Cummins Diesel Generator 500KW/625KVA C35
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 300 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
ENGINE DATA | |||||||
Manufacturer: | Chongqing Cummins Engine | ||||||
Model: | Original Cummins KTAA19-G6A, 4-cycle | ||||||
Air Intake System: | Turbo, Water / Air Cooling | ||||||
Fuel System: | Fuel Pump, EFC | ||||||
Cylinder Arrangement: | 6 in line | ||||||
Displacement: | 18.9L | ||||||
Bore and Stroke: | 159X159(mm) | ||||||
Compression Ratio: | 13:1 | ||||||
Max. Standby Power at Rated RPM: | 610KW/830HP | ||||||
Governor Type: | Electronic | ||||||
Exhaust System | |||||||
Exhaust Gas Flow: | 2054L/s | ||||||
Exhaust Temperature: | 584℃ | ||||||
Max Back Pressure: | 10kPa | ||||||
Air Intake System | |||||||
Max Intake Restriction: | 6.23kPa | ||||||
Burning Capacity: | 750L/s | ||||||
Fuel System | |||||||
100%(Prime Power) Load Consumption: | 206 g/Kw.h | ||||||
75%(Prime Power) Load Consumption: | 205 g/Kw.h | ||||||
50%(Prime Power) Load Consumption: | 206 g/Kw.h | ||||||
Oil System | |||||||
Total Oil Capacity: | 50L | ||||||
Oil Pressure at Rated RPM: | 345-483kPa | ||||||
Cooling System | |||||||
Total Coolant Capacity: | 116.5L | ||||||
Thermostat: | 82-93℃ | ||||||
Max Water Temperature: | 104℃ | ||||||
ALTERNATOR DATA | |||||||
Manufacturer: | Original STAMFORD ,Marathon,MECC,Kaijieli | ||||||
Frequency and Speed: | 50Hz/1500rpm | ||||||
Altitude: | ≤1000m | ||||||
Connecting Type: | 3 Phase and 4 Wires, “Y” Type Connecting | ||||||
Power Factor: | 0.8 | ||||||
Protection Grade: | IP23 | ||||||
Exciter Type: | Brushless, Self-Exciting, with AVR | ||||||
Insulation Class, Temperature Rise: | H/H | ||||||
GENERATING SET DATA | |||||||
Voltage Regulation, Stead State: | ≤±1% | ||||||
Volts Warp(Sudden Reduce): | ≤+25% | ||||||
Volts Warp(Sudden Increase): | ≤-20% | ||||||
Frequency Regulation, Stead State: | ≤5% | ||||||
Frequency Warp(Sudden Reduce): | ≤+12% | ||||||
Frequency Warp(Sudden Increase): | ≤-10% | ||||||
Frequency Recovery Time: | ≤5S | ||||||
Open Type Size: | 3700(mm)X1570(mm)X2080(mm) | ||||||
Open Type Weight: | 4820kg | ||||||
Control System: | Original Uk deep sea auto controller | ||||||
Standards: | ISO9001, ISO14001, European CE |
- Q: diesel generator
- I'd start with the fuel flow rate, its heating value, an assumed efficiency of a diesel motor and an assumed efficiency of a generator. The diesel motor burns fuel, drives a generator to produce electrical power which is then used to drive electric motors at the wheels.
- Q: A. Chernobyl, UkraineB. Middletown, PennsylvaniaC. Ottawa, Canada
- Date and Time: The Chernobyl nuclear accident occurred on Saturday, April 26, 1986, at 1:23:58 a.m. local time. Location: The V.I. Lenin Memorial Chernobyl Nuclear Power Station was located in Ukraine, near the town of Pripyat, which had been built to house power station employees and their families. The power station was in a wooded, marshy area near the Ukraine-Belarus border, approximately 18 kilometers northwest of the city of Chernobyl and 100 km north of Kiev, the capital of Ukraine. The Accident: On April 26, 1986, the operating crew planned to test whether the Reactor No. 4 turbines could produce enough energy to keep the coolant pumps running until the emergency diesel generator was activated in case of an external power loss. During the test, power surged unexpectedly, causing an explosion and driving temperatures in the reactor to more than 2,000 degrees Celsius—melting the fuel rods, igniting the reactor’s graphite covering, and releasing a cloud of radiation into the atmosphere. Causes: The precise causes of the accident are still uncertain, but it is generally believed that the series of incidents that led to the explosion, fire and nuclear meltdown at Chernobyl was caused by a combination of reactor design flaws and operator error. Number of Deaths: By mid-2005, fewer than 60 deaths could be linked directly to Chernobyl—mostly workers who were exposed to massive radiation during the accident or children who developed thyroid cancer. Estimates of the eventual death toll from Chernobyl vary widely. A 2005 report by the Chernobyl Forum—eight U.N. organizations—estimated the accident eventually would cause about 4,000 deaths. Greenpeace places the figure at 93,000 deaths, based on information from the Belarus National Academy of Sciences.
- Q: A new facility is having a problem with getting power supply, is it safe to run the entire facility (including AC/Ref systems) using a diesel generator? is the power quality guaranteed (considering good quality generator) since that suppliers of AC/Ref systems claimed that this facility would lose the warranty in case of using a generator. Thanks in advance.
- I've done service work in areas after a hurricane, and I've seen a lot of units run off of generators. There's nothing wrong with it. Those systems are fairly hardy. But if the manufacturer says your warranty is at stake, you have to decide how much that warranty is worth to you.
- Q: im 15 me and some people are doing to build a tree house, i want unique ideas were probably going to buy a generator and its going to have an area of 176 square feet, and how much do generators go for
- Hey, firstly this is a very broad question and I'm not quite sure where to start but here goes. There are several different types of generators, petrol are the cheapest (you could get a cheap one for $500-800) this is probably all you would require for a tree house. Diesel generators are more expensive but they are more reliable and diesel fuel does not deteriorate over time as petrol does. (I know this is too much information) For a 15 year old I would suggest: Plenty of couches, chairs beanbags etc. A easy way to get into the tree house, stairs around the trunk for example. A swing down from the tree house. If you have a pool or a trampoline you get organize so you could jump from a low platform.
- Q: I need a means of driving a 3 horsepower induction motor re-purposed as an induction generator which would coincide with specific cost-effective parameters. I ran the numbers in an excel spreadsheet and realized that the amount of gasoline or diesel required to run an engine appropriate for a 3 horsepower generator consumes more fuel per hour than is economical when the electricity is sold back on the grid. Over a month period, here's what I calculated:Run time in Hrs: 300.00 (10hrs a day, 30 days)Gallons per hour: .30 (1/3rd gallon per hour avg. consumption for 5hp engine)AVG output KW: 2.00 (3 horsepower generator)Fuel in gallons: 90.00 Price of fuel $/gal: 3.50Kilowatt-Hrs: 600.00Energy Cost: .08Net Profit: -270.00I've considered using a pressure cooker, wood pellet stove, and compressor pump as steam engine for an economical way to produce long-term torque, but am not sure how to modify the pump to operate as a steam engine. Anyone have any ideas? Thanks
- You are up against economy of scale. The power company produces millions of kW-hours, so they can sell it to you much cheaper than you can possibly generate it. And with a lot less pollution. Your only chance is to use solar cells or a wind turbine, but even there, the payoff period for the capital expense is 20 years or more, unless you have very favorable conditions. And the equipment used to synchronize with the power line and generate your power must be approved by the power company. I doubt they would approve your home made generator. In fact even with approval, it takes an expert to get it working correctly.
- Q: because generating electricity is not very efficient, coal being imported from bolivia etcDoes it matter how far the stations are apart?btw dieselectric means the locomotive isn't directly diesel-driven, but runs on electricity generated by a diesel-generator inside the locomotive
- The advantages of dieselelectric outweigh steam, mostly due to the high maintenance required on coal-fired steam engines. Another large factor is the ability of electrical generator to drive the traction motors required to overcome the inertia of the enormous mass of the freight when the train is starting up. Efficiency is not simply the mechanical efficiency of the system, but the ability to maintain the system and adapt it to various tasks.
- Q: Design the logic circuit for starting an emergency diesel generator. For the generator to start, the generator must be disconnected from the bus, there must be sufficient start air pressure, and the fuel tank must indicate there is oil. When these conditions are met, then the diesel may be started. Presume there are senors to determine these values.
- This is just an and gate function. When the outputs of all the sensors are true and a start command is present, the output of the gate will go high to allow the engine to start.
- Q: I am designing the system to produce electricity for a computer room with 40 PC and 40 LCD screens. The needed power is about 15 KW (20 hp). My system consists of a compressor, a compressed air tank, a turbocharger and a mini gas turbine. I will talk a little bit about the operation: the air is released from the tank and driven by ducting system to turbocharger, at which the air flow is through turbocharger and run turbine to produce electricity. I have searched in internet many times about the turbine but still have no fit one. Can anybody suggest me one? And the turbocharger too if you don't mind. I really need all the details about both of them for calculations.
- 15kW gas turbine not as efficient, much noisier, more expensive, gearbox problems GO DIESEL
- Q: I am looking for a portable propane generator primarily as a home backup. I have a couple models in mind but have no clue about the quality. they seem to have good reviews, but wanted to ask in here anyways. i'm looking at the Sportsman GEN7000LP or Powerland PD3G8500E Tri-Fuel. anyone have experience with either of these? or can recommend a similarly capable brand/model?
- who manufactures sportsman 7000 generators
- Q: How much is the waste of the power that may be lost in the combination of two engine and where I can find the diagram that shows the relation between rpm and HP in the combined two diesel engine.this two engine combined with a clutch that synchronize two engine for two input in gears and single output.
- It's best to connect them at the crank so that they can be timed to fire in a manner that your getting the most amount of power you can. This has been done in applications as small as a .12cc engine all the way up to huge engines that power large ships. The most common place I used to see it is with gas engines for tractor pull. The engines do sync up and will run together when you pair them up thru a clutch
Send your message to us
Cummins Diesel Generator 500KW/625KVA C35
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 300 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords