• Cummins Brand Generator Diesel 500K Watt System 1
Cummins Brand Generator Diesel 500K Watt

Cummins Brand Generator Diesel 500K Watt

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Unit unit
Supply Capability:
100 Units per Month unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Machine parameters:

#Rated voltage (V) 400/230

#Wiring three-phase four-wire

#Power factor 0.8 (lag)

#Cooling System Water cooled

#Highly elastic rubber shock absorbers damping system

#Integrated settlement of purchase

#Steady state voltage regulation rate% ≤ ± 1

#Voltage transient adjustment rate% ≤ ± 20

#Voltage stabilization time S ≤ 1.5

#Voltage fluctuation rate% ≤ ± 0.5

#Current steady-state adjustment rate% ≤ 5

#The current transients adjustment rate% ≤ ± 10

#Current stabilization time S ≤ 5

#Current volatility% ≤ 0.5

#The warranty period is one year or one thousand hours, whichever occurs first. (GB)

 

The engines of various parameters:

#Model: KTA19-G3A power (KW): 504

#Fuel: diesel Speed mode: Electronic

#Diesel consumption (Liter / hr) 102.85 Oil Capacity (L) 50

#Displacement (L) 19 Speed (m / min) 1500

#Compression ratio 13.9:1 Bore / Stroke: 159/159

#Type: Four-stroke, six-cylinder, in-line cooling method water-cooled

#Start way: electric start Power DV24V

#Intake: exhaust gas turbocharger cold ignition sequence 1-5-3-6-2-4

 

The alternator parameters

#Model the: HX5FS power (KW): 500

#Excitation mode: brushless excitation frequency (HZ) 50

#Cooling: cooling voltage regulation system: AVR automatic voltage regulator

#Protection class: IP Insulation class: H

#Overload capacity: 1.5IE not less than the a 2min short-time overcurrent: 3 ~ 5 le not less than 5S

Q: if a diesel generator(say of negligible mass) is used to power an electric car powered by an electirc motor how efficient will it be when compared to a car that uses an i.c engine thats uses diesel directly?
This Site Might Help You. RE: how efficient are diesel generators?pls read more below.? if a diesel generator(say of negligible mass) is used to power an electric car powered by an electirc motor how efficient will it be when compared to a car that uses an i.c engine thats uses diesel directly?
Q: What will be the effect of ambient temperature on diesel generators
Fully automatic diesel generator sets are more expensive than conventional diesel engines with the same brand, configuration and power as the unit is equipped with a fully automated system.
Q: I am purchasing a LARGE MOBILE TRAILER to be my mobile workshop. I wonder which would best regarding fumes and general maintenance. Onan approx. 7000w is my preffered choice at this point.
well gas is a much cleaner burn and gives off no fumes but it does give off alot of moisture and you will find it will quite literally rain in your trailer on cold days. also when gas evapourates from liquid to gas it absorbs the ambient heat and freezes so in really cold weather the gas bottle freezes and the heater doesn work. the only real benefit from deisel is its freezing temp and the fact that you will always have some if you run out in the van but unfortunately they do need regular servicing as they do block the filters and start to pulse and when they do that they give out blowms of smoke which isnt pleasant
Q: I know that they could re-surface to re-establish a normal supply of air but what about when they were under attack and couldnt surface for long periods of time,wouldnt those engines use up a lot of the oxygen inside the sub?
Diesel submarines that were used during WWII actually have two different types of engines. The main Diesel engine, and an electric one. When a boat submerges they use the electric engines only, these usually only have an hour or so worth of power. Once they resurface they fire up the diesel. They are stuck on the surface until the electric engines are re-charged by the diesel. Prior to the advent of the nuclear submarine (which can remain submerged almost indefinitely), the submarine spent most of its time on the surface like any other ship.
Q: I have a 3 bedroom / 1 bath home. It is just 2 of us in the house. Also, I've heard that there is way to plug your generator into any wall outlet and it will charge your whole house. Any truth to this?
A 13 K will handle most homes, and NO you can,t plug it into a outlet, it has to be connected to the breaker box with a automatic disconnect, [BY Law] so when the gen kicks in the power line is disconnected, A Diesel powered gen will run for 3 months on 1,000 gal of fuel,
Q: about diesel generator
the air cooled one is a duitz air diesel . they are very reliable about the only maintenance it will ever need is filters and the cooling fins cleaned from time to time. it is lighter than a water cooled version and freezing will not hurt it.
Q: For hydropower how much MWh can be generated with same capacity plant?. (Because plant never run for 24 hours of the day we need a factor to calculate above value)
They sure do run 24 hours a day. Maybe not 365 days a year - allow maybe 1 week down time for maintenance. If you have a particular generator in mind, look up the operating specs for it.
Q: Example 1:A GP38-2 has a 2000 HP prime mover diesel engine.What are the horsepower ratings of the electric motors geared to the axle? [4 electric motors; 1 on each axle how much HP?]Example 2:An SD38-2 has a 2000 HP prime mover diesel engine.What are the horsepower ratings of the electric motors geared to the axle? [6 electric motors; 1 on each axle how much HP?]I know the tractive effort of the SD unit would be higher, but with 2 more motors on the axles, does it have more horsepower also?
This Site Might Help You. RE: Diesel locomotive horsepower question? Example 1: A GP38-2 has a 2000 HP prime mover diesel engine. What are the horsepower ratings of the electric motors geared to the axle? [4 electric motors; 1 on each axle how much HP?] Example 2: An SD38-2 has a 2000 HP prime mover diesel engine. What are the horsepower ratings of the
Q: Aside from the fact that they just had a massive natural disaster and there resources are stretched to say the least, what is main reason they cant get the reactor under control?From what I've heard it's not receiving enough power to maintain cooling system so it can maintain controlled fission.In my limited understanding it seems the plant survived relatively unscathed other than there diesel generators being flooded/destroyed. The plant is currently on battery backup's which I assume are relatively large and cant just be switched out to maintain the cooling system. Is it just an issue of supplying enough power for the cooling system? Couldn't they park the the USS Ronald Reagan off shore there and borrow some power until stabilized, considering you could power a sizable city off its reactor?
the tidal wave was created by a nuke detonated in the ocean. They might have had a bomb inside the nuke plant. Now think of tidal waves and attacks against nuclear plants. If a whole nuke plant goes up you'll have nothing over 1,000 mile radius. It's time to close these plants.
Q: Hello, I am putting an HHO generator, which is metal plates in water in pvc pipe, into my small pickup truck. I am having a bit of trouble finding an EFIE unit though, which is the boy that goes in line in front of the 02 sensor, to give it a bit more juice and stop it from dumping more gas in when it thinks there is not enough air (but way too much HHO) in the system.Are there any automotive forums that you all would direct me to? And if not, are there any manufacturers of finished EFIE units, or even kits to build them, on the internet or elsewhere for me to utilize?I want to get this done before I leave for college. Gas prices suck!
Be very about a leak as it is very dangerous. H will leak through most hoses. U should also a back fire pot to prevent a back fire from fireing into your tank.
Our company wins markets with honest working style, outstanding service attitude as well as business idea of perfect quality and competitive prices. Our products are deeply renowned by perfect quality, best aftersales service.

1. Manufacturer Overview

Location Shandong,China
Year Established 2004
Annual Output Value Above US$100 Million
Main Markets 16.00% Western Europe
12.00% South America
10.00% South Asia
10.00% Southeast Asia
9.00% Mid East
6.00% Oceania
6.00% Africa
6.00% Eastern Asia
6.00% North America
6.00% Northern Europe
5.00% Eastern Europe
5.00% Southern Europe
2.00% Domestic Market
1.00% Central America
Company Certifications HACCP;ISO 9001:2000;CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port QINGDAO,YANTAI
Export Percentage 81% - 90%
No.of Employees in Trade Department 21-50 People
Language Spoken: English, Chinese, Spanish, Russian
b) Factory Information
Factory Size: 10,000-30,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered
Product Price Range Low and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords