Below data sheet is our silent type diesel generator set,this type genset is suitable for those places where with dense population or strict requirements on noise.
SILENT TYPE PERKINS DIESEL GENERATING SET DATA SHEET | ||||||||||||
Genset Model | Standby Power | Prime Power | Fuel Consumption | Overall Size | Weight | Fuel Tank Capacity | Engine Description | Alternator Model | ||||
KVA | KW | KVA | KW | 100% L/H | L x W x H (mm) | KG | L | Model | Oil Capacity(L) | Coolant Capacity(L) | Stamford | |
ZOP10PKS | 10 | 8 | 9 | 7 | 2.6 | 2200x1033x1304 | 896 | 160 | 403A-11G1 | 4.9 | 5.2 | LSA40VS1 |
ZOP10PKS | 10 | 8 | 9 | 7 | 2.6 | 2200x1033x1304 | 896 | 160 | 403D-11G | 4.9 | 5.2 | LSA40VS1 |
ZOP14PKS | 14 | 11 | 13 | 10 | 3.67 | 2200x1033x1304 | 956 | 160 | 403D-15G | 6 | 6 | LSA40VS2 |
ZOP14PKS | 14 | 11 | 13 | 10 | 3.48 | 2200x1033x1304 | 956 | 160 | 403A-15G1 | 6 | 6 | LSA40VS2 |
ZOP16PKS | 16 | 13 | 15 | 12 | 3.48 | 2200x1033x1304 | 956 | 160 | 403A-15G2 | 6 | 6 | LSA40S3 |
ZOP22PKS | 22 | 18 | 20 | 16 | 5.3 | 2200x1033x1304 | 1070 | 160 | 404D-22G | 10.6 | 7 | LSA40M5 |
ZOP22PKS | 22 | 18 | 20 | 16 | 5.3 | 2200x1033x1304 | 1070 | 160 | 404A-22G1 | 10.6 | 7 | LSA40M5 |
ZOP30PKS | 30 | 24 | 27 | 22 | 6.7 | 2200x1033x1304 | 1087 | 160 | 404D-22TG | 10.6 | 9.3 | LSA42.3VS2 |
ZOP33PKS | 33 | 26 | 30 | 24 | 6.98 | 2300x1133x1376 | 1270 | 221 | 1103A-33 | 7.9 | 10.2 | LSA42.3VS3 |
ZOP50PKS | 50 | 40 | 45 | 36 | 10.6 | 2300x1133x1376 | 1407 | 221 | 1103A-33T/DK83398S | 7.9 | 10.2 | LSA42.3M7 |
ZOP65PKS | 65 | 52 | 60 | 48 | 13.8 | 2300x1133x1376 | 1434 | 221 | 1104C-44TG2 | 8 | 13 | LSA42.3L9 |
ZOP65PKS | 65 | 52 | 60 | 48 | 13.8 | 2300x1133x1376 | 1434 | 221 | 1103A-33T/DK83399S | 7.9 | 10.2 | LSA42.3L9 |
ZOP75PKS | 73 | 58 | 65 | 52 | 14.8 | 2300x1133x1376 | 1547 | 221 | 1104A-44TG1 | 8 | 13 | LSA44.3S2 |
ZOP88PKS | 88 | 70 | 80 | 64 | 18.4 | 2300x1133x1376 | 1560 | 221 | 1104A-44TG2 | 8 | 13 | LSA44.3S3 |
ZOP88PKS | 88 | 70 | 80 | 64 | 18.4 | 2300x1133x1376 | 1560 | 221 | 1104C-44TAG1 | 8 | 12.6 | LSA44.3S3 |
ZOP100PKS | 100 | 80 | 90 | 72 | 20.5 | 2700x1133x1666 | 1735 | 300 | 1104C-44TAG2 | 8 | 12.6 | LSA44.3S4 |
ZOP110PKS | 110 | 88 | 100 | 80 | 24 | 2700x1133x1666 | 1750 | 300 | 1104C-44TAG2 | 8 | 12.6 | LSA44.3S5 |
ZOP150PKS | 150 | 120 | 135 | 108 | 29.9 | 3600x1333x2040 | 2864 | 685 | 1106A-70TG1 | 16.5 | 21 | LSA44.3M8 |
ZOP158PKS | 158 | 126 | 142 | 115 | 39.7 | 3600x1333x2040 | 2864 | 685 | 1106D-E70TAG2 | 16.5 | 21 | LSA44.3L10 |
ZOP165PKS | 165 | 132 | 150 | 120 | 33.4 | 3600x1333x2040 | 2864 | 685 | 1106A-70TAG2 | 16.5 | 21 | LSA44.3L10 |
ZOP175PKS | 175 | 140 | 160 | 128 | 42.3 | 3600x1333x2040 | 2864 | 685 | 1106D-E70TAG3 | 16.5 | 21 | LSA44.3L12 |
ZOP200PKS | 200 | 160 | 180 | 144 | 41.6 | 3600x1333x2040 | 2904 | 685 | 1106A-70TAG3 | 16.5 | 21 | LSA46.3S2 |
ZOP200PKS | 200 | 160 | 180 | 144 | 49.3 | 3600x1333x2040 | 2959 | 685 | 1106A-E70TAG4 | 16.5 | 21 | LSA46.3S2 |
ZOP220PKS | 220 | 176 | 200 | 160 | 45.8 | 3600x1333x2040 | 2959 | 685 | 1106A-70TAG4 | 16.5 | 21 | LSA46.3S3 |
ZOP220PKS | 220 | 176 | 200 | 160 | 44.6 | 4100x1490x2000 | 4500 | 1100 | 1506A-E88TAG1 | 41 | 29.6 | LSA46.3S3 |
ZOP250PKS | 250 | 200 | 225 | 180 | 48.6 | 4100x1490x2000 | 4500 | 1100 | 1506A-E88TAG2 | 41 | 29.6 | LSA46.3S4 |
ZOP275PKS | 275 | 220 | 250 | 200 | 50 | 4100x1490x2000 | 4500 | 1100 | 1506A-E88TAG3 | 41 | 29.6 | LSA46.3S5 |
ZOP300PKS | 300 | 240 | 275 | 220 | 60.2 | 4100x1490x2000 | 4600 | 1100 | 1506A-E88TAG4 | 41 | 33.2 | LSA46.3M7 |
ZOP330PKS | 330 | 264 | 300 | 240 | 64.9 | 4100x1490x2000 | 4600 | 1100 | 1506A-E88TAG5 | 41 | 33.2 | LSA46.3M8 |
ZOP400PKS | 400 | 320 | 350 | 280 | 70 | 4500x1583x2200 | 4724 | 1200 | 2206A-E13TAG2 | 40 | 51.4 | LSA46.3L11 |
ZOP400PKS | 400 | 320 | 350 | 280 | 70 | 4500x1583x2200 | 4724 | 1200 | 2206C-E13TAG2 | 40 | 51.4 | LSA46.3L11 |
ZOP450PKS | 450 | 360 | 400 | 320 | 82.7 | 4500x1583x2200 | 4860 | 1200 | 2206A-E13TAG3 | 40 | 51.4 | LSA47.2S4 |
ZOP450PKS | 450 | 360 | 400 | 320 | 82.7 | 4500x1583x2200 | 4860 | 1200 | 2206C-E13TAG3 | 40 | 51.4 | LSA47.2S4 |
ZOP500PKS | 500 | 400 | 450 | 360 | 95.6 | 4700x1583x2200 | 5039 | 1200 | 2506A-E15TAG1 | 62 | 58 | LSA47.2S5 |
ZOP500PKS | 500 | 400 | 450 | 360 | 95.6 | 4700x1583x2200 | 5039 | 1200 | 2506C-E15TAG1 | 62 | 58 | LSA47.2S5 |
ZOP550PKS | 550 | 440 | 500 | 400 | 106 | 4700x1583x2200 | 5166 | 1200 | 2506A-E15TAG2 | 62 | 58 | LSA47.2M7 |
ZOP550PKS | 550 | 440 | 500 | 400 | 106 | 4700x1583x2200 | 5166 | 1200 | 2506C-E15TAG2 | 62 | 58 | LSA47.2M7 |
ZOP650PKS | 650 | 520 | 600 | 480 | 126.6 | 4700x1583x2200 | 5993 | 1450 | 2806C-E18TAG1A | 87 | 61 | LSA47.2L9 |
ZOP660PKS | 660 | 528 | 600 | 480 | 126.6 | 4700x1583x2200 | 5993 | 1450 | 2806A-E18TAG1A | 87 | 61 | LSA47.2L9 |
ZOP700PKS | 700 | 560 | 650 | 520 | 129.3 | 4700x1583x2200 | 6041 | 1450 | 2806A-E18TAG2 | 87 | 61 | LSA49.3S4 |
ZOP825PKS | 825 | 660 | 750 | 600 | 152.3 | 6058x2438x2591 | 10370 | 1800 | 4006-23TAG2A | 113.4 | 140 | LSA49.3M8 |
ZOP880PKS | 880 | 704 | 800 | 640 | 171.8 | 6058x2438x2591 | 10400 | 1800 | 4006-23TAG3A | 113.4 | 140 | LSA49.3M8 |
ZOP1000PKS | 1000 | 800 | 900 | 720 | 188 | 6058x2438x2591 | 11667 | 1400 | 4008TAG1A | 153 | 234 | LSA49.3L9 |
ZOP1100PKS | 1100 | 880 | 1000 | 800 | 215.2 | 6058x2438x2591 | 12030 | 1400 | 4008TAG2 | 153 | 234 | LSA49.3L10 |
ZOP1100PKS | 1100 | 880 | 1000 | 800 | 215.2 | 6058x2438x2591 | 12030 | 1400 | 4008TAG2A | 153 | 234 | LSA49.3L10 |
ZOP1250PKS | 1250 | 1000 | 1125 | 900 | 237.2 | 6058x2438x2591 | 12310 | 1400 | 4008-30TAG3 | 153 | 234 | LSA50.2M6 |
ZOP1375PKS | 1375 | 1100 | 1250 | 1000 | 258.1 | 12192x2438x2896 | 17950 | 3000 | 4012-46TWG2A | 177 | 187 | LSA50.2M6 |
ZOP1500PKS | 1500 | 1200 | 1375 | 1100 | 279.1 | 12192x2438x2896 | 18205 | 3000 | 4012-46TWG1A | 177 | 274 | LSA50.2L7 |
ZOP1500PKS | 1500 | 1200 | 1375 | 1100 | 279.1 | 12192x2438x2896 | 18205 | 3000 | 4012-46TWG3A | 177 | 187 | LSA50.2L7 |
ZOP1600PKS | 1600 | 1280 | 1500 | 1200 | 299 | 12192x2438x2896 | 18435 | 3000 | 4012-46TWG4A | 177 | 187 | LSA50.2L8 |
ZOP1650PKS | 1650 | 1320 | 1500 | 1200 | 299 | 12192x2438x2896 | 18435 | 3000 | 4012-46TAG2A | 177 | 274 | LSA50.2L8 |
ZOP1875PKS | 1875 | 1500 | 1688 | 1350 | 367.3 | 12192x2438x2896 | 19200 | 3000 | 4012-46TAG3A | 177 | 274 | LSA52.3S5 |
ZOP2000PKS | 2000 | 1600 | 1850 | 1480 | 381.3 | 12192x2438x2896 | 21780 | 3000 | 4016TAG1A | 237 | 368 | LSA52.3S5 |
ZOP2000PKS | 2000 | 1600 | 1850 | 1480 | 381.3 | 12192x2438x2896 | 21780 | 3000 | 4016-61TRG1 | 237 | 376 | LSA52.3S5 |
ZOP2250PKS | 2250 | 1800 | 2000 | 1600 | 434 | 12192x2438x2896 | 21875 | 3000 | 4016TAG2A | 237 | 368 | LSA52.3S6 |
ZOP2250PKS | 2250 | 1800 | 2000 | 1600 | 422 | 12192x2438x2896 | 21875 | 3000 | 4016-61TRG2 | 237 | 376 | LSA52.3S6 |
ZOP2500PKS | 2500 | 2000 | 2250 | 1800 | 467.6 | 12192x2438x2896 | 22900 | 3000 | 4016-61TRG3 | 237 | 376 | LSA52.3L9 |
- Q: Hello friends.I had to make a list of equipment for a civil construction company. Among the equipment were generator and diesel engine. For generator, i am very clear that it is used for alternate power generation in case of electricity un availability. What is the purpose of diesel engine? Where is is used? Guide me please.
- Just about every piece of equipment powered by an internal combustion engine found at a civil construction site is powered by a diesel engine. Things such as scrapers, loaders, track hoes, dozers, dump trucks, rollers, and even electric generators are powered with diesel engines.
- Q: i.e a house or a hospital.
- Gasoline or diesel. You can buy small generators for this. Average home would use a 2 kW typically, a 5kW if there is lots of AC and other large loads. But a hospital requires a much larger generator, and also a lot more reliablility, as well as automatic switchover. .
- Q: Frequency meter
- The frequency meter is used for measuring the frequency of an alternator or other equipments like variable frequency drives. It should be connected between two lines of a unit. Check for its voltage rating. The meter should be rated the same as the voltage rating of the line being measured. It could be used also for vhf and uhf frequency, digital or analog. So depending on your application, you have to specify its frequency range and voltage rating.
- Q: I have 6,500 gas generator to run two 12,500btu roof a/c units on my bus.Nothing but problem after problem with generator.I was advised to change unit out to diesel unit! Any advise on what size i should be looking for?
- If you love the roar of a diesel engine and the smell of diesel fuel then I guess that's the way to go, places like Camping World have technicians that can answer all your questions and will also sell and install the perfect unit for you.
- Q: Hello,I'm doing a research project that requires me to report on five ethical missteps made by engineers/staff at the Fukushima plant that caused the disaster. I'm having trouble with this research because most of the information i'm finding centers around the earthquake and subsequent tsunami that caused so much damage.Can anyone point me toward any human errors that centered around poor ethical judgement?
- If you just google human error fukushima you're going to get (a) a few articles from the summer of 2011; (b) a rash of articles from July, 2012; (c) a rash of articles from Oct-Nov, 2013; and (d) a rash of articles from last week (Feb 2014). Whether all will cite ethical missteps is unknown to me.
- Q: I have a 3 bedroom / 1 bath home. It is just 2 of us in the house. Also, I've heard that there is way to plug your generator into any wall outlet and it will charge your whole house. Any truth to this?
- Plugging a generator into an ordinary wall outlet limits you 15-20 amps of single phase power, or less than 2000-2500w. And it would only energize one leg, or about half the circuits in your house. You'd also want to throw your main breakers to prevent you from backfeeding the neighborhood and/or electrocuting a lineman. Overall, it's not a safe or efficient way to connect a generator. You want a generator plugin that will safely allow more power to fed into your house along with a transfer switch that will properly isolate your house from the grid whenever you want to connect a generator. As for sizing, you need to figure out what you really need vs. what you have, and for how long. For most storm-related outages, you can probably get by with a relatively small amount of power (refrigerator, a few lights, etc) for the few hours or at most 1-2 days that power will likely be out. If you want to cover longer outages or you have higher level of necessities, then you'll need a larger generator. Also, you need to worry about a fuel supply especially if you're planning for a long outage. Fuel transportation and storage can both be problematic, although the problems vary by fuel type (gasoline, diesel, natural gas or propane).
- Q: Can someone please tell me what is the piston ring cap is for the 186FA Diesel Engine 10hp, fitted into the powermate PM6100DS / 6KW Generator.
- Just about all the rings you purchase new today come pre-gapped to the correct tolerance, just like spark plugs. Way in the past, of course back then it was necessary to check the gap. With such a small engine 1/16 is plenty.
- Q: Hello im going to be a mechanic and i will have a 1998 turbo diesel H1 Hummer. Now I wanted to know since the hummer is not like a bus or a really heavy Diesel equipment that i can work on it myself like a regular car or do i have to have to be a diesel mechanic to even work on it?
- Diesel engines are very similar to gasoline engines. If you have the technical knowledge to work on gasoline engines then the same principles applies to diesel engines as well. I know this is true because I took the course for auto/diesel automotive technician certification. I rebuilt them both along with carburetors, transmissions, starters, alternators, and generators. The only difference I can recall are that the diesel engines required more or less air than the gasoline engines. Of course diesel fuels burns much slower than gasoline. Therefore diesel engines might have additional mechanisms to produce or reduce the quantity of air. That is all.
- Q: I want to buy a portable generator for power-outages and need some advice on which to buy. I want to run: at least one refrigerator possibly a stand-alone freezerbasic lightinga few outlets a sum-pump. I also need to provide power to my heat in the winter Our heat is natural gas but it needs to be lit with the pilot light and I guess the thermostats need power. Preferrably diesel so we can store fuel safer. How many volts and watts do I need, what price range should I look for, and how many gallons of fuel would I need to be prepared for a good 2 days without power? Thanks- best answer gets the 10!
- A 5000 watt generator will normally supply most of what you need, a 3500 will give a little more trouble with overloads, but will be quieter wihen not loaded. That Yamaha is a nice generator, if your the type that drives a MB S-Class, if you drive a Ford, you may want to be looking at a $700 Generac brand generator, fuel consumption will vary with load, but running at near capacity will burn a tank (5 gallons) of fuel in 8 hours, the higher the consumption of a generator he bigger the tank they put on. May want to check to see if Fridge and freezer are on opposite legs of your 240V service. FYI: Many electrical panel companies now make bolt in transfer switches to make any circuit in your house available to a generator rather than a gentran that just allows a few circuits