OPEN TYPE IMPORT CUMMINS DIESEL GENERATING SET DATA SHEET

Genset Model

Standby Power

Prime Power

Fuel Consumption

Overall Size

Weight

Fuel Tank Capacity

Engine Description

Alternator Model

KVA

KW

KVA

KW

100%    L/H

L x W x H (mm)

KG

L

 Model

Oil Capacity(L)

Coolant Capacity(L)

Stamford

ZOP11JK

11

8.8

10

8

2.1

1667x930x1247

550

160

X1.3-G2

4.5

15

PI044E

ZOP28JK

28

22

25

20

5.3

1667x930x1247

582

267

X2.5-G2

7

20

PI144E

ZOP38JK

38

30

35

28

7.4

1753x930x1250

875

267

X3.3-G1

6.8

20

PI144H

ZOP44JK

44

35

40

32

8.5

2115x1044x1516

1105

267

S3.8-G1

11

20

PI144J

ZOP55JK

55

44

50

40

10.6

2115x1044x1516

1120

267

S3.8-G4

11

20

UCI224D

ZOP66JK

66

53

60

48

12.7

2115x1044x1516

1105

267

S3.8-G7

11

20

UCI224E

ZOP90JK

90

72

82

66

17.5

2200x830x1250

1150

374

QSB5-G3

12.2

25

UCI224G

ZOP100JK

100

80

91

73

19.3

2200x955x1490

1272

374

QSB5-G4

12.2

25

UCI274C

ZOP110JK

110

88

100

80

21.2

2200x955x1490

1272

374

QSB5-G5

12.2

25

UCI274C

ZOP150JK

150

120

136

109

28.9

2200x955x1490

1290

374

QSB5-G6

12.2

29

UCI274E

ZOP175JK

175

140

150

120

31.8

2656x1100x1658

1550

374

QSB7-G3

18.9

33

UCI274F

ZOP200JK

200

160

180

144

38.2

2656x1100x1658

1560

374

QSB7-G4

18.9

33

UCI274G

ZOP220JK

220

176

200

160

42.4

2656x1100x1658

1572

374

QSB7-G5

18.9

33

UCI274H

ZOP250JK

250

200

225

180

47.7

3135x1100x1928

2300

374

QSL9-G2

26.5

35

UCDI274J

ZOP275JK

275

220

250

200

53

3135x1100x1928

2347

374

QSL9-G3

26.5

35

UCDI274K

ZOP330JK

330

264

300

240

63.6

2870x1120x1743

3150

374

QSL9-G5

26.5

35

HCI444D

ZOP500JK

500

400

450

360

96.5

3427x1500x2066

4121

1200

QSX15-G6

91

42

HCI544C

ZOP550JK

550

440

500

400

106.6

3340x1425x1772

5050

1200

QSX15-G8

91

42

HCI544C

ZOP550JK

550

440

500

400

107.3

3350x1280x1934

3940

1200

KTA19-G4

50

67

HCI544C

ZOP700JK

700

560

625

500

132.5

4047x1608x1942

5760

1700

VTA28-G5

83

80

HCI544F

ZOP810JK

810

650

750

600

159

4266x1879x2052

6420

1800

QSK23-G2

103

57

LVI634B

ZOP825JK

825

660

750

600

159

4047x1608x2187

6040

1800

VTA28-G6

83

80

LVI634B

ZOP880JK

880

704

800

640

171.7

4266x1879x2052

6680

1800

QSK23-G3

103

57

HCI634G

ZOP1000JK

1000

800

910

728

192.9

4297x1685x2079

6296

1800

QST30-G3

154

114

HCI634H

ZOP1100JK

1100

880

1000

800

212.3

4571x1785x2229

8350

1800

QST30-G4

154

106

HCI634J

ZOP1100JK

1100

880

1000

800

212

4470x1785x2229

8350

1800

KTA38-G5

199

135

HCI634J

ZOP1250JK

1250

990

1125

900

240.6

4470x1805x2244

8550

1800

QSK38-G2

170

106

HCI634K

ZOP1375JK

1375

1100

1250

1000

270

4470x1805x2244

8600

3000

QSK38-G5

170

106

LVI634G

ZOP1375JK

1375

1100

1250

1000

270.3

5283x2066x2233

10075

3000

KTA50-G3

177

152

LVI634G

ZOP1500JK

1500

1200

1375

1100

296.8

4783x2066x2233

9575

3000

QSK50-G3

235

245

PI734B

ZOP1675JK

1675

1340

1400

1120

297.2

5690x2033x2330

10324

3000

KTA50-G8

204

245

PI734C

ZOP1650JK

1650

1320

1500

1200

318

5690x2033x2330

10324

3000

KTA50-GS8

204

245

PI734C

ZOP1700JK

1700

1360

1540

1232

326.5

4783x2066x2233

9775

3000

QSK50-G4

235

245

PI734C

ZOP1825JK

1825

1460

1650

1320

349.8

4783x2066x2233

9775

3000

QSK50-G7

235

245

PI734D

ZOP2000JK

2000

1600

1875

1500

397.5

5900x2180x2600

14257

3000

QSK60-G3

280

242

PI734E

ZOP2250JK

2250

1800

2000

1600

433.5

6175x2286x2537

15510

3000

QSK60-G4

280

242

PI734F

ZOP2500JK

2500

2000

2000

1600

434

6225x2286x2537

15590

3000

QSK60-G13

280

242

PI734H

ZOP2500JK

2500

2000

2250

1800

6000x2660x2900

16500

3000

QSK60-G21

280

242

PI734H

ZOP2750JK

2750

2200

2500

2000

7200x2900x3830

2000

3000

QSK78-G18

466

295

LVSI804S

ZOP3000JK

3000

2400

2750

2200

7200x2900x3830

2000

3000

QSK78-G9

466

295

LVSI804S

 


Q: Hi. I'm thinking about getting a Kubota Diesel Generator. I have read in many places that the Kubota Diesel engine is the gold standard of Diesel engines. So I'm not worried about that. What i need to know is this, is the generator as a whole dependable? Will over loading it for a few short seconds when the AC compressor kicks in burn it out or shorten its life?Any other insight would be appreciated.Thanks for your answers
Kubota diesel plants are being used more and more in industry, replacing some of the old standbys like Kohler, Perkins and even Caterpillar in lighter applications. I don't think you will regret buying a Kubota.
Q: From what I understand, when the earthquake struck, the nuclear reactors had shut down (control rods were inserted). As a result, the power coming from the steam turbine generators were shut off.At the same time, the earthquake had knocked out Japan's power grid, so power coming from outside the power plant was out.Then the emergency diesel generators went into effect, but was knocked out an hour later as well, and people suspect it was from the tsunami.Would the disaster still have happened if they kept the steam turbine generators running (which means never shutting down the reactor via control rods), and water pumping, instead of shutting it down and letting the backup power direct the emergency cooling?
if hte control rods had not be inserted it would of catastrophic. the reactors would be working at 100% and no one can shut it down becasue there is no power. left for too long and unable to stop the reaction, it could lead to an actual meltdown like at the Chernobyl. there's a good reason why during any emergency the control rods are inserted. its standard protocol since the very first nuclear reactor experiments back in the late 1930s under some gym in the eastern USA. you want to shut down the most dangerous thing first, the one that has the most potential for catastrophe before doing anything else.
Q: I am build a 40KVA permanent magnet generator for diesel engine. the customer request the voltage is DC 28V after an rectifier. may be this 28V dc charge for the battery. can someone help me how much AC voltage should be output by the permanent magnet generator?permanent magnet generator----AC ???V----rectifier---28VDC---charge to battery.
In AC side connect a series high current Choke with less no of turns take the out put use a High current bridge Diodes with suitable heat sink.For regulating out put ,In the series choke place a Dc winding that can be excited by a separate dc circuit, Increase saturation will give same voltage decrease excitation will give drop in voltage.It is like magnetic Amplifier.Set the out put voltage with pre set point or a regulating circuit.I have given rough Idea If you want further detail PM me (This only cheapest method unless you have use thyristor or others to con troll may be expensive)
Q: Are they cranked by a self starter? Is there such an immensely powerful self starter that runs off batteries and can start such a big engine?Or are they started by some gasoline powered motor?
A diesel engine is started (like an automobile) by turning over the crankshaft until the cylinders fire or begin combustion. The starting can be done electrically or pneumatically. Pneumatic starting was used for some engines. Compressed air was pumped into the cylinders of the engine until it gained sufficient speed to allow ignition, then fuel was applied to fire the engine. The compressed air was supplied by a smallauxiliary engine or by high pressure air cylinders carried by the locomotive. Electric starting is now standard. It works the same way as for an automobile, with batteries providing the power to turn a starter motor which turns over the main engine. In older locomotives fitted with DC generators instead of AC alternators, the generator was used as a starter motor by applying battery power to it.
Q: I am currently a diesel mechanic in the Army. I know a lot about bothe gas and Diesel engines in cars trucks and generators. My contract is almost up and I m trying to transition back into the civilian world. I was just wondering if someone could help me out with any major differences between a 6.7 liter Diesel engine and the Diesel engines in heavy diesel trucks
w
Q: I have noticed that our kilowatthour meter reads backwards when I use some electrical appliances, please explain why. plgperera.
are you sure u dont have a diesel generator that sells el. energy back to the grid? jk Is this first time you look at the meter? If so take a look again, should be ok.
Q: i have Diesel generator100KVA , how many air conditioner of 2 tons (i phase)i can use with this generator without overload
you need to look at the power requirements of the air conditioner of 2 tons it should indicate it's power requirements.
Q: There are several ways to start the diesel generator set?
when the control switch to the stop (STOP), or remain in the automatic, but electricity has been restored when ATS sent to the stop signal, diesel generator will automatically stop
Q: I have a (2306A-E14TAG3) PERKINS diesel engine electric generator, every two hours it turns off by itself. The generator room is well ventilated, opened from all sides, while the exhaust is free for atmosphere without any extensions from the muffler.- 66% used as part load.- Note that this generator is a new generator. ambient temperature is almost 30 degrees celcius, humidity65%.Please help me with this issue, because every two hourse i used to cool the radiator from outside by water! I appreciate your help
REASONS FOR PERKINS GENERATORS TO SHUT DOWN (according to Ehow): 1. Not putting out correct voltage (too high or too low). 2. Wrong frequency 3. Wrong speed 4. Wrong oil pressure (too high or too low). ///////// Other sources of failure: High current, battery won't charge, speed sensor not working,
Q: I know they are more expensive.
Yes. But they also burn much hotter in the SOFC.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches