Operating characteristics:

 

(1) The long-time permissible operating temperature is 70oC;

 

The ambient temperature under installation should not go below 0oC.

 

(2) a. for non-armoured cable and flexible shielded cable, the bending radius should not be less than 6 times the outer diameter;

 

Model

Description

Application

KVV

copper conductor, PVC insulated, PVC sheathed, control cable

Suitable for being laid indoors, in cable trench, pipelines or other specific occasions.

KVVP

copper conductor, PVC insulated, PVC sheathed, braided, shielded, control cable

Suitable for being laid indoors, in cable trench, pipelines or other specific occasions that demands shielding.

KVVP2

copper conductor, PVC insulated, PVC sheathed, copper-tape shielded, control cable

KVV22

copper conductor, PVC insulated, PVC sheathed, steel-tape armored, control cable

Suitable for being laid indoors, in cable trench and pipelines, directly burial or other specific occasions with a relatively large capacity for mechanical stretching force.

KVV32

copper conductor, PVC insulated, PVC sheathed, thin steel wire-armored, control cable

Suitable for being laid indoors, in cable trench, pipelines, silo or other specific occasions that demands shielding.

KVVR

copper conductor, PVC insulated, PVC sheathed, flexible, control cable

Suitable for being laid indoors and places that demands moving cables with flexibility.

KVVRP

copper conductor, PVC insulated, PVC sheathed, braided shielded, flexible, control cable

Suitable for being laid indoors and shielded places that demands moving cables

 

Q: I have a Chevy 350v8It's not shifting when it should be. It's not shifting up at all. (its not a damaged transmission)-Where is the kickdown cable?-How do i adjust it to shift the trasmission up when the RPM reaches a certain place?Right now it has problems shifting up through gears at HIGH RMP.Could it be something else? I just changed the tranny fluid and filter.
The kick down is just that when you step hard on the gas it kicks the tranny down a gear. Check for a loose or broken vacuum line to the modulator valve or the modulator itself.
Q: A tech came out and said I had to tell my landlord. I do live in an apartment, but I have the wire maintenance plan. I do have an HD box, but the HD doesn't look as clear as it should. The cable is frayed slightly and I did a self install kit. I know what I'm doing, so should the RG-59 be replaced with RG-6? And will charter do it?
This may be beyond your control: When the tech told you that the landlord needed to be told, it appears that the cabling problem exists between Charter's entry point in the building to the entry point in your unit. Which is your landlord's territory, requiring your landlord to make the work request to Charter. Sounds like you've done all you could. RG-59 from the wall outlet to your cable modem is sufficient. You could swap it out w/ RG-6 but, because the run should be relatively short, I don't think you'll see enough of an improvement to support broadband. Wire Maintenance will only support what you have control over, which is from the wall outlet to any wiring in your unit. Now, your landlord may make the request to get Charter to do the fix, but you may end up having to pay for it unless Charter allows the work under Wire Maintenance. Good luck.
Q: I have one of those cheap Chinese imported mopeds and recently the steel cable that controls the brake detached from the brake handle mechanism. The cable was attached through a small hole near the brake handle. How do I reattach this cable? Again the cable itself is not broken, it has just detached from the hand brake area.
Also lube your cables and the control points they go to with wd-40 it helps maintain them. just shoot it inside the cable as best you can.
Q: I have a 2002 Suzuki aerio with factory cruise control and when i activate it the light says its on but when i let off the gas it does nothing I've gotten it to work like 3 times other than that it doesn't work any suggestions on what it could be? any and all suggestions would be help full
Cruise controls are actually very complex systems. It sounds if the light is lighting up - it has power and thinks it is set. The system consists of a computer module, a servo box to run the throttle and the various switches and wires to control it all. The module and the servo may be combined. the servo powers a cable to the throttle body - or into the car attached to the accelerator pedal. The servo is under the hood and will have a cable as described and a wire with a large connector attached to it. Check the cable attachment. Check the wire plug. Maybe unplug it and replug it in case of loose connections. it will have a hook latch on it so release it properly. There are about 13 circuits and 6 switches that make it work. Unless you have a volt ohmmeter and get the service mmanual- you better entrust it to an electrical technician.
Q: I know that it will pollute more, and can damage the kat if is out for long times. but i'm having some problems and i believe it's the EGR. It' a bit oily around the EGR valve, i just removed the electric cable from it. Is it closed now? can it be still open?(I have a 2004 mitsubishi carisma, 1.9diesel engine)
The cable you disconnected is not only the control cable. The valve is a mechanical devise and is operated by exhaust pressure. The connection is to inform the Engine Management Computer of the position of the valve as well as a trigger. The valve can be opened by exhaust pressure. As a test ONLY - to identify the cause of your problem, or to eliminate or condemn the EGR valve, you can remove the valve and cut a piece of soda can to block off the port and replace the valve over the metal plate. This will allow you to determine if or not the valve is contributing to your problem. NOTE: Don't allow the plate to remain longer than it takes to perform your test. It can cause serious engine damage, will cause emissions to rise beyond acceptable levels, and it is illegal, punishable by very stiff fines and penalties.
Q: Every time i ask this question it gets deleted. The last time i asked it. It wasn.t even deleted it was just gone. As if i never asked it.
TV can be used to spread messages from people trying to mind control you, like a cult leader.
Q: could i carefully bend and angle a fibre optic cable to control a speaker system by IR remote, from an angle that i normally couldnt reach, due to a bad line of sight?
yeah fibre optic cables transfer light visible or not so infra red would go through
Q: I need to run 4160V feeds to some power vaults. Each Power vault requires three power feeds, a ground and a control cable. I've got existing 4 conduits.but I cannot find a cable small enough and think I need to retrench and run new conduit to at least 5, maybe 6 Anyone got a miracle solution ?
If you're dealing with 4000+volts of power ( I assume thats what you mean, 460 3ph isn't really high voltage and you shouldn't have a problem running that through 4 conduit so) You should either know what you are doing or go to someone who does - you should not be looking for an answer on here. There is no miracle solution when dealing with that much power.
Q: I keep getting a lot of static in my headphones when I wiggle the cord, so I'm assuming it's messed up. Does anyone have a good place to buy Monster Beats by Dre cables? (Can be normal, control talk, or isonitalk, it doesn't matter).
I've okorder
Q: RVV-PVC sheathed PVC insulated flexible cable is a wire or cable or a power cable? How to calculate the carrying capacity? Or who is to provide a current carrying table. Thank you all for more
Distinguish between the wire and the power, the prefix wire U is less than 1KV, the prefix power is the opposite is greater than 1KV (the former maximum voltage of the latter minimum voltage), RVV belongs to the former, the jacket wire shop for sale!
Only by offering high quality products and service, can we reach a win-win situation with our clients. We are looking forward to establishing relationships with you in the near future.

1. Manufacturer Overview

Location Henan,China
Year Established 2010
Annual Output Value
Main Markets 25.00% Africa
20.00% Southeast Asia
15.00% Eastern Asia
15.00% Mid East
7.00% South Asia
5.00% North America
3.00% Northern Europe
3.00% Eastern Europe
2.00% Central America
2.00% Oceania
2.00% South America
1.00% Western Europe
Company Certifications HACCP;ISO 9001:2000;ISO 9001:2008;QS-9000;ISO 14001:2004;CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Qingdao,Shanghai,Tianjin
Export Percentage 41% - 50%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, Arabic, French, Russian, Korean, Hindi, Italian
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches