• AC Solar Submersible Water Pump System System 1
AC Solar Submersible Water Pump System

AC Solar Submersible Water Pump System

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
300000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Products

Solartech China Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.


In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, Solartech Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


Solartech Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

Technical Features

Solar Water Pump is a pumping device powered by solar energy, consists of a solar pumping inverter and a deeo well pump, mainly used for agriculture irrigation, desert control, pasture animal husbandry, city waterscape, seawater desalination, living water supply and so on.

Use solar energy, need no connection to grid.         Automatically operation, maintenance free.
Easy to install and move, high universality.              Clean and green, high economic benefits.

Solartech solar pump kit also named solar water pumps, solar pond pump, solar borehole pump, solar funtain pumps, solar powered water pump, solar irrigation pump, solar deep well pump, and solar submersible pump.

Product Specifications

Model

Pump Spec.

Adapting Water Head

Daily Water Supply

Outlet internal Dia.

Adapting well Dia.

Recommended Open Circuit Voltage

Recommended MPP Voltage

SPA4370010

3PH 220V 50Hz

47-32m

1-10 m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4370020

3PH 220V 50Hz

29-20m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550010

3PH 220V 50Hz

70-48m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550020

3PH 220V 50Hz

40-28m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550040

3PH 220V 50Hz

23-15m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA4750010

3PH 220V 50Hz

81-56m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4750020

3PH 220V 50Hz

60-41m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4750040

3PH 220V 50Hz

29-19m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA4750060

3PH 220V 50Hz

15-8m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA4750100

3PH 220V 50Hz

7-6m

60-100m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K1010

3PH 220V 50Hz

93-63m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K1020

3PH 220V 50Hz

79-54m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K1040

3PH 220V 50Hz

43-27m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K1060

3PH 220V 50Hz

23-12m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K1100

3PH 220V 50Hz

12-8m

60-100m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5010

3PH 220V 50Hz

128-87m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K5020

3PH 220V 50Hz

99-68m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K5040

3PH 220V 50Hz

51-33m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K5041

3PH 220V 50Hz

60-39m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K5060

3PH 220V 50Hz

29-15m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5130

3PH 220V 50Hz

10-7m

100-130m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5100

3PH 220V 50Hz

20-12m

60-100m3

65mm

2"1/2

150 mm

350-450VDC

280-350VDC

SPA42K2010

3PH 380V 50Hz

163-111m

1-10m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA42K2020

3PH 380V 50Hz

145-90m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA42K2040

3PH 380V 50Hz

79-51m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA42K2060

3PH 380V 50Hz

50-27m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA42K2130

3PH 380V 50Hz

17-12m

100-130m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA42K2100

3PH 380V 50Hz

30-18m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA43K0020

3PH 380V 50Hz

187-114m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA43K0040

3PH 380V 50Hz

105-65m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA43K0060

3PH 380V 50Hz

67-37m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA43K0061

3PH 380V 50Hz

79-43m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA63K0100

3PH 380V 50Hz

40-24m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA63K0130

3PH 380V 50Hz

23-16m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA63K0250

3PH 380V 50Hz

18-9m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA44K0020

3PH 380V 50Hz

225-149m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA44K0040

3PH 380V 50Hz

145-89m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA44K0060

3PH 380V 50Hz

94-55m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA44K0100

3PH 380V 50Hz

50-32m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA64K0100

3PH 380V 50Hz

56-36m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0130

3PH 380V 50Hz

30-22m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0131

3PH 380V 50Hz

37-27m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0250

3PH 380V 50Hz

26-13m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB64K0500

3PH 380V 51Hz

17-6m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA45K5040

3PH 380V 50Hz

172-111m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA45K5060

3PH 380V 50Hz

113-62m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA45K5100

3PH 380V 50Hz

67-44m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA65K5100

3PH 380V 50Hz

75-48m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA65K5130

3PH 380V 50Hz

53-39m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA65K5250

3PH 380V 50Hz

35-21m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB65K5500

3PH 380V 50Hz

25-10m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA47K5040

3PH 380V 50Hz

237-147m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA47K5060

3PH 380V 50Hz

137-75m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA47K5100

3PH 380V 50Hz

87-57m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA67K5100

3PH 380V 50Hz

114-67m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA67K5130

3PH 380V 50Hz

67-50m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA67K5250

3PH 380V 50Hz

44-25m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA67K5251

3PH 380V 50Hz

52-30 m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB67K5500

3PH 380V 50Hz

33-15m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA69K2100

3PH 380V 50Hz

140-85m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA69K2103

3PH 380V 50Hz

83-60m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA69K2250

3PH 380V 50Hz

62-40m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB69K2500

3PH 380V 50Hz

42-20m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA611K100

3PH 380V 50Hz

159-97m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA611K130

3PH 380V 50Hz

105-77m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA611K250

3PH 380V 50Hz

72-46m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB611K500

3PH 380V 50Hz

50-23m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA613K100

3PH 380V 50Hz

189-115m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA613K130

3PH 380V 50Hz

120-88m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA613K250

3PH 380V 50Hz

81-52m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB613K500

3PH 380V 50Hz

59-27m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA615K100

3PH 380V 50Hz

208-127m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA615K130

3PH 380V 50Hz

135-99m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA615K250

3PH 380V 50Hz

88-58m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB615K500

3PH 380V 50Hz

67-31m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA618K130

3PH 380V 50Hz

143-109m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA618K250

3PH 380V 50Hz

101-63m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB618K500

3PH 380V 50Hz

83-39m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPC822K270

3PH 380V 50Hz

86-70m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC822K330

3PH 380V 50Hz

70-55m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC822K420

3PH 380V 50Hz

55-48m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC822K540

3PH 380V 50Hz

48-36m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC822K700

3PH 380V 50Hz

36-25m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC826K270

3PH 380V 50Hz

105-85m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC826K330

3PH 380V 50Hz

85-65m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC826K420

3PH 380V 50Hz

65-55m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC826K700

3PH 380V 50Hz

44-30m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC830K270

3PH 380V 50Hz

125-105m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC830K330

3PH 380V 50Hz

105-85m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC830K420

3PH 380V 50Hz

85-70m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC830K540

3PH 380V 50Hz

70-52m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC830K700

3PH 380V 50Hz

52-35m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC837K270

3PH 380V 50Hz

150-125m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC837K330

3PH 380V 50Hz

125-100m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC837K420

3PH 380V 50Hz

100-80m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC837K540

3PH 380V 50Hz

80-60m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC837K700

3PH 380V 50Hz

60-40m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC845K270

3PH 380V 50Hz

180-145m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC845K330

3PH 380V 50Hz

145-120m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC845K420

3PH 380V 50Hz

120-98m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC845K540

3PH 380V 50Hz

98-72m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC845K700

3PH 380V 50Hz

72-50m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC855K270

3PH 380V 50Hz

200-170m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC855K330

3PH 380V 50Hz

170-155m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC855K420

3PH 380V 50Hz

155-125m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC855K540

3PH 380V 50Hz

125-95m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC855K700

3PH 380V 50Hz

95-65m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC


Q: I received a call from my daughter who said that the water pump was making a grinding noise. She sent a photo to me showing 0 psi on the gauge. I came home to find it actually working again but after running water straight from the pump I found that it is really rusty. What is this caused from? Our water was nice and clear! We've had freezing conditions here. Still doesn't explain the sudden rust.
Ok there are several possibilities one is that since pressure went to zero you stirred up sediment in the surge tank especially if it is the old style before bladder type also if air got into pipes that will loosen rust but these are minor and will clear with time and use but i would worry what is wrong with pump that goes to zero and makes noise you better check that out or your at risk it wont restart next time
Q: I bought a new water pump for my 89 S10 Blazer with the 4.3 V6. The guy at Autozone wanted to know if I wanted a standard one or the heavy duty. I bought the heavy duty one because it was only $5.00 more. Are they just built stronger or do they actually move more water?
The intense flow in simple terms strikes greater water in line with revolution the a manufacturing facility pump. Heavy accountability must be the comparable because of the fact the hi-flow, whilst the electrical powered pump would not use the fan belt to coach the pump, this is have been given a small electric powered motor to try this. See if there is any distinction between hi-flow heavy accountability, get one in all those.
Q: I've always wondered how a water pump moves water through a pipe. A fan moves air by spinning a propeller-like set of blades, but does a water pump work the same way? Or is there some other kind of mechanism inside the pump that draws water from one place and pushes it to another?
IT CAN BE LIKE A FAN (CENTRIFUGE) OR IT CAN USE SUCTION AND GRAVITY LIKE A WELL PUMP
Q: I've been hearing a noise from my truck that sounds like a fan blade is rubbing against something metal but I could never figure out what it was and my truck seemed to be running fine. I recently replaced my radiator and now my truck is overheating. Was that noise my water pump going bad and now it's shot?
wiggle the fan blades and if they move any it is a bad water pump, they will also leak a little bit under the main shaft of the water pump housing, there is a hole on the bottom and top just for this reason, the metal squealing is the impeller in the water pump, it wont last long now
Q: We have fresh running water..no well... We just want to install it on our playground for the kids to experience a manual water pump. Can it be attached to running water? Do I need a tank? Help! Thank YOU!
With no offense meant at all to answer 1... I grew up without indoor plumbing on a farm. ALSO while this is to be functional it reads as if it's to be a demonstration of the process of lifting water by means of the action of a pump. I suggest certainly that it not strictly be a means for practical use IE: drinking; etc. Obviously you'd need a receptacle that will hold enough water to allow the pump to perform. A 5 gallon paint bucket could suffice perhaps. A platorm to bolt the pump head to, and perhaps some method of keeping it all from spilling over when eager students engage with it. I have never checked with HD or Lowes, but certainly online you'd get an answer rather quickly. Farm/Feed stores most definitely would have functional hand crank/lever, water pumps. Also often sold in RED or GREEN,,,smile. I'll assume you have a custodian/maintenance person/husbands/boyfriends/fathers/mothe... who would be happy to get involved and you could be pumping in less than an hour. The situation obviously can be portable and brought indoors at the end of any day you choose to use it for the purposes you define. Steven Wolf
Q: I have a quot;Rainbow Lifeguard Quiet One 6000external pump that I would like to use on a new chiller for my tank. The pump is rated at a little over 1500 gallons per hour. I'm debating between a couple of chillers, one that has a max flow rate of 1300 gph and another that has a max of 960.I know that you are only supposed to put any valves on the outflow side of the pump and lessening the flow to 1300 from 1500 doesn't seem like it would be that big of a problem, but I was curious it cutting it back to 960 would be hard on the pump in the long run. (I'm leaning towards the bigger chiller as although it may be overkill for my tank, it would let me have a little more water circulation.)
I wouldn't restrict it more than about 10% or so personally. I would ask you to think about this: The rated flow rate on a pump is under perfect operating conditions and is usually a mathmatical model that cannot really be acheived in the real world. Your pump probbaly is several gallons per hours behind that. If the tank is on a stand and the pump on the floor, the head pressure alone may slow it to 1300 or below. Additional tubing, especially hard angles will further reduce the flow. I would suggest you get a flow meter ( you can probably borrow one from a plumber for a day) and test the actual flow rate in your set up. Remember that the chiller will further reduce the flow itself. Odds are good you are closer to the needed 1300 than you think. You can also install a small diverter valve in the line. Basically splitting the output from the pump into two lines. One can carry about 1250 GPH and the other the rest which it just returns to the tank unchilled. Hope that helps MM
Q: How can the pump be stationary?
Rusty, turn with your hands to see the situation, the two bearings filled with lubricating oil.
Q: When the pump is running with frequency conversion, the instantaneous power is greater than the power frequency operation, and the actual flow and lift are less than the power frequency. When running, the efficiency is very low. Why?
Variable frequency pump running normally, its flow and lift is lower than the power frequency operation, that is for sure. The so-called power frequency operation is full speed operation, of course, the head and flow is the highest.Frequency conversion is mainly to save power and reduce the running loss of equipment. The so-called efficiency, but also by the correct selection, the actual pump head and flow as close as possible, the actual working conditions for the best.
Q: How do you remove the water pump from bmw m42 engine?
Follow the instruction manual Drain the water first then remove the timing case release the tension from the belt, unbolt it and remove.
Q: just pulled my well pipe up and installed a new foot valve will i have to fill the pipes back up with water before i can get it to pump
How To Prime A Pump: (Need: Gallon jug of drinking water, a roll of teflon tape, and an adjustable wrench or a pipe wrench.) A. Unplug pump (or cut OFF breaker box at pump, if one). B. Unscrew (counter-clockwise) the largest (3/4) plug on top of pump head. C. Wrap 2-3 flat turns (clockwise only) of teflon tape on threads of plug. D. Pour water into plug hole until full, and quickly start threads of plug by hand. E. Plug in or turn on pump, and finger-tighten plug (air and water will bubble out around threads as you do so) until pump picks up prime. Then wrench-tighten plug when it does. Repeat all steps, if necessary, until you have full water pressure and pump cuts off on its own. Good Luck!

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords