OPEN TYPE IMPORT CUMMINS DIESEL GENERATING SET DATA SHEET

Genset Model

Standby Power

Prime Power

Fuel Consumption

Overall Size

Weight

Fuel Tank Capacity

Engine Description

Alternator Model

KVA

KW

KVA

KW

100%    L/H

L x W x H (mm)

KG

L

 Model

Oil Capacity(L)

Coolant Capacity(L)

Stamford

ZOP11JK

11

8.8

10

8

2.1

1667x930x1247

550

160

X1.3-G2

4.5

15

PI044E

ZOP28JK

28

22

25

20

5.3

1667x930x1247

582

267

X2.5-G2

7

20

PI144E

ZOP38JK

38

30

35

28

7.4

1753x930x1250

875

267

X3.3-G1

6.8

20

PI144H

ZOP44JK

44

35

40

32

8.5

2115x1044x1516

1105

267

S3.8-G1

11

20

PI144J

ZOP55JK

55

44

50

40

10.6

2115x1044x1516

1120

267

S3.8-G4

11

20

UCI224D

ZOP66JK

66

53

60

48

12.7

2115x1044x1516

1105

267

S3.8-G7

11

20

UCI224E

ZOP90JK

90

72

82

66

17.5

2200x830x1250

1150

374

QSB5-G3

12.2

25

UCI224G

ZOP100JK

100

80

91

73

19.3

2200x955x1490

1272

374

QSB5-G4

12.2

25

UCI274C

ZOP110JK

110

88

100

80

21.2

2200x955x1490

1272

374

QSB5-G5

12.2

25

UCI274C

ZOP150JK

150

120

136

109

28.9

2200x955x1490

1290

374

QSB5-G6

12.2

29

UCI274E

ZOP175JK

175

140

150

120

31.8

2656x1100x1658

1550

374

QSB7-G3

18.9

33

UCI274F

ZOP200JK

200

160

180

144

38.2

2656x1100x1658

1560

374

QSB7-G4

18.9

33

UCI274G

ZOP220JK

220

176

200

160

42.4

2656x1100x1658

1572

374

QSB7-G5

18.9

33

UCI274H

ZOP250JK

250

200

225

180

47.7

3135x1100x1928

2300

374

QSL9-G2

26.5

35

UCDI274J

ZOP275JK

275

220

250

200

53

3135x1100x1928

2347

374

QSL9-G3

26.5

35

UCDI274K

ZOP330JK

330

264

300

240

63.6

2870x1120x1743

3150

374

QSL9-G5

26.5

35

HCI444D

ZOP500JK

500

400

450

360

96.5

3427x1500x2066

4121

1200

QSX15-G6

91

42

HCI544C

ZOP550JK

550

440

500

400

106.6

3340x1425x1772

5050

1200

QSX15-G8

91

42

HCI544C

ZOP550JK

550

440

500

400

107.3

3350x1280x1934

3940

1200

KTA19-G4

50

67

HCI544C

ZOP700JK

700

560

625

500

132.5

4047x1608x1942

5760

1700

VTA28-G5

83

80

HCI544F

ZOP810JK

810

650

750

600

159

4266x1879x2052

6420

1800

QSK23-G2

103

57

LVI634B

ZOP825JK

825

660

750

600

159

4047x1608x2187

6040

1800

VTA28-G6

83

80

LVI634B

ZOP880JK

880

704

800

640

171.7

4266x1879x2052

6680

1800

QSK23-G3

103

57

HCI634G

ZOP1000JK

1000

800

910

728

192.9

4297x1685x2079

6296

1800

QST30-G3

154

114

HCI634H

ZOP1100JK

1100

880

1000

800

212.3

4571x1785x2229

8350

1800

QST30-G4

154

106

HCI634J

ZOP1100JK

1100

880

1000

800

212

4470x1785x2229

8350

1800

KTA38-G5

199

135

HCI634J

ZOP1250JK

1250

990

1125

900

240.6

4470x1805x2244

8550

1800

QSK38-G2

170

106

HCI634K

ZOP1375JK

1375

1100

1250

1000

270

4470x1805x2244

8600

3000

QSK38-G5

170

106

LVI634G

ZOP1375JK

1375

1100

1250

1000

270.3

5283x2066x2233

10075

3000

KTA50-G3

177

152

LVI634G

ZOP1500JK

1500

1200

1375

1100

296.8

4783x2066x2233

9575

3000

QSK50-G3

235

245

PI734B

ZOP1675JK

1675

1340

1400

1120

297.2

5690x2033x2330

10324

3000

KTA50-G8

204

245

PI734C

ZOP1650JK

1650

1320

1500

1200

318

5690x2033x2330

10324

3000

KTA50-GS8

204

245

PI734C

ZOP1700JK

1700

1360

1540

1232

326.5

4783x2066x2233

9775

3000

QSK50-G4

235

245

PI734C

ZOP1825JK

1825

1460

1650

1320

349.8

4783x2066x2233

9775

3000

QSK50-G7

235

245

PI734D

ZOP2000JK

2000

1600

1875

1500

397.5

5900x2180x2600

14257

3000

QSK60-G3

280

242

PI734E

ZOP2250JK

2250

1800

2000

1600

433.5

6175x2286x2537

15510

3000

QSK60-G4

280

242

PI734F

ZOP2500JK

2500

2000

2000

1600

434

6225x2286x2537

15590

3000

QSK60-G13

280

242

PI734H

ZOP2500JK

2500

2000

2250

1800

6000x2660x2900

16500

3000

QSK60-G21

280

242

PI734H

ZOP2750JK

2750

2200

2500

2000

7200x2900x3830

2000

3000

QSK78-G18

466

295

LVSI804S

ZOP3000JK

3000

2400

2750

2200

7200x2900x3830

2000

3000

QSK78-G9

466

295

LVSI804S

 


Q: Are they cranked by a self starter? Is there such an immensely powerful self starter that runs off batteries and can start such a big engine?Or are they started by some gasoline powered motor?
A diesel engine is started (like an automobile) by turning over the crankshaft until the cylinders fire or begin combustion. The starting can be done electrically or pneumatically. Pneumatic starting was used for some engines. Compressed air was pumped into the cylinders of the engine until it gained sufficient speed to allow ignition, then fuel was applied to fire the engine. The compressed air was supplied by a smallauxiliary engine or by high pressure air cylinders carried by the locomotive. Electric starting is now standard. It works the same way as for an automobile, with batteries providing the power to turn a starter motor which turns over the main engine. In older locomotives fitted with DC generators instead of AC alternators, the generator was used as a starter motor by applying battery power to it.
Q: i wan't to make a small diesel generator. I've access to all of the machines.which are needed in this project.i know about how the engine works.i don't know how piston rings and piston seals the combustion chamber,how to make them.how much power will my generator will generate.i wan't to make this generator for my PC.
With respect, you're actually asking how to design and build your own engine. There are entire books on the subject, and you need plenty of diagrams as well. That's far beyond the scope of an answer on here. But if all you need is a 12v regulated dc power supply why not just get a model car or boat engine and see if you can hook it up to a car alternator from a scrapped vehicle via a suitable pulley gearing? It certainly won't be quiet though, and you'll need to ensure that the engine is either fan or water cooled and that there's a suitable exhaust outlet. Model diesel engines aren't very large, but there are larger scale copies of the old British Mills engine design made in India, and also various websites which give you details or sell you plans on how to build your own. Usually they have lapped pistons so don't need the complication of piston rings.
Q: Can you estimate the amount each year in CA.?What are the concerns/issues related to this application.
many years ago, when Bank of America needed such, the choice was between diesel or jet turbine. the money was about the same. the needed load was better met by diesel at that time. diesel and turbine fuel storage does not run the risk of leaking. in addition, the generators are used several times a year, during periods of high demand, as requested by PGE, for which the bank gets a reduced rate on it's electricity all year round. after the Loma Prieta quake, the bank came within 6 hours of running out of fuel for the generators.
Q: And WHY?
definitely okorder
Q: Does any one know the best way to go about have an entire house run off of a generator? Mostly likely over periods of no great than two weeks. But it needs to supply a Washer/Dryer, Central A/C, Water Heater, and all of the basics of a smaller house. I did the math and the math says the max I will need is apprx 13,500W. I've done a lot of research on portable, residential, and even green energy, but I am having trouble finding the best way to go about powering a house continually. I need something relatively quiet, or something I can run a ways from the house.And lastly one more curve ball, this is for west TX, so there's not too much rain, especially these days. But it is a desert atmosphere, so I need a way to keep it out of the elements. Any suggestions? Well ventilated shed maybe? Thanks!
Look at getting a 30KW, you want at least a 50% margin so there will be no overload threshhold to worry about. You never want to have a generator running close to capacity. Depending on your budget you may want to think about hydrogen fuel cells that are supplied by the generator and/or solar panels. Fuel cells will make for a vastly smaller carbon footprint and extend the reliability factor of your generator when used in conjunction with the solar panels. Natural gas is the best. If you don't have that propane is your other option. I don't believe there are any that will run on vegetable oil or biofuels yet, if there are they'll be expensive and you really don't want something that will require a specialist when it breaks down in west TX. Most whole-house standby generators have attenuated cabinets meaning they are insulated from the elemets and for noise management. Not to worry. You will want to educate yourself in basic maintenance and keep an ample stock of air filters for the engine, a dusty environment will play havoc with your generator. If you want to live off of the grid there are other ways to do it, if you are homesteading a plat with more than 5 acres you can get a turbine (windmill) as well. It will be cheaper in the long run to just have electrical service, but if logistics (no grid to tie into) prohibit this think about the options I mentioned. Good luck.
Q: I intend to buy Diesel Generator sets in USA but the problem is that the Generator sets available in USA are 50/60Hz /1800rpm, pf 1.0 , 277/480V whereas in my country the Frequency is 50Hz , Voltage is 220/380V and power factor is 0.8. What shall I do to convert the US spec's to what is my requirement.
You can adjust the frequency to 50HZ by running the generator at a speed lower than 1800rpm., that is 1500 rpm. At this speed check the terminal voltage. The voltage can be adjusted to 380 volts using the potentiometer adjustment on the generator panel. The 220 volts can be obtained by using a parallel connection assuming that the generator is wye connected. Actually, the voltage of 380 volts to neutral is 219.39 volts, which is approximately 220 volts. Hence, you may not have to reconnect the generator terminals. The difference in P.F. will not matter much.
Q: Can someone please tell me what is the piston ring cap is for the 186FA Diesel Engine 10hp, fitted into the powermate PM6100DS / 6KW Generator.
Just about all the rings you purchase new today come pre-gapped to the correct tolerance, just like spark plugs. Way in the past, of course back then it was necessary to check the gap. With such a small engine 1/16 is plenty.
Q: I would like to idle my 1981 mercedes benz 300sd for about 4 to 8 hours a day. will i hurt my car somehow if i do this?i am buring diesel to generate powers to charge my battery bank, so i have power for my power tools, it's hard to explain
hi it makes no damage at all if ur car is idle for even more than 5 hours and 2ndly u doing just for charging itsbetter u make a 1 mile round its sufficient for it to charge
Q: Design the logic circuit for starting an emergency diesel generator. For the generator to start, the generator must be disconnected from the bus, there must be sufficient start air pressure, and the fuel tank must indicate there is oil. When these conditions are met, then the diesel may be started. Presume there are senors to determine these values.
This is just an and gate function. When the outputs of all the sensors are true and a start command is present, the output of the gate will go high to allow the engine to start.
Q: here in the town i live in we recently had an avalanche take out power transmission lines from our hydro dam in the time it takes them to repair those 90% of our power is coming from diesel generators(you should have cringed there) causing the price per kWh to go up 500% for what might be the next 3 months.currently i make enough that i can live with a bill 5 times higher than im used to, but a couple of years ago that would have got me kicked out of my apartment because there was no way in hell i could find an extra 300 bucks a month with a week or two notice.its been a big deal here, but we are notorious complainers, so im wondering if that situation would cause you to write letters to editors and complain to everyone who will listen all day long?
My Electric bill in high season is around $350/Month If it was 500% more it would be $1750/Month If it was me I would tell them what to do with their power and use candles, or move in with someone else.