OPEN TYPE IMPORT CUMMINS DIESEL GENERATING SET DATA SHEET

Genset Model

Standby Power

Prime Power

Fuel Consumption

Overall Size

Weight

Fuel Tank Capacity

Engine Description

Alternator Model

KVA

KW

KVA

KW

100%    L/H

L x W x H (mm)

KG

L

 Model

Oil Capacity(L)

Coolant Capacity(L)

Stamford

ZOP11JK

11

8.8

10

8

2.1

1667x930x1247

550

160

X1.3-G2

4.5

15

PI044E

ZOP28JK

28

22

25

20

5.3

1667x930x1247

582

267

X2.5-G2

7

20

PI144E

ZOP38JK

38

30

35

28

7.4

1753x930x1250

875

267

X3.3-G1

6.8

20

PI144H

ZOP44JK

44

35

40

32

8.5

2115x1044x1516

1105

267

S3.8-G1

11

20

PI144J

ZOP55JK

55

44

50

40

10.6

2115x1044x1516

1120

267

S3.8-G4

11

20

UCI224D

ZOP66JK

66

53

60

48

12.7

2115x1044x1516

1105

267

S3.8-G7

11

20

UCI224E

ZOP90JK

90

72

82

66

17.5

2200x830x1250

1150

374

QSB5-G3

12.2

25

UCI224G

ZOP100JK

100

80

91

73

19.3

2200x955x1490

1272

374

QSB5-G4

12.2

25

UCI274C

ZOP110JK

110

88

100

80

21.2

2200x955x1490

1272

374

QSB5-G5

12.2

25

UCI274C

ZOP150JK

150

120

136

109

28.9

2200x955x1490

1290

374

QSB5-G6

12.2

29

UCI274E

ZOP175JK

175

140

150

120

31.8

2656x1100x1658

1550

374

QSB7-G3

18.9

33

UCI274F

ZOP200JK

200

160

180

144

38.2

2656x1100x1658

1560

374

QSB7-G4

18.9

33

UCI274G

ZOP220JK

220

176

200

160

42.4

2656x1100x1658

1572

374

QSB7-G5

18.9

33

UCI274H

ZOP250JK

250

200

225

180

47.7

3135x1100x1928

2300

374

QSL9-G2

26.5

35

UCDI274J

ZOP275JK

275

220

250

200

53

3135x1100x1928

2347

374

QSL9-G3

26.5

35

UCDI274K

ZOP330JK

330

264

300

240

63.6

2870x1120x1743

3150

374

QSL9-G5

26.5

35

HCI444D

ZOP500JK

500

400

450

360

96.5

3427x1500x2066

4121

1200

QSX15-G6

91

42

HCI544C

ZOP550JK

550

440

500

400

106.6

3340x1425x1772

5050

1200

QSX15-G8

91

42

HCI544C

ZOP550JK

550

440

500

400

107.3

3350x1280x1934

3940

1200

KTA19-G4

50

67

HCI544C

ZOP700JK

700

560

625

500

132.5

4047x1608x1942

5760

1700

VTA28-G5

83

80

HCI544F

ZOP810JK

810

650

750

600

159

4266x1879x2052

6420

1800

QSK23-G2

103

57

LVI634B

ZOP825JK

825

660

750

600

159

4047x1608x2187

6040

1800

VTA28-G6

83

80

LVI634B

ZOP880JK

880

704

800

640

171.7

4266x1879x2052

6680

1800

QSK23-G3

103

57

HCI634G

ZOP1000JK

1000

800

910

728

192.9

4297x1685x2079

6296

1800

QST30-G3

154

114

HCI634H

ZOP1100JK

1100

880

1000

800

212.3

4571x1785x2229

8350

1800

QST30-G4

154

106

HCI634J

ZOP1100JK

1100

880

1000

800

212

4470x1785x2229

8350

1800

KTA38-G5

199

135

HCI634J

ZOP1250JK

1250

990

1125

900

240.6

4470x1805x2244

8550

1800

QSK38-G2

170

106

HCI634K

ZOP1375JK

1375

1100

1250

1000

270

4470x1805x2244

8600

3000

QSK38-G5

170

106

LVI634G

ZOP1375JK

1375

1100

1250

1000

270.3

5283x2066x2233

10075

3000

KTA50-G3

177

152

LVI634G

ZOP1500JK

1500

1200

1375

1100

296.8

4783x2066x2233

9575

3000

QSK50-G3

235

245

PI734B

ZOP1675JK

1675

1340

1400

1120

297.2

5690x2033x2330

10324

3000

KTA50-G8

204

245

PI734C

ZOP1650JK

1650

1320

1500

1200

318

5690x2033x2330

10324

3000

KTA50-GS8

204

245

PI734C

ZOP1700JK

1700

1360

1540

1232

326.5

4783x2066x2233

9775

3000

QSK50-G4

235

245

PI734C

ZOP1825JK

1825

1460

1650

1320

349.8

4783x2066x2233

9775

3000

QSK50-G7

235

245

PI734D

ZOP2000JK

2000

1600

1875

1500

397.5

5900x2180x2600

14257

3000

QSK60-G3

280

242

PI734E

ZOP2250JK

2250

1800

2000

1600

433.5

6175x2286x2537

15510

3000

QSK60-G4

280

242

PI734F

ZOP2500JK

2500

2000

2000

1600

434

6225x2286x2537

15590

3000

QSK60-G13

280

242

PI734H

ZOP2500JK

2500

2000

2250

1800

6000x2660x2900

16500

3000

QSK60-G21

280

242

PI734H

ZOP2750JK

2750

2200

2500

2000

7200x2900x3830

2000

3000

QSK78-G18

466

295

LVSI804S

ZOP3000JK

3000

2400

2750

2200

7200x2900x3830

2000

3000

QSK78-G9

466

295

LVSI804S

 


Q:Hi. We're off grid and therefore installing a 3 phase Diesel generator. Each phase is rated at 20 Amps continuous(23 Amps max). we want to run 3 Split type ACs, one on each phase, plus some other small appliances.Our problem is that each AC has a start up current of 20 Amps, which will trip the safety circuit on the generator everytime it comes on.The ACs running current is only 8 Amps, but jumps to 20 Amps for a split second everytime the Compressor comes on.Is there a simple way to control the start up current on the ACs? I read something about putting a coil of wire on the input of the Compressor. I tried that with a water pump just to check if it works. The surge current was still there.Any ideas if I can use a Capacitor? If yes, can you tell me what capacity I should use? If you give me the formula I can figure it myself. We run on 220-240 Volts, 50 HZ.Thanks for your answers.
Is it too late to switch to a 240 volt single phase generator of the same capacity? This would have a 60 amp capability and would handle the surges with no trouble. I don't see how a capacitor will help. If you are stuck with the 3 phase generator, perhaps you can switch the ACs for ones with 3 phase motors. That will spread the surge over the 3 phases. There are also soft-start ACs .
Q:i have 45 kva Perkins diesel generator cranks, battery is ok,does anybody know why the engine doesn't start?every think looks clear!!!please help!!!
Good, a general diesel engine similar to a Lister-Petter naturally aspirated will produce about 20 HP for an hour from one gallon of diesel. You will have acquired a few 45 gallon tank and about 28 horsepower. I`m no longer going to get my calculator out presently of night however i might advise that it might well run for 33 hours at full chat, but when the weight on it is small then greatly longer because it runs at consistent revs regardless of load, except the load is immoderate. As another be aware; A two stroke petrol is considered to produce 10 HP per hour per gallon. A 4 stroke petrol is regarded to supply 15 HP per hour per gallon. A gallon is 4.Fifty four litres. Engines with turbos equipped are an utterly exclusive story, as are latest lean burn engines. Hope that helped, high-quality of luck, Bob.
Q:For hydropower how much MWh can be generated with same capacity plant?. (Because plant never run for 24 hours of the day we need a factor to calculate above value)
just multiply 100 MW by the number of hours in a year to get MW-hr per year 100 MW x 24h/day x 365.25 day/yr 876600 MW-hr / year If it's not running 24 hours a day, just substitute the correct number. .
Q:What are the advantages of diesel generator sets
Advantages: 1 small noise; 2 low temperature conditions, easy to start quickly.
Q:I want to buy a GENMAX HY6500 GENERATOR FOR 220/240 VOLTS but is wondering if this generator is good. I saw one sold at $1,239 and on another site it was $299.00. I was adviced not to buy Wolf power because of poor customer ratings. I haven't seen any customer rating for GENMAX. I guess this is a Chinese company.The problem I am having in US is that I canot get a 50hz 220-240 volt generators. All I get is 60hz and I am told thy wouldn't work for Africa. Can anybody help?
There is very little equipment made for one frequency that won't work just fine on the other frequency, (50 vs 60 Hz). The only problem you would run into is where a synchronous motor needs to run at an exact speed, such as tape recorders. But almost everything made today will function just fine on either 50 or 60 Hz. Actually, a 60 Hz generator can be made to put out 50 Hz by re-adjusting the governor to run the motor a little slower. For instance, if it is a 2-pole generator operating at 3600 RPM, the motor could be adjusted to run at 3000 RPM. If the generator was 4 poles, designed to run at 1800 RPM, readjusting the governor to run at 1500 RPM would do the trick. The only problem you might encounter would be slightly lower voltage - 100/200 Volts - but the the automatic voltage regulator should handle that just fine by increasing the field voltage/current.
Q:I have diesel generator and when I loaded it up to 400 KW trip due to low ferquncy in which its total load 905 KW after I check up , I think that because fuel is not increase to feed injuction pump so that I want to know how actuator working ?
By the revolutions of the generator, or the (presuming AC output) frequency of the power generated. If the frequency is low, the revolutions are low. If the revolutions drop off when load is added, or frequency falls, you have a problem. somewhere.
Q:For 100Kw generator, what will be minimum/ maximum loadfor its safe operation.
The maximum load will be given by the exhaust temperature, regardless of the nameplate rating. There is a maximum steady state temperature, which can be exceeded for short periods, say, 10 to 20 %, given by the engine mfr. The minimum load for an engine which runs at constant speed, i.e., a power generator, is about 50%. Below that it starts to shake dangerously. . .
Q:I'm a student majoring in Architecture one of my class, Building Utilities, needs me to survey a high rise building. In my team, we divided the parts bc there are so many and one of my job is to electricity. Can someone explain to me the meaning of phase, R.P.M, power factor, and (especially) their respective units/numbers from this picture
Phase is 3Φ 4W, which means three phase, four wires. Three wires for each of the phases and one wire for the neutral. There are two ways to connect 3 phase generators, ywe which looks like the letter Y (3 or 4 wires) or delta which looks like a triangle (3 wires). Voltage is 380/220V, which means a wye-connected generator with two voltages available. For heavy loads like heating and motors, a line voltage of 380V, measured across two of the phases, is available. For light loads like lights and outlets, a phase voltage of 220V, measured across a phase to neutral, is available. The use of 380V means smaller conductors can be used. When the generator spins at 1500rpm (revolutions per minute), the output frequency is 50Hz. N 120 f / P P 120 f / N 120 * 50 Hz / 1500 4. The generator has 4 poles per phase. Since it is an even number, the generator is a synchronous generator. Prime is the Apparent Power S in kVA that the generator set is capable of providing for an unlimited number of hours per year. In this case 600kVA. But as a Standby Generator (Emergency) operated less than 500 hours/year, the apparent power S is 660kVA. Current is 1003A. This is the rated current that can be supplied to the building at 380/220V. S √(3) V_LINE I_LINE I_LINE S / (√(3) V_LINE) 660kVA / ( √(3) * 380V) 1003A Power factor 0.8 lagging, which means at worst case the loads attached to it can have a power factor greater than 0.8. Power factor P / S. P S * pf 660kVA * 0.8 528kW The Real Power P or W loads the generator can supply are 528kW. So it can supply 5280 100W light bulbs, for example. If power factor is 1, 660kW could be supplied. There should be an electrical switchboard close to the generator, which will have labels showing how power is fed throughout the building. Everything else is specific to the device (Model, Serial, etc). Probably too much information for you, but when you are trying to understand something too much is better than too little.
Q:can u give me a job description power plant operator using diesel ingine
Diesel Motor turns a AC Generator. Diesel Motor turns a Water Pump, for Cooling.
Q:I am looking to save money on the electric/gas bill this winter and am considering a diesel generator to supply domestic power at 240 volts.Is this practical?
Home made electricity from a generator is more expensive than that from a supplier. They get huge bulk discount on fuel and their equipment is way more efficientt. But, and this is quite a big but. if you also use a heat exchanger on the exhaust and use the engine cooling system to heat your house, you win hands down. Think of it as either sightly more expensive electricity and free heating, or slightly more tricky heating and free electricity.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches