT3.9-G | ≤214 | 4 | 3.9 | 102*120 |
GNRC56 | 40 | 50 | 45 | 56 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
GNRC63 | 45 | 56 | 50 | 63 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
GNRC70 | 50 | 63 | 56 | 70 | 6BT5.9G1 | ≤215 | 6 | 5.88 | 102*120 |
GNRC106 | 78 | 98 | 85 | 106 | 6BT5.9G | ≤215 | 6 | 5.88 | 102*120 |
GNRC125 | 90 | 113 | 100 | 125 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC150 | 104 | 130 | 120 | 150 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
GNRC165 | 120 | 150 | 132 | 165 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC200 | 140 | 175 | 160 | 200 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC225 | 160 | 200 | 180 | 225 | 6CTAA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC275 | 200 | 250 | 220 | 275 | 6LTAA8.9-G2 | ≤210 | 6 | 8.3 | 114*135 |
GNRC313 | 220 | 275 | 250 | 313 | NTA855-G1A | ≤206 | 6 | 14 | 140*152 |
GNRC350 | 250 | 313 | 275 | 350 | NTA855-G2 | ≤207 | 6 | 14 | 140*152 |
GNRC400 | 280 | 350 | 310 | 400 | NTA855-G4 | ≤208 | 6 | 14 | 140*152 |
GNRC413 | 300 | 375 | 330 | 413 | NTAA855-G7 | ≤206 | 6 | 14 | 140*152 |
GNRC450 | 320 | 400 | 360 | 450 | NTAA855-G7A | ≤206 | 6 | 14 | 140*152 |
GNRC500 | 360 | 450 | 400 | 500 | KTA19-G3 | ≤203 | 6 | 18.9 | 159*159 |
GNRC550 | 400 | 500 | 440 | 550 | KTA19-G4 | ≤203 | 6 | 18.9 | 159*159 |
GNRC605 | 440 | 550 | 484 | 605 | KTAA19-G6 | ≤204 | 6 | 18.9 | 159*159 |
GNRC625 | 450 | 563 | 500 | 625 | KTAA19-G7 | ≤204 | 6 | 18.9 | 159*159 |
GNRC700 | 500 | 625 | 560 | 700 | KTA38-G | ≤206 | 12 | 37.8 | 159*159 |
GNRC712 | 520 | 650 | 570 | 712 | QSK19-G3 | ≤206 | 6 | 19 | 159*159 |
GNRC800 | 580 | 720 | 640 | 800 | KTA38-GA | ≤209 | 12 | 37.8 | 159*159 |
GNRC825 | 600 | 750 | 660 | 825 | KTA38-G2 | ≤210 | 12 | 37.8 | 159*159 |
GNRC888 | 640 | 800 | 710 | 888 | KTA38-G2B | ≤210 | 12 | 37.8 | 159*159 |
GNRC975 | 720 | 900 | 780 | 975 | KTA38-G2A | ≤210 | 12 | 37.8 | 159*159 |
GNRC1075 | 800 | 1000 | 860 | 1075 | KTA38-G5 | ≤202 | 12 | 37.8 | 159*159 |
GNRC1375 | 1000 | 1250 | 1100 | 1375 | KTA50-G3 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1375 | 1100 | 1375 | 1310 | 1650 | KTA50-G8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1650 | 1200 | 1500 | 1340 | 1675 | KTA50-GS8 | ≤215 | 16 | 50.3 | 159*159 |
GNRC1675 | 1350 | 1688 | 1500 | 1875 | QSK60-G3 | ≤215 | 16 | 60 | 159*159 |
GNRC1875 | 1500 | 1875 | 1650 | 2063 | QSK60-G3 | ≤215 | 16 | 60 | 159*190 |
GNRC2063 | 1600 | 2000 | 1800 | 2250 | QSK60-G4 | ≤215 | 16 | 60 | 159*190 |
Genset Features:
1. Genuine Commins industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine Cummins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Super Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70DBA
- Q: Does the motor have a good brush or no brush?
- Brush refers to brush, brush dc motor, brush and commutator of the friction and unable to avoid sparks, but relatively speaking, simple control circuit. So, for control, there is a good control of the brush. But for users, a brushless motor clearly has a long life.
- Q: What is the difference between a step motor and an ordinary motor
- Stepper motor and the general difference is mainly lies in the form of the pulse drive (send a pulse control system, can give in a rotary Angle of motor), because of the characteristics of step motor can be combined with modern digital control technology (particularly suitable for mechanical and electrical integration products). However, it is inferior to the traditional closed-loop dc servo motor in the accuracy, speed range and low speed performance of the step motor. It is possible to use stepping motor in an environment where precision is not particularly high, and the step motor can be characterized by simple structure, high reliability and low cost. When used properly, it can even be compared to the performance of dc servo motors.
- Q: The advantage of the pole motor relative to the ordinary motor
- Many choices meet all kinds of user requirements with heat sensitive resistance Adopt optimized design, have high efficiency, can produce considerable energy saving effect The installation of anti-dust sealing ring, tropical, oil-proof sealing ring, oil filling, special shaft extension, special flange etc
- Q: What is the difference between a single phase motor and a two-phase machine?
- Motor has single-phase ac motor and three-phase motor. I haven't heard of a two-phase machine. Are you asking for a positive reverse motor? Three phases are phase modulation. Any two phases are exchanged. C, R, S.
- Q: I have a Siemens 611U ac servo controller, which is replaced by a frequency converter because of the high demand for the power grid. Now the servo motor is useless, I have a Siemens 611U ac servo controller, which is replaced by a frequency converter because of the higher demand for the power grid. Now the servo motor is not used, and the servo electromotor can't be used by ordinary ac asynchronous motor.
- Want to see is synchronous servo or asynchronous servo, general is synchronous servo servo, not using ordinary frequency converter, but Siemens 70 series inverter can control the synchronization and can control the asynchronous, ordinary converter doesn't (work well)
- Q: If the speed of a normal motor is adjusted by the frequency converter, the speed can exceed the rated speed, and if the current power is above the rated speed, what is the change in current power
- General motor frequency control of motor speed can exceed the rated speed, with the increase of the frequency of the motor voltage is reduced, this is the V/F converter control function, so it won't burn motor! But it depends on whether your load is matched by the power of the motor, because no matter how much the motor speed increases the power of the motor is inconvenient! Can change big motor to solve problem! The best frequency of a general frequency converter is 400HZ motor frequency to 100HZ, which is no problem. It will only accelerate the wear and tear of the motor and the equipment without any benefit!
- Q: What is the difference between the brake step motor and the step motor?
- Stepping motor and servo motor with brake and not with two kinds of brakes, belt brake is a brake on stepper motor, motor sports when it relaxed, it lock motor does not move. The aim is to improve the control accuracy and safety factor for some of the more inertial motion.
- Q: Why does the direct start-up of high power motors affect the voltage of the grid
- Because the instantaneous starting current of the three-phase machine is five to seven times the rated electric current, the voltage of the line is reduced, and the voltage of the power grid and the zhou wave are low. Therefore, the high power motor should be initiated by star/Angle to reduce the starting current and avoid the large fluctuation in the voltage of the grid. The star triangulation is initiated by changing the connection of the motor winding, and the pressure is actuated. When activated, the main contactor will give the power to the three ends of the motor winding, which will close the three ends of the motor winding. Winding becomes a star connection, after the completion of the start, time relay action, star contactor disconnect, contactor operation will be three of the power supply to the motor winding end. The winding becomes a delta connection. The motor is fully pressed. During startup, the asterisk contactor and the operating contactor must be interlinked. Image: KT - time relay, KM1 - star contactor, KM2 - the main contactor, KM3 - the operating contactor.
- Q: What is the meaning of the motor from cold and cold?
- Self-cooling is an unsubsidized cooling device that allows the heat to spread through the air or other media. Strong cold is forced cooling, with auxiliary heat sinks, keeping the temperature within a certain range
- Q: What is induction motor? What is the difference between ordinary motors? What is the price of a small induction motor? Is there a inductive dc motor?
- He doesn't say two to: no matter what motor (motor generator... servo. Linear motor) are all electromagnetic induction principle. Called induction motor. Ordinary asynchronous motor of motor is usually used. Is the squirrel cage.
Send your message to us