Cummins 20-200 KW Silent Type Diesel Generator Set


Technical Date


YIHUA- DCEC CUMMINS series diesel generator power coverage from 16kw~220kw
Adopting  DCEC Cummins, it's manufacturing base invested by Cummins in China, who is specializing in low or medium power diesel engine .The prime products are 4B,6B,6C,6L series diesel engine Gen-set. with globally uniform quality standard, compact structure ,reliable capability, high ly durability, safety and emission.

Power coverage from 16kw~200kw
Model: GF: Open type &GFS: Soundproof /Silent/Supper silent type
Engine: DCEC Cummins
Speed: 1500/1800rpm
Alternator: Stamford /Leroysomer /Marathon/ABB/YIHUA YHG

IP &Insulation Class: IP22-23 &F/H
Frequency: 50/60HZ
Controller: Deepsea/Comap/Smartgen/DKG/Others
ATS  System: Smartgen/ABB/SOCOMIC /Others
Silent&Supper silent  Gen-set Sound level: 63-75db(at 7m side)




Generator set Techinical specification

generator set performance

Engine performance

Dim.L*W*H

Genset model

Prime power

Standby power

Fre.

Model

Power

Full load
Fuel Com.

Open type

Weight

KW

KVA

KW

KVA

HZ

KW

(L)

(mm)

(kg)

GF/GFS-C16KW

16

20

26

32.5

50

4B3.9-G1/G2

24

5

1700*750*1150

850

GF/GFS-C20KW

20

25

26

32.5

50

4B3.9-G1/G2

24

6

1700*750*1150

850

GF/GFS-C30KW

30

37.5

33

41.3

50

4BT3.9-G1/G2

36

8

1820*760*1150

900

GF/GFS-C34KW

34

42.5

37.4

46.8

50

4BT3.9-G1/G2

36

8

1820*760*1150

950

GF/GFS-C40KW

40

50

44

55

50

4BTA3.9-G2

50

9.8

1950*830*1150

1050

GF/GFS-C45KW

45

56.25

49.5

61.9

50

4BTA3.9-G2

50

13

1950*830*1150

1070

GF/GFS-C58KW

58

72.5

63.8

79.8

50

6BT5.9-G1/G2

86-92

23

2150*880*1350

1120

GF/GFS-C68KW

68

85

74.8

93.6

50

6BT5.9-G1/G2

86-92

23

2150*880*1350

1120

GF/GFS-C80KW

80

100

88

110

50

6BT5.9-G1/G2

86-92

23

2150*880*1400

1120

GF/GFS-C90KW

91

113.75

100.1

125.1

50

6BTA5.9-G2

110

23

2350*950*1360

1200

GF/GFS-C100KW

100

125

110

137.5

50

6BTA5.9-G2

110

23

2350*950*1360

1235

GF/GFS-C110KW

110

137.5

121

151.3

50

6BTAA5.9-G2

120

26

2350*950*1360

1400

GF/GFS-C128KW

128

160

140.8

176

50

6CTA5.9-G2

163

33.9

2470*950*1430

1900

GF/GFS-C144KW

144

180

158.4

198

50

6CTA5.9-G2

163

35.1

2470*950*1430

1900

GF/GFS-C150KW

150

187.5

165

206.3

50

6CTA5.9-G2

163

35.1

2470*950*1430

2000

GF/GFS-C160KW

160

200

176

220

50

6CTAA5.9-G2

183

38.7

2600*980*1450

2300

GF/GFS-C180KW

180

225

198

247.5

50

6LTAA8.9-G2

220

38.7

2600*1000*1450

2400

GF/GFS-C200KW

200

250

220

275

50

6LTAA8.9-G2

220

41.6

2600*1000*1500

2500

GF/GFS-C20KW

20

25

26

32.5

60

4B3.9-G1/G2

27

5

1700*750*1230

850

GF/GFS-C22KW

22

27.5

26

32.5

60

4B3.9-G1/G2

27

6

1700*750*1230

850

GF/GFS-C30KW

30

37.5

33

41.3

60

4BT3.9-G1/G2

40

8

1820*760*1240

900

GF/GFS-C34KW

34

42.5

37.4

46.8

60

4BT3.9-G1/G2

40

8

1820*760*1240

950

GF/GFS-C48KW

48

60

52.8

66

60

4BTA3.9-G2

60

9.8

1950*830*1270

1050

GF/GFS-C55KW

55

68.75

60.5

75.6

60

4BTA3.9-G2

60

13

1950*830*1270

1070

GF/GFS-C68KW

68

85

74.8

93.5

60

6BT5.9-G1/G2

92-102

23

2150*880*1400

1120

GF/GFS-C80KW

80

100

88

110

60

6BT5.9-G1/G2

92-102

23

2150*880*1400

1120

GF/GFS-C90KW

90

112.5

99

123.8

60

6BT5.9-G1/G2

92-102

23

2150*880*1400

1120

GF/GFS-C100KW

100

125

110

137.5

60

6BTA5.9-G2

120

23

2350*950*1360

1200

GF/GFS-C110KW

110

137.5

121

151.3

60

6BTA5.9-G2

120

23

2350*950*1360

1235

GF/GFS-C120KW

120

150

132

165

60

6BTAA5.9-G2

132

26

2350*950*1360

1400

GF/GFS-C144KW

144

180

158.4

198

60

6CTA5.9-G2

180

33.9

2470*950*1430

1900

GF/GFS-C150KW

150

187.5

165

206.3

60

6CTA5.9-G2

180

35.1

2470*950*1430

1900

GF/GFS-C160KW

160

200

176

220

60

6CTA5.9-G2

180

35.1

2470*950*1430

2000

GF/GFS-C180KW

180

225

198

247.5

60

6CTAA5.9-G2

201

38.7

2600*980*1450

2300

GF/GFS-C200KW

200

250

220

275

60

6LTAA8.9-G2

240

38.7

2600*1000*1450

2400

GF/GFS-C220KW

220

275

242

302.5

60

6LTAA8.9-G2

240

38.7

2600*1000*1500

2500




FAQ

1.Q: What is your MOQ of this item?

A: 1-10 piece


2.Q: What is the lead time?

A: 25-35 days after receiving your L/C or T/T deposit.


3.Q: Is it all right to make customer's own brand name?

A: We can be your OEM manufacture with your authorization of brand.


4.Q: Where is your Loading Port?

A: China Port.


5.Q: What are your payment terms?

A: 30% deposit and balance T/T against copy of Bill of Lading or L/C at sight.


6.Q: What is your company's available production capacity?

A: 3000-5000 pieces against your orders.


Q: Generator prices? Diesel generator prices?
Unit configuration (optional unit configuration on charging) is an important factor affecting the unit price, unit optional configuration: split the daily fuel tank, integrated base fuel tank, battery charger
Q: I am looking to save money on the electric/gas bill this winter and am considering a diesel generator to supply domestic power at 240 volts.Is this practical?
Not practical if you have a reliable grid connection A small generator is much less efficient (costly) than an large generator using unrefined fuel close to source bought in bulk and maintained and run at optimum load and temperature, or a constantly running wind turbine or nuclear reactor. plus you have to pay full VAT and fuel tax; electric from the grid is only 7.5%VAT
Q: HI FROM NEW ZEALAND.I HAVE A LISTER-PETTER 16 KVA DIESEL 3 PHASE GENSET WITH SINGLE PHASE SOCKET @ 240 VAC. WITH A ITALIAN ELECTRONIC DIAGNOSTICS CONTROL PANEL WITH BREAKERS ETC.WHEN RUNNING A ESAB CADDY PROFESSIONAL 140 INVERTER WELDER @130 AMPS USING 4 MM HARDFACING RODS, ON FIRST STRIKE THE GENSET CUTS OUT AND DIE.WHEN USING A COPPER WOUND TRANFORMER WELDER THE THING RUNS WELL BUT WILL NOT STOP WHEN I HIT THE KEY TO TURN OFF OR EMERGENCY STOP BUTTON.NOTE; THIS IS A STANDBY GENSET IN THAT I JUST PLUGGED IN A WELDER, THE GENSET IS NOT A DEDICATED WELDING GENERATOR.I USED OTHER DIESEL GENSETS PRIOR WITHOUT ANY PROBS.WILL ANY1 HAVE ANY CLUES? REGARDING THIS.THANKS IN ADVANCE.CHEERS CARL GIN
Does the Esab welder have high frequency? If so the high freq. is feeding back into the generator and frying the electronics. You may need to have the generators repaired. The only way to prevent damage is to turn the high freq. off, or drive an earth ground as close to the welder as possible and you have to run a wire to your grounding clamp to this ground and the machine ground needs to go to this also. You have to get the high freq. out of the circuit as quick as possible. (I have a Hobart Champion Fabshop that is notorious for this.)
Q: I am planning to buy a 20 KVA Diesel Generator. Both the vendors are confusing me over Air cooled and Liquid cooled engines. Can anyone help me to understand the pros and cons of the said engines for a commercial requirement.
CUMMINS series generating -sets are persisting on integration and maximum efficiency for its products, as well as generating-sets are the optimum choice for users not only in standby field but also in prime field .Its excellent performance and incomparable reliability are leading to the best power solutions in power generating field. Scania diesel engine ,focusing on low running cost,features as follows,fistly,the peroid of changing oil is 60% longer than others,it can be 400hours. Secondly,high efficiency centrifugal oil filter, only need to maintenance in normal condition, no need to change.Thirdly,lower fuel consumption,save cost of diesel fuel.Besides, its high reliability makes it extend its overhaul life.These features make it have high adaptive in truck,bus,diesel generator sets,and so on.It is wel-known as sweden royal engine power.
Q: I am considering buying a back-up generator system for my newly bought home, the only problem is that my home is 4,947sq. ft, and I seem to find a single generator that is capable of powering my entire, will buying a few portable or large sized stand-by generators solve my problem?
What would probably work best would be to contact your local diesel engine service centers (Detroit Diesel, Cummins) That's who supplies back up generators for businesses, hospitals etc. They can also do homes. The price is going to be extremely high compared to the ones sold at home improvement stores but those are only capable of powering a few things and are intended to only run for a few hours at a time. The diesel generator could be built big enough to power your entire home for days. These can also be integrated right into the power board of the home doing away with the need to run extension cords everywhere.
Q: Diesel fuel savers are available today for diesel engines. These can be used for most diesel engines from school buses, big rigs, cranes, off-road equipment, marine use, and generators. If a mandate was passed to require these units to be installed tremendose sums of money could be saved by end users. For more info visit bestdieselsolutions
Visit MOO JUICE and MORE. Do you really think heavy fleets do not test this stuff? And if it saves a penny a 100 on mileage do not use it?
Q: i have a 7.5 onam diesel generator that runs for 15 min and shuts down i get a code 33 (overheating)I change coolant,cap and thermostat also checked air flow Still no luck.any ideas anyone
If it has a waterpump you might need to change that.
Q: for houses operating on diesel generators and inverters
the one with the lowest wattage rating, either domestic or foreign. just make sure it is made to work with the output of your generator ie; voltage and cycles
Q: I recently seperated the generator from the engine and replaced the rear main oil seal on the engine the electric generator was only moved back about 16-18 inches to access rear main seal. job went well with no problems after completeing job I turned down rpms to about 1000 rpm It was put back in service They use it to power up refer containers from the harbor. the next day I check it and they had turned up rpms to ??? as fast as it would run and 12 refer units running off it oh it's 480 volt well it ran for a week non stop and broke down and of corse it was my fault all i did was unbolt drive plate on front of rotor from flywheel of engine .est to repair is 6,000 could this be my fault after it ran for a week or caused from hi rpms and heat related possibley
If they need a scapegoat, you're it. However if it ran for 168 hours on a diesel engine and things were not RE-torqued/double checked
Q: As the generator is for emergency, so it stopped for long time and only run for preventive maintenance, so its not accomulate running time, what is the standard to evaluate the need for maintenance ?
First make sure the fuel is fresh periodically. Old fuel deteriorates makes it hard it start and run. Second check the oil see if it is clean, check the oil filter too. Third check the fuel filter, change once a year if not used because of bad / old fuel. Forth Check the out put of the engine / voltage / oil pressure / amperage / operating temperature / current fuses / transfer switches are working properly. Listen and make sure the engine is running smooth, no misses. Should be good to go then.