• Leroy Alternator Deutz Genset Diesel Generator80kva - 1500kva System 1
  • Leroy Alternator Deutz Genset Diesel Generator80kva - 1500kva System 2
Leroy Alternator Deutz Genset Diesel Generator80kva - 1500kva

Leroy Alternator Deutz Genset Diesel Generator80kva - 1500kva

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 Leroy Alternator Deutz Genset Diesel Generator80kva - 1500kva

 

Specifications:

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G1

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190

 

Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9. Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

 

Leroy Alternator Deutz Genset Diesel Generator80kva - 1500kva

Leroy Alternator Deutz Genset Diesel Generator80kva - 1500kva

 

Q: If the value of the capacitor on a motor is smaller, it can also be installed in other motors
The capacitance of this capacitor is so unstable that it can't be used!I hope my answer will help you.
Q: Direct drive motor control mode
So there is no such thing as "the frame type is the control mode of the permanent magnet synchronous motor, the no-frame type is the control mode of dc brushless motor". Perhaps your motor coincided with a particular type of "frame with permanent magnet synchronous motor control mode" or the different type of brushless dc motor control way ". In fact, permanent magnet synchronous motor control method and two kinds of brushless dc motor control method in most cases is one thing, there is not much difference.
Q: What is the solution to other circuit boards when the servo motor is turned on
First, the grounding of the servo drive. Second, if conditions permit, it is recommended to replace the power supply of the servo driver to a shield wire and provide a reliable grounding to the shield.
Q: What is the difference between a three-phase asynchronous motor and a regular motor?
Three-phase asynchronous motor has high efficiency, energy saving, low noise, small vibration, and the advantages of reliable performance, can make using of the drive for different mechanical: such as fan, compressor, water pump, crusher, cutting machine and other equipment, and is available for coal mining, mechanical industry, power plants and various industrial and mining enterprises as a prime mover. Thank you for your reference. I hope I can help you.
Q: Why is electric motors not rotating? Everything else is good.
The causes of motor does not turn more Not only can be a good motor hall do you want to check the controller of the motor wiring sequence
Q: There is a difference between the electric motor and the other motors
So if the sine wave motor, as the name suggests, changes the square wave to a sine wave.I hope my answer will help you.
Q: How does the heat of dc motor control
First of all, you want to let us know whether you have a brush or a brush before you can determine if your fever is likely to be caused by what
Q: Does the motor swing around?
The rotation must be oscillating, and the motor will also produce the left and right swings of the left and right sides
Q: What's the difference between a step motor and a brushless motor?
The step motor can control the Angle of rotation precisely, but no brushless motor is not allowed The motor rotor is a grass-fed structure, neither winding nor permanent magnet. On the rotor of the brushless motor is the rotary rectifier and the excitation winding Brushless motor is used to generate power and power. Step motors are used for precise positioning, such as tool displacement control on machine tools
Q: What is the difference between an energy-saving motor and a general motor
Ordinary motors are ubiquitous in daily life, but energy efficient generators are also beginning to emerge when energy is highly developed. And more and more people are choosing to save electric motors, so what is the difference between an energy-efficient motor and a regular motor? First, the output power of the ordinary motor is less than that of the energy-saving machine. The output power of the ordinary motor is only 50% of the input power, and the energy-saving motor can reach more than 90%. The next year, power issues. The electric motor will be powered by the power supply, and the energy saving motor will turn on the power and the feet will not use electricity. In a society where energy is scarce, we should conserve energy and save money for ourselves. Energy efficient motors can do that. The performance characteristics of high efficiency and energy-saving motors are introduced as follows: 1. Completely based on domestic raw materials. The method of low uncertainty test is used to calibrate the efficiency of the measured results. Contrast with the normal Y series: losses of 15% to 25% and efficiency up 2.5% to 4%. 4. With the improved ventilation systems using highly efficient energy-saving fan of energy-saving motor air gap, the flux density distribution of reasonable design, make the motor efficiency index reaches more than GB18613-2006 grade 2 energy efficiency standard.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches