Silent Type Perkins Diesel Generating Set

Below data sheet is our silent type diesel generator set,this type genset is suitable for those places where with dense population or strict requirements on noise.

SILENT TYPE PERKINS DIESEL GENERATING SET DATA SHEET

Genset Model

Standby Power

Prime Power

Fuel Consumption

Overall Size

Weight

Fuel Tank Capacity

Engine Description

Alternator Model

KVA

KW

KVA

KW

100%    L/H

L x W x H (mm)

KG

L

 Model

Oil Capacity(L)

Coolant Capacity(L)

Stamford

ZOP10PKS

10

8

9

7

2.6

2200x1033x1304

896

160

403A-11G1

4.9

5.2

LSA40VS1

ZOP10PKS

10

8

9

7

2.6

2200x1033x1304

896

160

403D-11G

4.9

5.2

LSA40VS1

ZOP14PKS

14

11

13

10

3.67

2200x1033x1304

956

160

403D-15G

6

6

LSA40VS2

ZOP14PKS

14

11

13

10

3.48

2200x1033x1304

956

160

403A-15G1

6

6

LSA40VS2

ZOP16PKS

16

13

15

12

3.48

2200x1033x1304

956

160

403A-15G2

6

6

LSA40S3

ZOP22PKS

22

18

20

16

5.3

2200x1033x1304

1070

160

404D-22G

10.6

7

LSA40M5

ZOP22PKS

22

18

20

16

5.3

2200x1033x1304

1070

160

404A-22G1

10.6

7

LSA40M5

ZOP30PKS

30

24

27

22

6.7

2200x1033x1304

1087

160

404D-22TG

10.6

9.3

LSA42.3VS2

ZOP33PKS

33

26

30

24

6.98

2300x1133x1376

1270

221

1103A-33

7.9

10.2

LSA42.3VS3

ZOP50PKS

50

40

45

36

10.6

2300x1133x1376

1407

221

1103A-33T/DK83398S

7.9

10.2

LSA42.3M7

ZOP65PKS

65

52

60

48

13.8

2300x1133x1376

1434

221

1104C-44TG2

8

13

LSA42.3L9

ZOP65PKS

65

52

60

48

13.8

2300x1133x1376

1434

221

1103A-33T/DK83399S

7.9

10.2

LSA42.3L9

ZOP75PKS

73

58

65

52

14.8

2300x1133x1376

1547

221

1104A-44TG1

8

13

LSA44.3S2

ZOP88PKS

88

70

80

64

18.4

2300x1133x1376

1560

221

1104A-44TG2

8

13

LSA44.3S3

ZOP88PKS

88

70

80

64

18.4

2300x1133x1376

1560

221

1104C-44TAG1

8

12.6

LSA44.3S3

ZOP100PKS

100

80

90

72

20.5

2700x1133x1666

1735

300

1104C-44TAG2

8

12.6

LSA44.3S4

ZOP110PKS

110

88

100

80

24

2700x1133x1666

1750

300

1104C-44TAG2

8

12.6

LSA44.3S5

ZOP150PKS

150

120

135

108

29.9

3600x1333x2040

2864

685

1106A-70TG1

16.5

21

LSA44.3M8

ZOP158PKS

158

126

142

115

39.7

3600x1333x2040

2864

685

1106D-E70TAG2

16.5

21

LSA44.3L10

ZOP165PKS

165

132

150

120

33.4

3600x1333x2040

2864

685

1106A-70TAG2

16.5

21

LSA44.3L10

ZOP175PKS

175

140

160

128

42.3

3600x1333x2040

2864

685

1106D-E70TAG3

16.5

21

LSA44.3L12

ZOP200PKS

200

160

180

144

41.6

3600x1333x2040

2904

685

1106A-70TAG3

16.5

21

LSA46.3S2

ZOP200PKS

200

160

180

144

49.3

3600x1333x2040

2959

685

1106A-E70TAG4

16.5

21

LSA46.3S2

ZOP220PKS

220

176

200

160

45.8

3600x1333x2040

2959

685

1106A-70TAG4

16.5

21

LSA46.3S3

ZOP220PKS

220

176

200

160

44.6

4100x1490x2000

4500

1100

1506A-E88TAG1

41

29.6

LSA46.3S3

ZOP250PKS

250

200

225

180

48.6

4100x1490x2000

4500

1100

1506A-E88TAG2

41

29.6

LSA46.3S4

ZOP275PKS

275

220

250

200

50

4100x1490x2000

4500

1100

1506A-E88TAG3

41

29.6

LSA46.3S5

ZOP300PKS

300

240

275

220

60.2

4100x1490x2000

4600

1100

1506A-E88TAG4

41

33.2

LSA46.3M7

ZOP330PKS

330

264

300

240

64.9

4100x1490x2000

4600

1100

1506A-E88TAG5

41

33.2

LSA46.3M8

ZOP400PKS

400

320

350

280

70

4500x1583x2200

4724

1200

2206A-E13TAG2

40

51.4

LSA46.3L11

ZOP400PKS

400

320

350

280

70

4500x1583x2200

4724

1200

2206C-E13TAG2

40

51.4

LSA46.3L11

ZOP450PKS

450

360

400

320

82.7

4500x1583x2200

4860

1200

2206A-E13TAG3

40

51.4

LSA47.2S4

ZOP450PKS

450

360

400

320

82.7

4500x1583x2200

4860

1200

2206C-E13TAG3

40

51.4

LSA47.2S4

ZOP500PKS

500

400

450

360

95.6

4700x1583x2200

5039

1200

2506A-E15TAG1

62

58

LSA47.2S5

ZOP500PKS

500

400

450

360

95.6

4700x1583x2200

5039

1200

2506C-E15TAG1

62

58

LSA47.2S5

ZOP550PKS

550

440

500

400

106

4700x1583x2200

5166

1200

2506A-E15TAG2

62

58

LSA47.2M7

ZOP550PKS

550

440

500

400

106

4700x1583x2200

5166

1200

2506C-E15TAG2

62

58

LSA47.2M7

ZOP650PKS

650

520

600

480

126.6

4700x1583x2200

5993

1450

2806C-E18TAG1A

87

61

LSA47.2L9

ZOP660PKS

660

528

600

480

126.6

4700x1583x2200

5993

1450

2806A-E18TAG1A

87

61

LSA47.2L9

ZOP700PKS

700

560

650

520

129.3

4700x1583x2200

6041

1450

2806A-E18TAG2

87

61

LSA49.3S4

ZOP825PKS

825

660

750

600

152.3

6058x2438x2591

10370

1800

4006-23TAG2A

113.4

140

LSA49.3M8

ZOP880PKS

880

704

800

640

171.8

6058x2438x2591

10400

1800

4006-23TAG3A

113.4

140

LSA49.3M8

ZOP1000PKS

1000

800

900

720

188

6058x2438x2591

11667

1400

4008TAG1A

153

234

LSA49.3L9

ZOP1100PKS

1100

880

1000

800

215.2

6058x2438x2591

12030

1400

4008TAG2

153

234

LSA49.3L10

ZOP1100PKS

1100

880

1000

800

215.2

6058x2438x2591

12030

1400

4008TAG2A

153

234

LSA49.3L10

ZOP1250PKS

1250

1000

1125

900

237.2

6058x2438x2591

12310

1400

4008-30TAG3

153

234

LSA50.2M6

ZOP1375PKS

1375

1100

1250

1000

258.1

12192x2438x2896

17950

3000

4012-46TWG2A

177

187

LSA50.2M6

ZOP1500PKS

1500

1200

1375

1100

279.1

12192x2438x2896

18205

3000

4012-46TWG1A

177

274

LSA50.2L7

ZOP1500PKS

1500

1200

1375

1100

279.1

12192x2438x2896

18205

3000

4012-46TWG3A

177

187

LSA50.2L7

ZOP1600PKS

1600

1280

1500

1200

299

12192x2438x2896

18435

3000

4012-46TWG4A

177

187

LSA50.2L8

ZOP1650PKS

1650

1320

1500

1200

299

12192x2438x2896

18435

3000

4012-46TAG2A

177

274

LSA50.2L8

ZOP1875PKS

1875

1500

1688

1350

367.3

12192x2438x2896

19200

3000

4012-46TAG3A

177

274

LSA52.3S5

ZOP2000PKS

2000

1600

1850

1480

381.3

12192x2438x2896

21780

3000

4016TAG1A

237

368

LSA52.3S5

ZOP2000PKS

2000

1600

1850

1480

381.3

12192x2438x2896

21780

3000

4016-61TRG1

237

376

LSA52.3S5

ZOP2250PKS

2250

1800

2000

1600

434

12192x2438x2896

21875

3000

4016TAG2A

237

368

LSA52.3S6

ZOP2250PKS

2250

1800

2000

1600

422

12192x2438x2896

21875

3000

4016-61TRG2

237

376

LSA52.3S6

ZOP2500PKS

2500

2000

2250

1800

467.6

12192x2438x2896

22900

3000

4016-61TRG3

237

376

LSA52.3L9

 


Q:If i had a remote alaskan town of 1000 residents, how much power would I need to generate to run the whole town. Would a diesel generator work?
You need kilowatts, not kilowatt hours. The amount of power you need varies depending on who turns on what at any given time, and especially on what kind of equipment you are using in the mine. Mines can use huge amounts of electric power. Assuming you are talking about a fairly small mine, you are probably looking at something around 500 kilowatts peak demand. This would require a small power plant. You may be able to get a diesel generator this size, but it would be more efficient to use several smaller generators. This would allow you to shut down some generators to vary the output to meet the varying demand.
Q:I am trying to find the value on a generator we’re trying to sell which is becoming a real headache since the thing was made in China. All I know about it is it was made by Shanghai Tractor and Internal Combustion Engine Corp and it’s a 20kw diesel generator. It’s about 5 years old but has only been used once since we purchased it. How would I go about finding the value for this generator? I need to have it sold as soon as possible.
Companies like China Star have become famous for diesel generators, so being from China is not a negative. Just look up any US made generator and reduce by about %30 to get value. I think a US generator of that size, which is sufficient for a whole house, should run about $2500. So as used slightly, I would start around $1800 I think. But you may have to come down to $1000 if the market happens to be slow. Check on Craigslist to compare. I am only guessing off the top of my head. It is contractors who buy them the most, and few people are building right now.
Q:How much would it typically cost to rent a 6000-8000watt diesel generator for a week? I know no one here probably knows for sure, so I'm just looking for ballpark figures. Thanks.
You can expect to spend between $60-$80 per day for a diesel generator.
Q:Diesel generator selection criteria?
Diesel generators are widely used in telecommunications, finance, emergency power supply departments, hospitals, schools, commercial departments
Q:I could see how it could benefit certian classes of commercial trucks,heavy equitment;ect!but what about passanger cars though?
well look at ethanol for instance it damages fiberglass plugs the fuel system over time many in the marine world have allready had the issue with ethanol being added to diesel. hybrids have no true savings. a good tuneup and remapping of the ineffecient computer a cold air intake good flowing exhuast and proper tire inflation per tire manufacturer not vehicle manufacturer can make any gas vehicle far more effieceint
Q:I am designing the system to produce electricity for a computer room with 40 PC and 40 LCD screens. The needed power is about 15 KW (20 hp). My system consists of a compressor, a compressed air tank, a turbocharger and a mini gas turbine. I will talk a little bit about the operation: the air is released from the tank and driven by ducting system to turbocharger, at which the air flow is through turbocharger and run turbine to produce electricity. I have searched in internet many times about the turbine but still have no fit one. Can anybody suggest me one? And the turbocharger too if you don't mind. I really need all the details about both of them for calculations.
This is a very inefficient way to produce electricity. Where are you getting the power to run the compressor? Use that to run the computers. Or use that charge batteries that will run an inverter. Or use a diesel generator. .
Q:1. Both fans are running2.Both fan is running 3.Both diesel generators were serviced 4.Both diesel generator was serviced5.Both diesel generators had been serviced. / Has been servicedWhich one is correct, and why?
These three are correct - 1. Both fans are running (are, because both fans is plural) 3.Both diesel generators were serviced (were, because generators is plural) 5.Both diesel generators had been serviced (you can also say have been serviced, if they've been serviced recently. EDIT.@Diane: None of them is singular; therefore is correct.and the question doesn't concern punctuation.
Q:can't those nuclear material in japan be kept inside a container that is not affected by it like lead?or shifted to an isolated location.
When an earthquake strikes a reactor, it detects and stops working. Due to continuous heating in the reactor, it needs to be cooled down. This is done by electricity-run generators. But due to power crisis aftermath the tsunami, these generators failed. Then diesel generators took their place. These too failed to work. And at the end, battery-run generators were applied. These also turned ineffective. Now no measure can be used to cool down the reactors. Reactors will probably blast due to heating up and radioactive material will spread in the sky. Sorry, but your suggestion is not easy to apply.
Q:I live in a location without municipal water supply. I could buy a natural gas generator, and hire an electrician to connect it to my breaker box, but I believe there is a way to connect solar panels to a battery system to provide enough power for my 220 volts submerged pump. I have 2 horses, 24 chickens, 2 dogs, 4 cats, 3 parakeets, and 3 people that need water in the event of a hurricane, national power grid attack,etc. There are solar powered generators advertised, but they are not powerful enough for 220. Also, my whole neighborhood of over 200 homes all lives off their own water wells, and we all suffered during hurricane Ike: 10 days without a water supply.
For that heavy a load, I'd think that a gasoline or diesel generator might be more appropriate. While you could possibly set up a bank of solar-charged batteries to power a 220-volt inverter, the power requirements could make that approach cost-prohibitive.
Q:If you were talking on the phone to someone and dropped the phone into a bathtub filled with water would they get electrocuted? Does it matter if it's wireless or not?
this is a gd ? it depends on diff kinds of phones but i think mostly no because there not high

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords