• AC Alternator Cummins Genset Diesel Electric Generator With KTA19-G3 System 1
  • AC Alternator Cummins Genset Diesel Electric Generator With KTA19-G3 System 2
AC Alternator Cummins Genset Diesel Electric Generator With KTA19-G3

AC Alternator Cummins Genset Diesel Electric Generator With KTA19-G3

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications:

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G1

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190

 

Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9. Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Super Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

Q: What's the difference between an excited motor and an ordinary motor?
Exciter and excitation generator is important equipment of power plants, it is produced by coaxial prime mover rotational dc, for excitation voltage to establish a magnetic field to the rotor of the generator
Q: Which is good for common motor and induction motor?
Induction motor, also called "asynchronous motor, the rotor put in a rotating magnetic field, under the effect of rotating magnetic field, to obtain a rotational torque, thus the rotor rotation. The rotor is a rotating conductor, usually in a squirrel-cage. It was invented by electrical engineer nikola tesla in 1887.
Q: What is the difference between the two class motors and the four-stage motors?
The level 2 motor represents 3, 000 revolutions per minute, and the 4 levels of the motor represent 1, 500 revolutions per minute and you need to know more about the xi 'an motor repair factory. That good point depends on your use and speed requirement!
Q: What is the difference between a single phase motor and a two-phase machine?
You mean should be the difference between the single-phase motor and three-phase motor, the difference between them is to use the power supply is different, single-phase motor using household electricity, three-phase industrial three-phase electric motor.
Q: The difference between pump motor and general motor?
Oil pump motor, also known as explosion-proof motor, is mainly used in coal mines, oil and gas, petrochemical and chemical industry. In addition, in textile, metallurgy, city gas, transportation, grain oil processing, paper, medicine and other departments are also widely used. The oil pump motor is used as the main power equipment, which is commonly used to drive pump, fan, compressor and transmission machine. And ordinary motors are not explosion-proof and can not be used in coal mines, oil and gas, petrochemical and chemical industries.
Q: In the case of ac motor, the voltage will be higher or lower in constant voltage, which will affect the motor.
The frequency can affect the speed of the motor, the frequency is high, the motor speed is fast, the frequency is low, the motor speed is slow. The increase of frequency makes the electric motor feel resistant to increase, the voltage is high, the current decreases if the voltage is constant. The decrease of the frequency of the power supply makes the motor feel less resistant, the voltage is low, and if the voltage is constant, the current increases, and the magnetic saturation is possible.
Q: What is the difference between a servo motor and a direct drive motor?
These two are not a concept Servo motor means that this motor is driven by high frequency pulse driven by servo actuator, which can achieve fixed Angle, fixed speed and fixed torque output. He's talking about the type of motor. A direct drive motor is a direct and rigid connection between the motor and load, without any transmission or coupling in the middle. He's talking about how the motor is used. The servo motor can be connected directly to the load or through the transmission device load. The dc motor can be a servo motor or other motor.
Q: Are motors and motors a concept?
Motor is a general designation, because there are generators, motors, and dc motor, dc generator, etc., so the motor is a general designation, and the motor is not a concept.
Q: How is the rated current of the three-phase machine calculated?
I want to add; The power of a three-phase motor can and should be the power of its rated output, not the power the motor inputs from the grid, which is the only title I. Calculation method is still A P = 1.732 * cos phi x efficiency, the UI is not generally take but should take 1.732, it is 3 square root of arithmetic is, U is the line voltage (380 v), some current (A), cos phi power factor < 1, efficiency (I don't know how to play this symbol)
Q: What is the difference between servo motor and general motors?
The servo motor is called ac servo motor, ac synchronous motor. Common motors are commonly used to communicate asynchronous motors. The main difference is: 1, the distinction between closed-loop feedback and open-loop state principles; , this is also the biggest difference between ac synchronous motor through the backend sensor and encoder feedback speed, position, or torque reference value to form a complete set of drive, and real-time adjustment by the driver drive current value specified by the user to control motor rotation, dc stepper motor and asynchronous usually directly by the frequency converter or direct drive motor rotation, voltage regulator device will not external interference factors such as torque is too big, the heavy load to achieve the dynamic adjustment, so the former is more efficient than the latter, advanced, energy saving, accurate.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords