JET Self-priming jet pump
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
- Q: What are the conditions for the series and parallel connection of the pumps?
- 1, pump series, the two pumps must start and stop at the same time in order to normal operation.2 when the pump is connected in parallel, the two pumps must be equipped with check valve at the same time to operate normally.3, of course, in the election of the pump, should meet the requirements of upstairs said.
- Q: I was wonder if there is a water pump in the out drive, my boat is overheating we are think it could have something to do with the water pump
- The water pump is located in the outdrive. You should see a screen area on the lower end where the pump is loicated. I would guess the impeller needs to be replaced. You should stop running the engine 'till it is fixed.
- Q: I have a submersible pump outdoors for the water to my house. Indoors is a holding tank and pressure gauge. It seems the pressure gauge keeps slowly declining down to 20. Then when the toilet is flushed, the gauge kicks on and climbs to 50. Then left alone for a while the gauge again declines to 20. Do I have a leak somewhere? If so , where? Does the ballast inside the holding tank need to be pressurized? If so, how where? I seem to remember years ago, my husband did something with a bicycle tire air pump. Makes sense? Thanks
- I assume you are saying that the pressure drops to 20 when no water is being drawn by any faucets, since that will naturally happen if water is drawn. Four things I would check - first look for leaky toilet float valves - the tank level will drop, and the valve will open periodically to refill the tank if the seal is bad on the float valve. Secondly, make sure you have a check valve installed on the supply line into the pressure tank to prevent water from flowing back down into the well. Third, you may need more air in the tank - I would put enough air in so that the off/on cycle was 60 seconds when one faucet was fully open drawing water. This would not be the cause of leakage, but it could increase the frequency of the 50 to 20 psi cycle. Fourth, I'd adjust the low pressure turn-on point up to over 30 vs. the 20 it is set for now - 20 is probably annoyingly low. Go for a gap of 20 psi from low to high - eg. 30 - 50 psi.
- Q: What is the function of a submersible pump?
- Submersible pump motor and pump is directly connected with the water pump body into the water to work, it is suitable for the extraction of groundwater from wells, can also be used in rivers, reservoirs, canals and other water projects: mainly used for irrigation and plateau in the drinking water, but also for the city, factories, railways, mining and construction site the use of water supply and drainage.Characteristics of submersible pumps for well1 、 motor, water pump, submerged operation, safe and reliable.2, the well pipe and pump water pipe without special requirements (i.e.: steel tube wells, tube wells, Doi ash can be used).3, installation, use and maintenance of convenient, simple, small footprint, do not need to build pumping stations.The structure is simple, and the raw materials are saved.4, submersible pump conditions are appropriate, properly managed, and has a direct relationship with the service life.
- Q: vw tells me the pump is defective, bad water circulation. i noticed the fans did not turn on when it began to overheat. is that irrelevant with the pump being defective? i even drop the car cold(i started the engine and drove) within 10mins it began to overheat, but the fans did not turn on. is it just the pump? the fan switch is new, no fuses are blown. the radiator and fans are less than 2 yrs old. 2000 jetta
- take the car to another mechanic as it sounds like the VW dealership doesn't know what there talking about.
- Q: I live in a residential/country area, and I have a well pump down cellar. I notice that, even if I am not using any water, nothing is running (toilet, etc) it tends to cycle on and off every hour or so. The pressure is always good, so that's not an issue. I am just wondering....is it normal for it to do this?
- How long does it pump when it turns on? This sounds like short cycling; you might have a leak somewhere in the system.
- Q: Submersible pump coupling, what does this coupling mean?
- Coupled with: "two people together in the cultivated land" means, in Chinese, that is, even things linked together meaningCoupling, as the name suggests, means the connection of the pump and the pipe.Submersible pump, used coupling or coupler, because the pipeline extends into the water, the water will not see, through the coupling, pump automatic clamping to the pipe end, simple and quick.
- Q: i'm changing the tyming belt the vehicle has done 120,000 km should i replace water pump as well
- Water pumps get changed when they start leaking or the impeller breaks loose. Not normally changed in a preventive maintenance program.
- Q: We came home one day to find our bathroom floor soaked, and we had no water at all.we later found out that it was the washing machine hose leaking.Our friend primed the pump but isent an expert..we fixed that problem with a new hose.A few weeks after, we started to notice that when you are in the shower, the water would shut off for a minute and come back on for a minute, so on so on, perfectly timed., and this got worse and worse, yesterday it would be on for like 20 secconds and off for 3 minutes... last night the water was working good but today we woke up with no water.The water taps in the house hardly do it at all. I also noticed that when we are running water the water pump goes crazy fast, i can hear it because its a mobile home.
- I'm guessing that you have a well. The others had some good points and I would just like to add that I had a similar problem with my pump. Turned out that the tank had to much air in it and was fooling the pressure switch.
- Q: I'm looking to buy a used 2001 Protege. The car is nearing 75000mi, but the owner has not changed the timing belt or the water pump. I found out that it is recommended to change the timing belt at 60000mi, but couldn't find anything on the water pump. Realistically, when would I need to replace these, and any idea how much it would cost?Thanks!
- That could have either the 1.6 liter or 2.0 liter engine. My information shows that if you have the 1.6 liter, at least you don't have to worry about bending valves against pistons if the belt breaks -- you'll just be stuck out on the road until you can get it towed and fixed. Not so with the 2.0 which is an interference engine. So if you DO have the 2.0, pay attention -- you don't want an expensive breakdown! You're on borrowed time at 75K. For both engines, Mazda recommends that you replace the timing belt every 60K miles. Gates (a major replacement supplier) seems to think these belts will go 105K. Since it's a factory belt, stick with 60K. As for the water pump, it's often one of those while you're already in there sort of things when you're doing a timing belt. 60K makes it a tougher call, especially with the better quality of water pump bearings and seals. If your interval were 80K ~ 100K as is true on some cars, I'd say go for it without blinking. As cheap as it'll be (it's really just the price of the pump), and it was my set of wheels, I'd do it anyway, even at 60K, if it needed to be pulled to do the belt.
Send your message to us
JET Self-priming jet pump
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords