Perkins Silent Genset Diesel Generator , 45kw To 880kw AC Generator

 

 

Quick Detail:
 

1.uk perkins water cooled diesel engine

2.electronic gevernor

3.ac brushless alternator:stamford ,marathon

4.automatic start/stop with AMF

5. 220V/380V,230V/400V,50Hz/60Hz

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70dba< span="">

 

Optional:

1. Trailer type

2. Soundproof / water proof

3. ATS (automatic transfer switch)

4. Parallel system

5. Remote system

 

PMC System:

1. Standard 23 pitch windings avoid excessive neutral current

2. Permanent magnet generator system provides constant excitation under all condition

3. Optional accessories available for easy paralleling with mains or other generators

4. AVR auto voltage regulation, auto exciter, auto adjustment

 

 

 

Q: The problem of single chip machine controlling motor
Model all MCU can be, I feel the difficulty in stepper motor control, buy the finished product of stepper motor drives, you only need to send pulse with single-chip computer. I don't feel the need for this application, you can control it on your own IO. Because I don't have the experience of this, it's a discussion.
Q: What is the difference between a step motor and an ordinary motor
The step motor is in the position control general motors are usually the speed control and the control of the two is different. Position control means that you can set the number of times you want your motor to rotate (a circle of 360 degrees), and speed control means how much your motor is going to turn/minute. This can be seen in the low speed of the step motor, which is the high speed of the motor.
Q: How do you differentiate the converter motor from the general motors?
Variable frequency motor and the common one of the biggest difference is the fan cooling way, general motors was the cold, the fan on the motor shaft, changes with the rotational speed of the motor, so the ordinary motor at low frequency heat dissipation is not ideal. Frequency conversion motor cooling fan is behind the motor equipped with a cooling fan, need an external power, the fan will not be affected by the speed of the motor, is a strong refrigeration.
Q: The difference between high voltage motor and general motors
The difference first is that in the voltage, the common motor that is common in the industry is not distinguishable, usually, 380,550,750,800. On the upgrade is usually the medium voltage motor for communication, and I have been debugged with two voltages of 1650 and 3300. The next level is the high voltage motor, which is more than 6000.
Q: The difference between ordinary motor and permanent magnet motor
There are two different kinds of classifications that you can't compare. Permanent magnet motor is called permanent magnet motor, not permanent magnet (electromagnet) for permanent magnet. Dc motors with direct current, no direct current (alternating current) is ac motor. A permanent magnet can be a dc motor or ac motor (for example, a home breeze fan). In the same way, no permanent magnet can be either a dc motor or ac motor, or even an alternating current.
Q: Is permanent magnet power saving?
The permanent magnet motor compares other motor moments under the same input power and consumes less power at the same moment. But the price is higher. The difference between the two is a few years old if it is counted as a savings.
Q: What is the difference between a servo motor and a direct drive motor?
These two are not a concept Servo motor means that this motor is driven by high frequency pulse driven by servo actuator, which can achieve fixed Angle, fixed speed and fixed torque output. He's talking about the type of motor. A direct drive motor is a direct and rigid connection between the motor and load, without any transmission or coupling in the middle. He's talking about how the motor is used. The servo motor can be connected directly to the load or through the transmission device load. The dc motor can be a servo motor or other motor.
Q: What are the characteristics of plateau motors? Why can't the general motors be used for plateau areas
Compared with ordinary motor, plateau motor is adjusted for insulation strength, electrical clearance, temperature limit and anti-halo measures. 1, the increase in elevation causes the insulation strength to decrease: the insulation intensity should be reduced by 8 to 15% for every 1000 metres. 2, the breakdown voltage of the electrical clearance is decreased, so the need to increase the electrical clearance in accordance with the elevations. For high voltage motor, the initial voltage of the corona is reduced, and the anti-stun measures should be strengthened. The cooling effect of air dielectric decreases, the heat dissipation capacity decreases, the temperature rise increases, each increase of 1000M, the temperature rise should increase by 3-10%, so the temperature rise limit should be corrected. The high altitude is unfavorable to the dc motor. Pay attention to the choice of carbon brush material.
Q: Can you use a transducer to control the general motors? Recently, the factory has to renovate two 150 kw electric motors, which were previously controlled by the star delta, and now change the frequency converter, the electric motor is near the stove, the ambient temperature is higher. Please give me your opinion, thank you
First introduce the frequency conversion motor: look from the appearance, the most obvious is characterized by frequency conversion motor have a single cooling fan, and a cooling fan has a special connection box. The cooling fan needs to be connected to the power supply alone, so that no matter how often the motor works, it will not affect the heat dissipation of the motor. Second, the frequency conversion machine manufactured by the regular manufacturer will be adjusted internally, and it will also strengthen insulation. If there is a problem with ordinary asynchronous motor, it should be analyzed according to the situation. For example, the motor is working in low-frequency areas, and the motor may be damaged by heat dissipation. If the motor is working in the medium-high frequency area, the ordinary motor can also use the frequency converter. Also, it is the insulation problem of ordinary electric motor, the proposal is to install output reactor. Of course, it's not necessary.
Q: Can a converter control a general electric machine
First introduce the frequency conversion motor: look from the appearance, the most obvious is characterized by frequency conversion motor have a single cooling fan, and a cooling fan has a special connection box. The cooling fan needs to be connected to the power supply alone, so that no matter how often the motor works, it will not affect the heat dissipation of the motor. Second, the frequency conversion machine manufactured by the regular manufacturer will be adjusted internally, and it will also strengthen insulation. If there is a problem with ordinary asynchronous motor, it should be analyzed according to the situation. For example, the motor is working in low-frequency areas, and the motor may be damaged by heat dissipation. If the motor is working in the medium-high frequency area, the ordinary motor can also use the frequency converter. Also, it is the insulation problem of ordinary electric motor, the proposal is to install output reactor. Of course, it's not necessary.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords