Cummins Diesel Generator 500KW/625KVA C38
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 300 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
ENGINE DATA | |||||||
Manufacturer: | Chongqing Cummins Engine | ||||||
Model: | Original Cummins KTAA19-G6A, 4-cycle | ||||||
Air Intake System: | Turbo, Water / Air Cooling | ||||||
Fuel System: | Fuel Pump, EFC | ||||||
Cylinder Arrangement: | 6 in line | ||||||
Displacement: | 18.9L | ||||||
Bore and Stroke: | 159X159(mm) | ||||||
Compression Ratio: | 13:1 | ||||||
Max. Standby Power at Rated RPM: | 610KW/830HP | ||||||
Governor Type: | Electronic | ||||||
Exhaust System | |||||||
Exhaust Gas Flow: | 2054L/s | ||||||
Exhaust Temperature: | 584℃ | ||||||
Max Back Pressure: | 10kPa | ||||||
Air Intake System | |||||||
Max Intake Restriction: | 6.23kPa | ||||||
Burning Capacity: | 750L/s | ||||||
Fuel System | |||||||
100%(Prime Power) Load Consumption: | 206 g/Kw.h | ||||||
75%(Prime Power) Load Consumption: | 205 g/Kw.h | ||||||
50%(Prime Power) Load Consumption: | 206 g/Kw.h | ||||||
Oil System | |||||||
Total Oil Capacity: | 50L | ||||||
Oil Pressure at Rated RPM: | 345-483kPa | ||||||
Cooling System | |||||||
Total Coolant Capacity: | 116.5L | ||||||
Thermostat: | 82-93℃ | ||||||
Max Water Temperature: | 104℃ | ||||||
ALTERNATOR DATA | |||||||
Manufacturer: | Original STAMFORD ,Marathon,MECC,Kaijieli | ||||||
Frequency and Speed: | 50Hz/1500rpm | ||||||
Altitude: | ≤1000m | ||||||
Connecting Type: | 3 Phase and 4 Wires, “Y” Type Connecting | ||||||
Power Factor: | 0.8 | ||||||
Protection Grade: | IP23 | ||||||
Exciter Type: | Brushless, Self-Exciting, with AVR | ||||||
Insulation Class, Temperature Rise: | H/H | ||||||
GENERATING SET DATA | |||||||
Voltage Regulation, Stead State: | ≤±1% | ||||||
Volts Warp(Sudden Reduce): | ≤+25% | ||||||
Volts Warp(Sudden Increase): | ≤-20% | ||||||
Frequency Regulation, Stead State: | ≤5% | ||||||
Frequency Warp(Sudden Reduce): | ≤+12% | ||||||
Frequency Warp(Sudden Increase): | ≤-10% | ||||||
Frequency Recovery Time: | ≤5S | ||||||
Open Type Size: | 3700(mm)X1570(mm)X2080(mm) | ||||||
Open Type Weight: | 4820kg | ||||||
Control System: | Original Uk deep sea auto controller | ||||||
Standards: | ISO9001, ISO14001, European CE |
- Q:I know they are more expensive.
- Yes. But they also burn much hotter in the SOFC.
- Q:I have an idea, if a steam locomotive's boiler was heated by a metal heater instead of a fire, how much less maintance would be needed as it does not produce any ash or soot because it has no fire.
- And WHAT pray tell is going to heat your metal heater?
- Q:I am interested in what are the inherient differences and what are the different sets used for?
- if the energy is forced through a resistance and back to the generator it is dcif the electrons move back and forth it is alternating current
- Q:i can not figure out that why the hiring department selected someone without any interview!!! and one thing i would like to let you know that,my supervisor rejected my RFI at first without giving a look on it giving the reason that lack of three years experience, even having around ten years experience. that means the hiring has made through favoritism or through recommendation.but i am a fool working in CSA for these 22 months hoping to get my professional job,first of all the CSA cheated me while recruiting from India, telling me that i am coming here as a Utility technician(diesel generator mech), but gave me the position Supply Associate, promising to give my professional position within three months,but i got the position Mechanic Associate after sixteen months, but the work is water washing (in Wash Rack). anyhow please let me get the proper person's contacts. so that i may not loose my precious life time and skills like this.looking forward to hear from you soon
- I work for CSA as well, first off are you western or TCN? If you were offered a specific position and didn't get it you should be talking with HR. Or get a Kuwaiti lawyer the company is in violation of labor laws. CSA lately has been doing some very unethical things and are going to get caught.
- Q:1. are backup generators constantly running, so when the lights go out to the people inside it seems like they have not?2. what do they run off?
- Back up generators are kept as stand bye.In hospitals and other important places they take start immediately when voltage drops in the main. They Run with petrol or diesel oil or other fuels/
- Q:I am currently a diesel mechanic in the Army. I know a lot about bothe gas and Diesel engines in cars trucks and generators. My contract is almost up and I m trying to transition back into the civilian world. I was just wondering if someone could help me out with any major differences between a 6.7 liter Diesel engine and the Diesel engines in heavy diesel trucks
- They are bigger.
- Q:How long can I run a Diesel Power Generator before I have to stop it to give it a rest?Also, how many years can I expect a Cummins Diesel Generator to run if maintained properly?One more thing. In the spec sheet of the generator I'm looking at, it states 161 gsm/hp-hr. Is that 161 Grams per Horse Power per hour?So what does that meanHow many liters per hour does that translate too.Thanks for your answers.Greetings from Iran
- The engine can run indefinitely without needing to stop for a rest provided it is properly maintained and cooled. You should change the oil and filters after every 200 hours operating time. Properly maintained you should expect at least 25-30 years operating time from the engine. Neglected and it could need replacing in less than 10. Not sure what 161 gsm/hp-hr means. Unlikely to be grams, but gallons per horsepower hour would be extremely high. Need to look further into it
- Q:I recently seperated the generator from the engine and replaced the rear main oil seal on the engine the electric generator was only moved back about 16-18 inches to access rear main seal. job went well with no problems after completeing job I turned down rpms to about 1000 rpm It was put back in service They use it to power up refer containers from the harbor. the next day I check it and they had turned up rpms to ??? as fast as it would run and 12 refer units running off it oh it's 480 volt well it ran for a week non stop and broke down and of corse it was my fault all i did was unbolt drive plate on front of rotor from flywheel of engine .est to repair is 6,000 could this be my fault after it ran for a week or caused from hi rpms and heat related possibley
- A little more information would be helpful as to the size and model of generator. Is it possible the repair shop could give you more detailed explanation as to exactly what they believe happened? Is this a single bearing or two bearing generator? If it has only one bearing and the shaft is supported by the engine flywheel on the engine end, then the postion and shimming of the engine and generator may be critical to keep the rotor centered between the stator poles. These clearances are very small and they could have been rubbing if not aligned. On small single bearing types, the housings are made to fit together in perfect alignment, and can not be misaligned to avoid this problem. On larger units, this matched housing arrangement may not be possible. A generator with a bearing at each end of it's shaft is less likely to have this problem of rotor alingment, It would have a problem with coupling or bearing failures if not properly aligned with the engine. This link may help explain. cumminsgeneratortechnologies.
- Q:Having a basic background in electric and family moving into a remote prefab home with no electric, water, or gas, I decided to help. House and work shed electric requirements are simple, totaling a possible 5kwh at a given time to the shed, and 7kwh to the home. Obviously the home will have constant electric requirements (fridge, fans, etc). I cannot imagine it is economical nor efficient to run a diesel generator 24/7 for energy production as needed. Here are my questions:1. Should I use a stand-alone or emergency backup generator.2. Should I go with the conventional wisdom of choosing a generator that operates at 80% capacity for 1005 of my needs. IE: I need exactly 12kw maximum, so a ~14kwh generator.3. Solar panels have storage batteries. Can I use 12v or 18v, or an industry specific battery to only operate the generator for several hours a day for storgae of power? I know this is incredibly inefficient, any alternatives?Any help is greatly appreciated. Just need to be pointed in the right direction.
- when you are using your generator, if you have out side power turn it off. look for farms some of them have PTO generators they hook up to a tractor.
- Q:how exactly to fossil fuel power plants work?
- the short answer is they use the fuel to heat water and create steam and use the steam in a turbine to create electricity
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Cummins Diesel Generator 500KW/625KVA C38
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 300 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords