• Open Type Perkins Diesel Generating Set  for Building Use System 1
  • Open Type Perkins Diesel Generating Set  for Building Use System 2
Open Type Perkins Diesel Generating Set  for Building Use

Open Type Perkins Diesel Generating Set for Building Use

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
500 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Open Type Perkins Diesel Generating Set  for Building Use

Founded in 1932 in the United Kingdom, Perkins annual output nearly 400,000 engines.The diesel and natural gas engines are widely used in various industries due to their advantages of economy, reliability and durability.As the world class A certified company, Perkins diesel generator sets have genuine trend internationalization. Today, Perkins has established production departments in 13 countries and formed a global service network consisting of more than 1,000 distribution points and service centers. In the field of power generation, the 7kw-1811kw diesel generator sets have excellent performance, reliability, durability and other advantages.


OPEN TYPE PERKINS DIESEL GENERATING SET DATA SHEET

Genset Model

Standby Power

Prime Power

Fuel Consumption

Overall Size

Weight

Fuel Tank Capacity

Engine Description

Alternator Model

KVA

KW

KVA

KW

100%    L/H

L x W x H (mm)

KG

L

 Model

Oil Capacity(L)

Coolant Capacity(L)

Stamford

ZOP10PK

10

8

9

7

2.6

1500x650x1225

425

160

403A-11G1

4.9

5.2

LSA40VS1

ZOP10PK

10

8

9

7

2.6

1500x650x1225

425

160

403D-11G

4.9

5.2

LSA40VS1

ZOP14PK

14

11

13

10

3.67

1500x650x1225

496

160

403D-15G

6

6

LSA40VS2

ZOP14PK

14

11

13

10

3.48

1500x650x1225

496

160

403A-15G1

6

6

LSA40VS2

ZOP16PK

16

13

15

12

3.48

1500x650x1225

496

160

403A-15G2

6

6

LSA40S3

ZOP22PK

22

18

20

16

5.3

1500x650x1225

610

160

404D-22G

10.6

7

LSA40M5

ZOP22PK

22

18

20

16

5.3

1500x650x1225

610

160

404A-22G1

10.6

7

LSA40M5

ZOP30PK

30

24

27

22

6.7

1500x650x1225

660

160

404D-22TG

10.6

9.3

LSA42.3VS2

ZOP33PK

33

26

30

24

6.98

1650x750x1280

780

221

1103A-33

7.9

10.2

LSA42.3VS3

ZOP50PK

50

40

45

36

10.6

1650x750x1280

887

221

1103A-33T/DK83398S

7.9

10.2

LSA42.3M7

ZOP65PK

65

52

60

48

13.8

1650x750x1280

908

221

1104C-44TG2

8

13

LSA42.3L9

ZOP65PK

65

52

60

48

13.8

1650x750x1280

908

221

1103A-33T/DK83399S

7.9

10.2

LSA42.3L9

ZOP75PK

73

58

65

52

14.8

1750x850x1300

923

221

1104A-44TG1

8

13

LSA44.3S2

ZOP88PK

88

70

80

64

18.4

1750x850x1300

1037

221

1104A-44TG2

8

13

LSA44.3S3

ZOP88PK

88

70

80

64

18.4

1750x850x1300

1037

221

1104C-44TAG1

8

12.6

LSA44.3S3

ZOP100PK

100

80

90

72

20.5

2240x850x1320

1175

300

1104C-44TAG2

8

12.6

LSA44.3S4

ZOP110PK

110

88

100

80

24

2240x850x1320

1190

300

1104C-44TAG2

8

12.6

LSA44.3S5

ZOP150PK

150

120

135

108

29.9

2900x900x1536

1760

685

1106A-70TG1

16.5

21

LSA44.3M8

ZOP158PK

158

126

142

115

39.7

2900x900x1536

1760

685

1106D-E70TAG2

16.5

21

LSA44.3L10

ZOP165PK

165

132

150

120

33.4

2900x900x1536

1760

685

1106A-70TAG2

16.5

21

LSA44.3L10

ZOP175PK

175

140

160

128

42.3

2900x900x1536

1760

685

1106D-E70TAG3

16.5

21

LSA44.3L12

ZOP200PK

200

160

180

144

41.6

2900x900x1536

1796

685

1106A-70TAG3

16.5

21

LSA46.3S2

ZOP200PK

200

160

180

144

49.3

2900x900x1536

1830

685

1106A-E70TAG4

16.5

21

LSA46.3S2

ZOP220PK

220

176

200

160

45.8

2900x900x1536

1830

685

1106A-70TAG4

16.5

21

LSA46.3S3

ZOP220PK

220

176

200

160

44.6

3000x1200x2000

2760

1100

1506A-E88TAG1

41

29.6

LSA46.3S3

ZOP250PK

250

200

225

180

48.6

3000x1200x2000

2760

1100

1506A-E88TAG2

41

29.6

LSA46.3S4

ZOP275PK

275

220

250

200

50

3000x1200x2000

2760

1100

1506A-E88TAG3

41

29.6

LSA46.3S5

ZOP300PK

300

240

275

220

60.2

3000x1200x2000

2860

1100

1506A-E88TAG4

41

33.2

LSA46.3M7

ZOP330PK

330

264

300

240

64.9

3000x1200x2000

2860

1100

1506A-E88TAG5

41

33.2

LSA46.3M8

ZOP400PK

400

320

350

280

70

3200x1206x1980

2932

1200

2206A-E13TAG2

40

51.4

LSA46.3L11

ZOP400PK

400

320

350

280

70

3200x1206x1980

2932

1200

2206C-E13TAG2

40

51.4

LSA46.3L11

ZOP450PK

450

360

400

320

82.7

3200x1206x1980

3069

1200

2206A-E13TAG3

40

51.4

LSA47.2S4

ZOP450PK

450

360

400

320

82.7

3200x1206x1980

3069

1200

2206C-E13TAG3

40

51.4

LSA47.2S4

ZOP500PK

500

400

450

360

95.6

3500x1540x1850

3400

1200

2506A-E15TAG1

62

58

LSA47.2S5

ZOP500PK

500

400

450

360

95.6

3500x1540x1850

3400

1200

2506C-E15TAG1

62

58

LSA47.2S5

ZOP550PK

550

440

500

400

106

3500x1540x1850

3551

1200

2506A-E15TAG2

62

58

LSA47.2M7

ZOP550PK

550

440

500

400

106

3500x1540x1850

3551

1200

2506C-E15TAG2

62

58

LSA47.2M7

ZOP650PK

650

520

600

480

126.6

3500x1540x2050

3813

1450

2806C-E18TAG1A

87

61

LSA47.2L9

ZOP660PK

660

528

600

480

126.6

3500x1540x2050

3813

1450

2806A-E18TAG1A

87

61

LSA47.2L9

ZOP700PK

700

560

650

520

129.3

3500x1540x2050

3925

1450

2806A-E18TAG2

87

61

LSA49.3S4

ZOP825PK

825

660

750

600

152.3

4350x1750x2270

5525

1800

4006-23TAG2A

113.4

140

LSA49.3M8

ZOP880PK

880

704

800

640

171.8

4350x1750x2270

5570

1800

4006-23TAG3A

113.4

140

LSA49.3M8

ZOP1000PK

1000

800

900

720

188

4700x2070x2414

6667

1400

4008TAG1A

153

234

LSA49.3L9

ZOP1100PK

1100

880

1000

800

215.2

4700x2070x2414

6792

1400

4008TAG2

153

234

LSA49.3L10

ZOP1100PK

1100

880

1000

800

215.2

4700x2070x2414

6792

1400

4008TAG2A

153

234

LSA49.3L10

ZOP1250PK

1250

1000

1125

900

237.2

4700x2070x2414

6850

1400

4008-30TAG3

153

234

LSA50.2M6

ZOP1375PK

1375

1100

1250

1000

258.1

4800x2200x2477

9950

3000

4012-46TWG2A

177

187

LSA50.2M6

ZOP1500PK

1500

1200

1375

1100

279.1

4900x2200x2477

10205

3000

4012-46TWG1A

177

274

LSA50.2L7

ZOP1500PK

1500

1200

1375

1100

279.1

4900x2200x2477

10205

3000

4012-46TWG3A

177

187

LSA50.2L7

ZOP1600PK

1600

1280

1500

1200

299

4900x2200x2477

10435

3000

4012-46TWG4A

177

187

LSA50.2L8

ZOP1650PK

1650

1320

1500

1200

299

4900x2200x2477

10435

3000

4012-46TAG2A

177

274

LSA50.2L8

ZOP1875PK

1875

1500

1688

1350

367.3

5100x2200x2477

11200

3000

4012-46TAG3A

177

274

LSA52.3S5

ZOP2000PK

2000

1600

1850

1480

381.3

6100x2740x3120

13780

3000

4016TAG1A

237

368

LSA52.3S5

ZOP2000PK

2000

1600

1850

1480

381.3

6100x2740x3120

13780

3000

4016-61TRG1

237

376

LSA52.3S5

ZOP2250PK

2250

1800

2000

1600

434

6100x2740x3120

13875

3000

4016TAG2A

237

368

LSA52.3S6

ZOP2250PK

2250

1800

2000

1600

422

6100x2740x3120

13875

3000

4016-61TRG2

237

376

LSA52.3S6

ZOP2500PK

2500

2000

2250

1800

467.6

6100x2740x3120

14900

3000

4016-61TRG3

237

376

LSA52.3L9

 


Q: If electric vehicles included a generator they could charge the battery while moving. It seems the best choice to me.
Because a generator runs on gas. And they do have regenerating chargers while the car is moving. They just are not a typical generator
Q: Hi GuysOkay i have been given the task of fitting a 240v generator to an RV in to one of it's closet spaces.It needs to power one 240v socket, charge the RV battery (standard battery on trickle charge) and power the shower which doesn't have a boiler as such it heats the water on a 'as and when' basis. Low wattage lighting also two 40W lightsThere is plenty of space. so I thought how about try and fit a generator than runs on renewable energy.I just need to know what direction I should be looking in. HydrogenSolar (Doubt it)Bio-FuelAnything else?Also, is it best to convert an existing design of generator, buy a new one or build one from scratch to fit?Any help would be truly awesomePeace
You need the power level, and I suspect it is very high. The shower is the problem, as it will use several thousands of watts only for a few minutes, then zero power for the rest of the time. Everything else is a hundred watts or so. If you could switch to a tank hot water storage system, where you can heat the water slowly, with perhaps 500 watts over hours of time, so it is ready for those showers. Perhaps even less. Hydrogen is not practical, as it is not readily available, neither is bio-fuel. Your best bet is solar, as you have plenty of space on the roof for the panels. You will need a charge controller, a few sealed deep-discharge 12 volt batteries, and an inverter. The batteries can store up power for the times you need it. The number of batteries will be determined the needed power levels. Again, the shower predominates. Get readings of watts used and time lengths, so you can calculate the number of batteries. .
Q: Elec. bill is too high, so I wanna run 2HP swimming pool pump via generator. It's 240V. How big a generator do I need? Is diesel less to purchase than gas? Is diesel cheaper to run? Can I run the pool say 6 hrs a day on generator designed for emergency back-up?
you can run the pool off a generator, but you will nedd a a heavy duty one, the generator is going to have to power the pump, in order to pump the water i say you need a a 420 v generator. lowes home improvment store has them.
Q: i have 350kw old diesel generator and want to calculate the exact consumtionption at various loads.
You will need the specific fuel consumption of the engine, but it is probably close to 0.5 pounds per HP hour or 250g/KW.h. That is specified for the output shaft power at the operating RPM. It depends whether you have a turbo charger, the fuel a little, the air temperature and barometric pressure. Make sure exhaust and air intakes are not restricted too. You may find for a gen-set that you get a set of curves with the fuel consumption for different KW output. These account for the alternator efficiency already. Contact the engine supplier etc for this info. Use KWh from the generator (volts x amps x time gives KVAh not KWh). The amps might be up to 20% higher, depending on power factor of the load. The reactive part of the load does not need power from the engine. This is why I say to use KWh not KW, as you can use ordinary KWh meters (which ignore the reactive load). Allow for the efficiency of the generator (which varies somewhat, especially at light loads). Let's say 85%. Remember it is exciting the field, so that must be included in the efficiency. Thus if you are using 350KW for one hour, the engine provides 350KWh/0.85 411.8KWh (412KWh). The fuel used is 412KWh x 0.25Kg 103Kg of fuel. Now you need the specific gravity of the fuel you are using. You can call the fuel distributor. Ideally this is corrected for temperature of the fuel with the engine running, remembering the engine heats the fuel in the day tank due to recirculation. Let's assume 0.85 is the SG, so that means 0.85kg/l so 103Kg of fuel is 103/0.85 121 liters. In practice it may be higher, especially if the engine is old and worn. This answer is something like the maximum consumption, full rated output, 121 liters per hour. OR 26.6 imperial gallons or 32 US gallons per hour.
Q: I have a 33 feet sailboat. I will like to power it with a wind generator for all our needs, including a little fridge and an ac its possible? How powerful should it be? Where can I learn more about it?
your okorder
Q: Going to buy another vital generator have 2 deals on the table . gas generac 8000 running watt $1350. new or 5000 watt kipon desiel used about 4 years $800. needs new battery. what would you pick and why? thanks
Diesel Issues: Regular oil changes - about 2:1 to a gas-fired generator. Diesel fuel is may gel in very cold weather - you may have to use a kerosene mix. Diesel fuel has a shelf-life such that you will have to add fuel stabilizers and run out the fuel at least three times per year (more in a humid climate) to prevent breakdown. You will have to change the fuel filter at least once per year. If you run out of diesel and cannot get to it - you are out of luck. Which leads to liquid fuel storage issues, shelf-life and so forth. Diesel fuel is a bit over twice the cost of natural gas as a fuel in this situation. Go with the natural gas unit. It is new, has a warranty and you _know_ that it will have no hidden flaws. Now, if by Gas you mean gasoline - go with the diesel unless you are in a very cold climate. Hands down.
Q: Hi.My diesel electric generator has a sticker that says Change oil every 100hrs. Use 10w-30 grade CC. But I can't find this oil anywhere. The closest I have found are 10w-30 Mobil1 synthetic oil (API SM/CF) and 15w-40 Pennzoil gold (with diesel protection, API CJ, CI, CF etc. /SM). Which one should I use?Thanks!
I beleive that CC is obsolete. Search diesel engine oil and find the one that matches your engine type.
Q: Hi and thanks for reading.I have a small trailer I am looking for a back up propane generator for.We have wind storms here that knock out power for days on end, about a half dozen times per year, so I'm looking to get some back up electricity, howeverMy lot size is SMALL, so is my trailer. I have a natural gas line, and gas furnace, so I only use about 1500 watts at peak times, so I figure a 3k watt generator will more than cover my needs.SOUND is a huge factor. I have the worst neighbors in the world and I really need something quiet. I'm looking for something with less than 60 ddb.I have seen a lot of propane generators that look good, but I dont know if they can be used with natural gas easily. I think so, but would love to hear if thats true, and they dont have the standby plug feature, which I need to save my fish tank, any know if this can be easily changed by a skilled electrician?Thank you. Any and all help would be greatly appreciated.
You can buy natural gas generators both new and used at swift equipments at various powers and fuel options
Q: about diesel generator
a rad, water pump , water hoses
Q: I have bought an ex hire Pike trafic signal trailer which contains a diesel generator. it looks very similar to this (
It's difficult to guess at exact ratings based solely on a picture. Check the generator housing for its specification plate. You can sometimes ballpark a rating based on the engine size. For each horsepower the system should be capable of producing approximately 500 watts. A 8HP engine is usually connected to a 4000 watt generator, 10HP for 5000W, 14HP for 7000W, etc. Many generators have two coils to supply AC output. For 120VAC output only the two coils are placed in parallel. For 120/240VAC the coils are wired in series and mid connection becomes the neutral. If the generator is presently capable of supplying 1kW, changing the output to supply 240VAC will still supply a maximum of 1kW. The maximum each output coil will supply at 120VAC is 500W. You need to separate the two output coils and wire them in series. Install a proper 240VAC outlet on the generator. The circuit breaker should be reduced to half of its present current rating. Read through my home generator page for other ideas.

Send your message to us