Production Introduction:
JET series pumps have the advtanges and characteristic of self-priming pumps and centrifugal pumps. Water jet elements realize self-priming function.Pumps by the optimized design, have the advantages of bigger suction, high head, smooth operation, and reliable performance, which is the ideal tool for agriculture, and household, etc

Application:
This series pump is a new type of ideal economical household pump, and widely used in pumping water from well, increasing water pressure, garden irrigation, water supply for vegetable green houses, industrial mining enterprises and aquatic breeding fields etc.

Work Conditions:
The pump can work properly and continuously under following op¬erational conditions:
1.Medium is not corrosive. Sand contents should be max.0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40℃and PH should be6.5-8.5.
3.Power frequency should be 50Hz,single phase voltage 220V, and voltage fluctuation should be 0.9-1.1 times than the rated.


Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
The elevator is mainly used by the power grid through the rectifier, filter, inverter and other transmission to the motor. The motor in high speed when the brake suddenly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power, the reverse voltage and torque original electric state torque instead, and the motor with brake strong torque, forcing the rotor to stop fast but usually AC-DC-AC converter is the main power AC/DC rectifier circuit is irreversible and therefore cannot go back to the grid, energy will be accumulated in the filter capacitor, produce pump voltage, this phenomenon of pump voltage converter has great destructive power.
Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
The purpose of the steam separator is to separate the gas from the liquidWater ring type vacuum pump, water, compressed gas is discharged through the exhaust port, if not it is soda water separator is discharged, can not be separated, for the recovery of gas discharged industry is obviously impossible.Soda separator is available, the key is to see the working conditions
Q: What are the causes of pump shock?
3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output
Q: Brief description of centrifugal pump on / off operation
Two, centrifugal pump start(1) the pump entrance valve fully open, start motor, outlet valve fully closed, fully check operation of pump.(2) when the pump outlet pressure is higher than the operation pressure, the outlet valve is gradually opened to control the flow and pressure of the pump.(3) check whether the motor current is within the rated value, such as the pump in the rated flow operation, and the motor overload should stop the pump inspection.
Q: Operating procedures for measuring pumps
Pressurization(1) for the discharge pressure below 2.0MPa, then the pump stroke length should gradually increase, each increase of 20%, to maintain 15 minutes.(2) for the discharge pressure greater than 2.0MPa, you need a special pressure, to ensure that the pump discharge pressure gradually increased, each time for the final row pressure of 20%.(3) when the pressure is not increased, the stroke of the pump is gradually increased by 20% strokes per time.Note (1) when pressure is applied, the pressure gauge should be observed at the side of the loading side (slow motion)(2) check ammeter, forbid overload
Q: What is the difference between centrifugal pump and positive displacement pump?
Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;
Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
Generally speaking, for the fixed size, not limited equipment, the pressure can be selected lower, walking machinery heavy equipment pressure should be selected higher.If the load is selected, the working pressure is as follows:Load <5kN, working pressure <0.8~1MPa;Load 5~10kN, working pressure 1.5~2MPa;Load 10~20kN, working pressure 2.5~3MPa;Load 20~30kN, working pressure 3~4MPa;Load 30~50kN, working pressure 4~5MPa;Load 50kN, working pressure =5MPa;For example, the system work pressure of various machines is as follows:Grinder 0.8~2MPaModular machine tool 3~5MPaLongmen planer 2~8MPaBroaching machine 8~10MPa agricultural machinery, small construction machinery, construction machinery, hydraulic drilling machine 10~18MPa hydraulic machine, large and medium-sized excavators, heavy machinery, lifting transportation machinery 20~32MPa.
Q: What is an industrial water pump?
The pump has the different uses, conveying different liquid medium, different flow rate, different lift range, therefore, its structure of course is not the same, the material is different, in general, can be divided into:1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
Q: Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q: What are the failures and causes of the replacement of the fuel pump assembly?
Failure cause:1) the gasoline pump is too thick with the gasket at the junction of the axle box.2) pump film rupture or pump film and pump shell combination of sealing is not strict.3) the oil inlet valve is stuck or sealed badly.4) severe wear of the rocker arm, reducing the pump film stroke.5) the pipeline from the gasoline tank to the gasoline pump is not smooth, or the pump film spring passes.