• DC/AC Solar Water Submersible Pump Systems System 1
  • DC/AC Solar Water Submersible Pump Systems System 2
  • DC/AC Solar Water Submersible Pump Systems System 3
DC/AC Solar Water Submersible Pump Systems

DC/AC Solar Water Submersible Pump Systems

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
400 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Solar Water Pumping System Introduction

 

1-60 tons/h flow solar water pump for irrigation with IP68 rating

 

1,Solar Cell Array
    The solar array, an aggregation of many solar modules connected in series and in parallel, absorbs sunlight radiation and converts it into electrical energy, providing dynamical power for the whole system.
2,Solar Pumping Inverter
    The pumping inverter controls and adjusts the system operation and converts the DC produced by the solar cell array into AC to drive the pump, and adjusts the output frequency in real-time according to the variation of sunlight intensity to realize the maximum power point tracking (MPPT). Advantages are as follows:
       1). Patented dynamic VI MPPT algorithm ensuring swift response and stable operation
       2). Digital control, automatic operation, data collection and storage for up to 8 years, etc; 98% conversion efficiency, complete protection
      3). The system is free of any energy storage devices. Instead, the system stores water. As a result, reliability is improved dramatically comparing to systems requiring energy storage (battery) and at the same time greatly reducing construction and maintenance costs
3,Pump
    Any three-phase pump is suitable for solar AC pumping system, pump powered by solar cell arrays draws water from the deep wells or rivers and lakes and pours into the storage tank or reservoir, or directly connects the irrigation system, fountain system, etc. According to the actual system demand and installation condition, different types of pumps such as centrifugal pump, axial flow pump, mixed flow pump or deep well pump can be used.

 


Q: What is a water pump coupling device?
Advantages of water pump coupling device:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device, fixed installation, such as water pump failure, maintenance personnel need to unscrew screws, lifting pumps for maintenance, or with other small pumps pumping water perfect maintenance,If the water is dirty, it is difficult for people to get down, when the inspection and repair encountered great difficulties. But it is equipped with GAK submersible sewage pumpAfter the automatic coupling device needs lifting, the person can directly lift the water pump without the need to screw the screw into the waterAfter graduation, down the guide rail, you can realize the sealing of water pump and pipeline, so as to make the pump run normally. Small sewage pumps are freeInstallation, large sewage pumps are generally equipped with automatic coupling device, automatic installation, installation and maintenance is very convenient.
Q: Why should the pump be closed when the centrifugal pump is started?
Therefore to close the outlet valve, the pump during starting output water, the minimum pump power, when the pump reaches the rated speed, slowly open the outlet valve, gradually increase the flow of water, the motor current is gradually increased to the rated current.
Q: Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
Q: What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
When the pump is working, the liquid at the inlet of the impeller, due to a certain vacuum pressure will produce steam, the vaporization of the bubble in liquid particles under the impact of movement, the impeller and other metal surface erosion, thereby damaging the impeller and other metal
Q: What are the starting and stopping procedures for centrifugal pumps?
The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
(1) the pellet dose in the safety standard of the infusion pump refers to the amount of liquid that is transported to the patient in a short period of time(two) pill dose limit is mainly to control the risk of accidental pill dosage. Especially after the mandatory requirements of pipe blockage in the elastic pipe storage liquid limit amount of agglomeration and the limitation of these methods to release pill dose.
Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
Q: What is an industrial water pump?
The pump has the different uses, conveying different liquid medium, different flow rate, different lift range, therefore, its structure of course is not the same, the material is different, in general, can be divided into:1, urban water supply 2, sewage system 3, civil and construction systems 4, agricultural water conservancy system 5, power station system6. Chemical system 7, petroleum industry system 8, mine metallurgy system 9, light industry system 10, ship system
Q: Types and differences of pumps
Depending on the flow of the fluid, they can be subdivided into the following:Classified centrifugal axial flow type mixed flow tubular flow typeThe basic principle of impeller centrifugal force generated by the high-speed rotation of the fluid energy rotary vane extrusion propulsion of the fluid increases the pressure to get the energy mix and energy principle of centrifugal and axial and centrifugalSuch as: central air conditioning centrifugal fan, central air conditioning or cold storage axial flow water pump, mixed flow water pump, domestic air conditioner, indoor fanWorking principle of pump and fanI. the working principle of centrifugal pumps and fansThe centrifugal force generated by the high-speed rotation of the impeller fluid power, namely fluid through the impeller, pressure and kinetic energy can be improved, which can be transported to the height or distance. The impeller is arranged in a spiral shell, when the impeller rotates, the fluid axial inflow, and then turn 90 degrees into the impeller and the radial outflow impeller. Continuous rotation of the impeller inlet in the form of vacuum, so that the fluid continuously by the pump suction and discharge.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords