• AC Solar Water Pump System System 1
AC Solar Water Pump System

AC Solar Water Pump System

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
300000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Products

Solartech China Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.


In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, Solartech Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


Solartech Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

Technical Features

Solar Water Pump is a pumping device powered by solar energy, consists of a solar pumping inverter and a deeo well pump, mainly used for agriculture irrigation, desert control, pasture animal husbandry, city waterscape, seawater desalination, living water supply and so on.

Use solar energy, need no connection to grid.         Automatically operation, maintenance free.
Easy to install and move, high universality.              Clean and green, high economic benefits.

Solartech solar pump kit also named solar water pumps, solar pond pump, solar borehole pump, solar funtain pumps, solar powered water pump, solar irrigation pump, solar deep well pump, and solar submersible pump.

Product Specifications

Model

Pump Spec.

Adapting Water Head

Daily Water Supply

Outlet internal Dia.

Adapting well Dia.

Recommended Open Circuit Voltage

Recommended MPP Voltage

SPA4370010

3PH 220V 50Hz

47-32m

1-10 m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4370020

3PH 220V 50Hz

29-20m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550010

3PH 220V 50Hz

70-48m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550020

3PH 220V 50Hz

40-28m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550040

3PH 220V 50Hz

23-15m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA4750010

3PH 220V 50Hz

81-56m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4750020

3PH 220V 50Hz

60-41m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4750040

3PH 220V 50Hz

29-19m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA4750060

3PH 220V 50Hz

15-8m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA4750100

3PH 220V 50Hz

7-6m

60-100m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K1010

3PH 220V 50Hz

93-63m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K1020

3PH 220V 50Hz

79-54m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K1040

3PH 220V 50Hz

43-27m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K1060

3PH 220V 50Hz

23-12m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K1100

3PH 220V 50Hz

12-8m

60-100m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5010

3PH 220V 50Hz

128-87m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K5020

3PH 220V 50Hz

99-68m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K5040

3PH 220V 50Hz

51-33m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K5041

3PH 220V 50Hz

60-39m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K5060

3PH 220V 50Hz

29-15m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5130

3PH 220V 50Hz

10-7m

100-130m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5100

3PH 220V 50Hz

20-12m

60-100m3

65mm

2"1/2

150 mm

350-450VDC

280-350VDC

SPA42K2010

3PH 380V 50Hz

163-111m

1-10m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA42K2020

3PH 380V 50Hz

145-90m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA42K2040

3PH 380V 50Hz

79-51m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA42K2060

3PH 380V 50Hz

50-27m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA42K2130

3PH 380V 50Hz

17-12m

100-130m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA42K2100

3PH 380V 50Hz

30-18m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA43K0020

3PH 380V 50Hz

187-114m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA43K0040

3PH 380V 50Hz

105-65m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA43K0060

3PH 380V 50Hz

67-37m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA43K0061

3PH 380V 50Hz

79-43m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA63K0100

3PH 380V 50Hz

40-24m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA63K0130

3PH 380V 50Hz

23-16m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA63K0250

3PH 380V 50Hz

18-9m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA44K0020

3PH 380V 50Hz

225-149m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA44K0040

3PH 380V 50Hz

145-89m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA44K0060

3PH 380V 50Hz

94-55m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA44K0100

3PH 380V 50Hz

50-32m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA64K0100

3PH 380V 50Hz

56-36m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0130

3PH 380V 50Hz

30-22m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0131

3PH 380V 50Hz

37-27m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0250

3PH 380V 50Hz

26-13m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB64K0500

3PH 380V 51Hz

17-6m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA45K5040

3PH 380V 50Hz

172-111m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA45K5060

3PH 380V 50Hz

113-62m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA45K5100

3PH 380V 50Hz

67-44m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA65K5100

3PH 380V 50Hz

75-48m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA65K5130

3PH 380V 50Hz

53-39m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA65K5250

3PH 380V 50Hz

35-21m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB65K5500

3PH 380V 50Hz

25-10m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA47K5040

3PH 380V 50Hz

237-147m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA47K5060

3PH 380V 50Hz

137-75m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA47K5100

3PH 380V 50Hz

87-57m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA67K5100

3PH 380V 50Hz

114-67m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA67K5130

3PH 380V 50Hz

67-50m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA67K5250

3PH 380V 50Hz

44-25m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA67K5251

3PH 380V 50Hz

52-30 m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB67K5500

3PH 380V 50Hz

33-15m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA69K2100

3PH 380V 50Hz

140-85m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA69K2103

3PH 380V 50Hz

83-60m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA69K2250

3PH 380V 50Hz

62-40m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB69K2500

3PH 380V 50Hz

42-20m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA611K100

3PH 380V 50Hz

159-97m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA611K130

3PH 380V 50Hz

105-77m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA611K250

3PH 380V 50Hz

72-46m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB611K500

3PH 380V 50Hz

50-23m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA613K100

3PH 380V 50Hz

189-115m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA613K130

3PH 380V 50Hz

120-88m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA613K250

3PH 380V 50Hz

81-52m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB613K500

3PH 380V 50Hz

59-27m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA615K100

3PH 380V 50Hz

208-127m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA615K130

3PH 380V 50Hz

135-99m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA615K250

3PH 380V 50Hz

88-58m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB615K500

3PH 380V 50Hz

67-31m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA618K130

3PH 380V 50Hz

143-109m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA618K250

3PH 380V 50Hz

101-63m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB618K500

3PH 380V 50Hz

83-39m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPC822K270

3PH 380V 50Hz

86-70m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC822K330

3PH 380V 50Hz

70-55m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC822K420

3PH 380V 50Hz

55-48m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC822K540

3PH 380V 50Hz

48-36m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC822K700

3PH 380V 50Hz

36-25m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC826K270

3PH 380V 50Hz

105-85m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC826K330

3PH 380V 50Hz

85-65m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC826K420

3PH 380V 50Hz

65-55m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC826K700

3PH 380V 50Hz

44-30m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC830K270

3PH 380V 50Hz

125-105m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC830K330

3PH 380V 50Hz

105-85m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC830K420

3PH 380V 50Hz

85-70m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC830K540

3PH 380V 50Hz

70-52m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC830K700

3PH 380V 50Hz

52-35m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC837K270

3PH 380V 50Hz

150-125m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC837K330

3PH 380V 50Hz

125-100m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC837K420

3PH 380V 50Hz

100-80m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC837K540

3PH 380V 50Hz

80-60m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC837K700

3PH 380V 50Hz

60-40m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC845K270

3PH 380V 50Hz

180-145m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC845K330

3PH 380V 50Hz

145-120m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC845K420

3PH 380V 50Hz

120-98m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC845K540

3PH 380V 50Hz

98-72m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC845K700

3PH 380V 50Hz

72-50m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC855K270

3PH 380V 50Hz

200-170m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC855K330

3PH 380V 50Hz

170-155m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC855K420

3PH 380V 50Hz

155-125m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC855K540

3PH 380V 50Hz

125-95m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC855K700

3PH 380V 50Hz

95-65m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC


Q: My fiance's 2002 Cougar is overheating and we can't seem to diagnose the problem. As soon as she touches the gas pedal, the meter shoots to quot;Hquot;, but when we sit at a red light, it returns to center. I tried googling a few things and I've gotten a few things about the water pump, but I know next to nothing about cars. Where is it so I can look at it and feel dumb about STILL not being able to do anything? =D
Leave the water pump alone! It sounds to me like your gauge is malfunctioning. Every so often an electrical gauge will fail and give strange readings. It could either be the sensor that reads your coolant temp or the gauge body itself. Your car cannot go from overheating to fine while stationary at a red light. Take it to a shop (that specializes in electrical, they're out there) and tell them the temp gauge is acting wacky. If you INSIST to know the location of your water pump...should be on the passenger side of the car mounted to the engine. It's either driven by an accessory belt or the timing belt, I can't remember at the moment. Here's a trick also. Water pumps are designed to leak when they fail. See if you can find coolant spilling out of anywhere a few ounces at a time. Good luck!
Q: My toyota 99 camry stalled and would not start. engine turned over and all lights worked. had the oil changed 3 weeks ago and they told me their was a noise and it might be the water pump. my questions are does this sound like the water pump? Do they usually change the timing belt and is this necessary? is this something that we can do at home? thank-you for any info out their!
camry requires special tools and not easily accesible. timing belt is a '' good idea for a 99
Q: I've got a 1997 Ford Probe, taken it to a couple different places; whenever I drive my vehicle, it tends to want to overheat. I don't drive it to the point where it does though, I know that could cause more damage! I've noticed that when I go out to my car in the morning, there's some coolant on the ground by the front passenger's tire. Before I drive it I fill it with coolant, as to try to keep it from overheating while driving.I've been told that it's the water pump leaking from 2 people but then the last person said there's no leakage. I'm wondering if it might be something else? Maybe a thermostat, a hose, maybe? How would I figure this out???
Power wash the engine bay. THen drive the car over a quicky lube pit and pay the attendant $5 to examine the car from underneath. He should be able to tell. Is this the 3.0 liter engine?? Use only genuine Ford coolant in it! Also, power wash the space between the radiator and the A/C condenser
Q: An engineer is given the job of designing the water system for a tall building. He decides to locate the pumps at ground level and feed the entire building from there. If the top floor of the building is 236 m above ground level, what must the pressure be at pump level?
Adding to Colin's answer, in addition to pgh, you also must add the atmospheric pressure, which is the pressure caused by the air at roughly the Earth's surface, unless whatever vessel the engineering is trying to pump the water into is a vacuum or otherwise not exposed to the air outside. atmospheric pressure: 1 atm = 1.013 x 10^5 Pa
Q: Hello, i have a 1987 volkswagen cabriolet that i purchased earlier this year. So far its been a pain in the butt. Recently i noticed it overheats real quick, but it didnt use to. then i noticed the coolant/antifreeze was being used up like no other! I discovered, after being parked at work, that it was leaking.it leaks basically anything i put in there now!! it leaks from the water pump housing,.,.... at least thats what the internet said it was.. its leaking from the end of the hose that connects to the engine... (the hose that comes from the coolant reservoir.)What do i do? I dont feel any cracks? does this part crack? is it an o-ring or somehting? I am really absolutely NOTHING ABOUT CARS. Please help!!
You say it has been below freezing for a while. *IF* it has been very cold and *IF* your pipes are not below the frost lines in your area, then the pipe could be frozen. That would cause the pump to likely trip out as it would over-work while trying to push water through ice (not easily done!) The good news is if the pipe is frozen, it is most likely frozen near the point where the water goes into or out of the ground. If you have access to 110 power in both of those areas, (or can get it there by some safe means) try this. Take a heating pad (like you use for sore backs/ knees) and wrap it around the pipe right at the point where it transitions into the ground. Tie it in place with string or yarn and turn it on at it's highest setting. After about an hour try turning on the pump. Still trip? Give it another hour. Still trip? Do the other end. Believe me this works surprisingly well, and once you get the water flowing, even just a little bit, the rest will melt quickly. Good Luck. James
Q: I just bought a house a little more then a month ago and just received my first electric bill and it's OUTRAGEOUS!! I have a feeling my electric pump is doing most of my water heating which I found out it is (currently it's on 24 hours a day .. I didn't know). Now, I called a solar company in my area that deals with Hartell pumps, they said if the Hartell pump is working, it should be vibrating .. mines is not .. are they correct? They also said it only works when the sun is out, so by evening, I have to switch on my electric water heater. I'm just checking to see if I'm receiving the correct information before I time my electric water heater .. since every other local solar company I called are unfamiliar with Hartell pumps.
OK, well your question is a bit confusing and I am not sure if it is because you don't understand how your system works. Your hartell pump pumps water. It does not produce heat. Your water heater heats water. It is a backup to your solar panel system. If on the other hand you have a heat pump as a back up source of heat this could be an entirely different matter and you are best at providing a model number which should be stamped on the part. We need to start again. Is your system for solar hot water or for general heating? Is it a system in a cold climate where freezing is an issue. Is it a pump down system or a system that circulates antifreeze in the solar loop. The reason all this is significant is that if you are paying a lot in electricity then something is not working. The first question has to be is it a design problem, a mechanical problem or an operational problem. You may need more hot water storage or more solar panels, you may need to replace parts, or you may simply need to turn the right valves (This would be the case where you have a grounding loop to keep the solar panels from overheating in the summer.)
Q: motor overheats but no leak. water just boils in resorvoir. is it hard to do it on my own?
ummm please make sure you have proper coolant and not just water in your rad
Q: To get at the timing belt on a Toyota 3.4L V6, does the water pump first need to be removed?If so, is there a way to tell how worn a water pump with 85,000 miles is? Like a loose bearing feel, etc?
If you are replacing the timing belt it is recommended you also replace the water pump. They have similar life spans and one has to be removed to replace the other.
Q: We had to have our well pump replaced yesterday, how long before the well settles down, and the water tastes like it used to?The company who replaced the pump told us when changing a pump it disturbs the well, and it would take time for everything to settle back into place. Thank you in advance for any and all suggestions.
Something seems a little fishy here besides the smell of the water. 1) Replacing the pump will do nothing to keep your well from being sucked dry unless the pump was sunk lower in the well. 2) A space is left between the bottom of the pump and the bottom of the well so that you have a place for sediment to settle, anywhere from 10' to 50'. 3) If you sink the pump lower you are placing it in the sediment area and will keep sucking up sediment until its level is drawn down. 4) Water literally flows thru the well and unless your well casing was damaged or the walls below it are collapsing it would be difficult to stir up anything. Apparently what they have done is to lower the pump pipe causing the pump to sit in the available sediment area. If you run the pump enough you will eventually suck the sediment down out of the bottom of the well. However, you will have less of a sump left and you will draw more sediment out of the well from now on. The only permanent solution to your problem was to drill the well deeper. I have recent firsthand experience with this both professionally (customers wells) and personally (my own well). The water will clear up but it may take some time and quite a bit of flow but from now on you will draw more particulates out of your well. Your cheapest and best solution is to invest in a filter to go inline after your pressure tank. They run about $70 plus installation and will need the filters changed between 1 and 6 months depending on how turbid your water is. Good Luck!
Q: I'm using an old Mitsubishi Lancer. Recently I changed my water pump it was leaking.To me it looked like a piece of metal, with a small fan thing (not motorized) How can it fail? There is no mechanics to it, just like a pipe with a fan (or turbine)I also messed with my radiator, I unhooked the main hose to clean out the coolant, since the plug was jammed. Could this have contributed to the failing of my water pump?