Cummins 20-300KW Silent Type Diesel Generator Set
- Loading Port:
- Fuzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 500-700 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Cummins 20-200 KW Silent Type Diesel Generator Set
Technical Date
YIHUA- DCEC CUMMINS series diesel generator power coverage from 16kw~220kw 。
Adopting DCEC Cummins, it's manufacturing base invested by Cummins in China, who is specializing in low or medium power diesel engine .The prime products are 4B,6B,6C,6L series diesel engine Gen-set. with globally uniform quality standard, compact structure ,reliable capability, high ly durability, safety and emission.
Power coverage from 16kw~200kw
Model: GF: Open type &GFS: Soundproof /Silent/Supper silent type
Engine: DCEC Cummins
Speed: 1500/1800rpm
Alternator: Stamford /Leroysomer /Marathon/ABB/YIHUA YHG
IP &Insulation Class: IP22-23 &F/H
Frequency: 50/60HZ
Controller: Deepsea/Comap/Smartgen/DKG/Others
ATS System: Smartgen/ABB/SOCOMIC /Others
Silent&Supper silent Gen-set Sound level: 63-75db(at 7m side)
Generator set Techinical specification | ||||||||||||
generator set performance | Engine performance | Dim.L*W*H | ||||||||||
Genset model | Prime power | Standby power | Fre. | Model | Power | Full load | Open type | Weight |
|
| ||
KW | KVA | KW | KVA | HZ | KW | (L) | (mm) | (kg) |
|
| ||
GF/GFS-C16KW | 16 | 20 | 26 | 32.5 | 50 | 4B3.9-G1/G2 | 24 | 5 | 1700*750*1150 | 850 |
|
|
GF/GFS-C20KW | 20 | 25 | 26 | 32.5 | 50 | 4B3.9-G1/G2 | 24 | 6 | 1700*750*1150 | 850 |
|
|
GF/GFS-C30KW | 30 | 37.5 | 33 | 41.3 | 50 | 4BT3.9-G1/G2 | 36 | 8 | 1820*760*1150 | 900 |
|
|
GF/GFS-C34KW | 34 | 42.5 | 37.4 | 46.8 | 50 | 4BT3.9-G1/G2 | 36 | 8 | 1820*760*1150 | 950 |
|
|
GF/GFS-C40KW | 40 | 50 | 44 | 55 | 50 | 4BTA3.9-G2 | 50 | 9.8 | 1950*830*1150 | 1050 |
|
|
GF/GFS-C45KW | 45 | 56.25 | 49.5 | 61.9 | 50 | 4BTA3.9-G2 | 50 | 13 | 1950*830*1150 | 1070 |
|
|
GF/GFS-C58KW | 58 | 72.5 | 63.8 | 79.8 | 50 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1350 | 1120 |
|
|
GF/GFS-C68KW | 68 | 85 | 74.8 | 93.6 | 50 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1350 | 1120 |
|
|
GF/GFS-C80KW | 80 | 100 | 88 | 110 | 50 | 6BT5.9-G1/G2 | 86-92 | 23 | 2150*880*1400 | 1120 |
|
|
GF/GFS-C90KW | 91 | 113.75 | 100.1 | 125.1 | 50 | 6BTA5.9-G2 | 110 | 23 | 2350*950*1360 | 1200 |
|
|
GF/GFS-C100KW | 100 | 125 | 110 | 137.5 | 50 | 6BTA5.9-G2 | 110 | 23 | 2350*950*1360 | 1235 |
|
|
GF/GFS-C110KW | 110 | 137.5 | 121 | 151.3 | 50 | 6BTAA5.9-G2 | 120 | 26 | 2350*950*1360 | 1400 |
|
|
GF/GFS-C128KW | 128 | 160 | 140.8 | 176 | 50 | 6CTA5.9-G2 | 163 | 33.9 | 2470*950*1430 | 1900 |
|
|
GF/GFS-C144KW | 144 | 180 | 158.4 | 198 | 50 | 6CTA5.9-G2 | 163 | 35.1 | 2470*950*1430 | 1900 |
|
|
GF/GFS-C150KW | 150 | 187.5 | 165 | 206.3 | 50 | 6CTA5.9-G2 | 163 | 35.1 | 2470*950*1430 | 2000 |
|
|
GF/GFS-C160KW | 160 | 200 | 176 | 220 | 50 | 6CTAA5.9-G2 | 183 | 38.7 | 2600*980*1450 | 2300 |
|
|
GF/GFS-C180KW | 180 | 225 | 198 | 247.5 | 50 | 6LTAA8.9-G2 | 220 | 38.7 | 2600*1000*1450 | 2400 |
|
|
GF/GFS-C200KW | 200 | 250 | 220 | 275 | 50 | 6LTAA8.9-G2 | 220 | 41.6 | 2600*1000*1500 | 2500 |
|
|
GF/GFS-C20KW | 20 | 25 | 26 | 32.5 | 60 | 4B3.9-G1/G2 | 27 | 5 | 1700*750*1230 | 850 |
|
|
GF/GFS-C22KW | 22 | 27.5 | 26 | 32.5 | 60 | 4B3.9-G1/G2 | 27 | 6 | 1700*750*1230 | 850 |
|
|
GF/GFS-C30KW | 30 | 37.5 | 33 | 41.3 | 60 | 4BT3.9-G1/G2 | 40 | 8 | 1820*760*1240 | 900 |
|
|
GF/GFS-C34KW | 34 | 42.5 | 37.4 | 46.8 | 60 | 4BT3.9-G1/G2 | 40 | 8 | 1820*760*1240 | 950 |
|
|
GF/GFS-C48KW | 48 | 60 | 52.8 | 66 | 60 | 4BTA3.9-G2 | 60 | 9.8 | 1950*830*1270 | 1050 |
|
|
GF/GFS-C55KW | 55 | 68.75 | 60.5 | 75.6 | 60 | 4BTA3.9-G2 | 60 | 13 | 1950*830*1270 | 1070 |
|
|
GF/GFS-C68KW | 68 | 85 | 74.8 | 93.5 | 60 | 6BT5.9-G1/G2 | 92-102 | 23 | 2150*880*1400 | 1120 |
|
|
GF/GFS-C80KW | 80 | 100 | 88 | 110 | 60 | 6BT5.9-G1/G2 | 92-102 | 23 | 2150*880*1400 | 1120 |
|
|
GF/GFS-C90KW | 90 | 112.5 | 99 | 123.8 | 60 | 6BT5.9-G1/G2 | 92-102 | 23 | 2150*880*1400 | 1120 |
|
|
GF/GFS-C100KW | 100 | 125 | 110 | 137.5 | 60 | 6BTA5.9-G2 | 120 | 23 | 2350*950*1360 | 1200 |
|
|
GF/GFS-C110KW | 110 | 137.5 | 121 | 151.3 | 60 | 6BTA5.9-G2 | 120 | 23 | 2350*950*1360 | 1235 |
|
|
GF/GFS-C120KW | 120 | 150 | 132 | 165 | 60 | 6BTAA5.9-G2 | 132 | 26 | 2350*950*1360 | 1400 |
|
|
GF/GFS-C144KW | 144 | 180 | 158.4 | 198 | 60 | 6CTA5.9-G2 | 180 | 33.9 | 2470*950*1430 | 1900 |
|
|
GF/GFS-C150KW | 150 | 187.5 | 165 | 206.3 | 60 | 6CTA5.9-G2 | 180 | 35.1 | 2470*950*1430 | 1900 |
|
|
GF/GFS-C160KW | 160 | 200 | 176 | 220 | 60 | 6CTA5.9-G2 | 180 | 35.1 | 2470*950*1430 | 2000 |
|
|
GF/GFS-C180KW | 180 | 225 | 198 | 247.5 | 60 | 6CTAA5.9-G2 | 201 | 38.7 | 2600*980*1450 | 2300 |
|
|
GF/GFS-C200KW | 200 | 250 | 220 | 275 | 60 | 6LTAA8.9-G2 | 240 | 38.7 | 2600*1000*1450 | 2400 |
|
|
GF/GFS-C220KW | 220 | 275 | 242 | 302.5 | 60 | 6LTAA8.9-G2 | 240 | 38.7 | 2600*1000*1500 | 2500 |
|
FAQ
1.Q: What is your MOQ of this item?
A: 1-10 piece
2.Q: What is the lead time?
A: 25-35 days after receiving your L/C or T/T deposit.
3.Q: Is it all right to make customer's own brand name?
A: We can be your OEM manufacture with your authorization of brand.
4.Q: Where is your Loading Port?
A: China Port.
5.Q: What are your payment terms?
A: 30% deposit and balance T/T against copy of Bill of Lading or L/C at sight.
6.Q: What is your company's available production capacity?
A: 3000-5000 pieces against your orders.
- Q:I have a small one bed one bath home probably not over 1000ft what size portable honda generator should I buy?
- okorder
- Q:How many watts would it take to run a small cabin with just basic lights, mini fridge, stove, maybe a small tv? I was thinking a 6000 watt diesel generator.would running it every day ruin it?
- That should probably be a big enough generator to run what ur describingThe only problem you could have is with the stove. You may have to run it by itself, depending on its size some stoves can pull alot of amps. As far as running it everyday, a diesel engine is made to run pretty much non stop, that is the advantage of a diesel over a gas engineHope this helps, any other questions feel free to email or message meDoug
- Q:China Diesel older generator. Hasn't been used for years, however, supposedly started biannually. Someone messed with the wiring. rewired much of the controls and all meters appear to be working. Have 240V no load, when applying a load to one leg, the 120V drops to 0V. Suspect the exciter not working. located the the 4 Stator cables and 2 smaller wires coming from generator. Suspect the 2 smaller are the excitation wires. According to the poorly edited Chinese to English manual. I have no idea which is F+ or F- and how important will it be to get this correct when applying the 12V as suggested in the trouble shooting guide??
- If you are seeing a voltage with no load, there is at least some residual magnetism in the field. Flashing the field probably wouldn't make any difference. I'd look for an open field winding or bad regulator if your machine uses brushes. If your machine is brushless, check for an open exciter winding, bad regulator, shorted or open diodes in the rotating field or open windings in the rotating field. There's a good chance that you can find decent troubleshooting advice for your generator on the smokstak forum. Fieldlines is another good resource. Don
- Q:Did some searching, and found little other than single, model specific, manuals (either paper or on CD). The paper manuals are $50-60 each. Single model PDF manuals on CD are about $20.Does anyone know if a comprehensive set of shop service manuals is even available for Yamaha Portable Generators? (gas and diesel) I don't mind paying, but I don't want just ONE manual, I want 'em all. That way I don't have to go through this again when a different model Yamaha comes into my shop. TIA for any help!:-) ?
- floor directly to the physique, and run your cord to a robust earth floor. those areas are obtainable at your community electric supply that sells living house-wiring factors, you will want a floor rod, clamp, and a few sturdy copper cord.
- Q:I am wondering if you can burn home heating oil in a diesel engine, I have a diesel generator and I am curious if I ran out of diesel say in a bad storm and couldn't get to a station for more could i but some home heating oil in it and run it with out messing things up?
- yes you can
- Q:Are they cranked by a self starter? Is there such an immensely powerful self starter that runs off batteries and can start such a big engine?Or are they started by some gasoline powered motor?
- A diesel engine is started (like an automobile) by turning over the crankshaft until the cylinders fire or begin combustion. The starting can be done electrically or pneumatically. Pneumatic starting was used for some engines. Compressed air was pumped into the cylinders of the engine until it gained sufficient speed to allow ignition, then fuel was applied to fire the engine. The compressed air was supplied by a smallauxiliary engine or by high pressure air cylinders carried by the locomotive. Electric starting is now standard. It works the same way as for an automobile, with batteries providing the power to turn a starter motor which turns over the main engine. In older locomotives fitted with DC generators instead of AC alternators, the generator was used as a starter motor by applying battery power to it.
- Q:I want to build an electric generator from an electric motor, how do I do this?I need planes on how to build a generator from an electric motor. I am wanted to use a 16 HP Power Diesel tractor motor. Can any one help? I am useing Diesel power because diesel fuel last longer than gas when in storage. Is this correct?I want a AC Generator.
- Very simple. You need an electric motor of the same wattage as you need to generate. You will need to spin the motor a little faster than the rated RPM of the motor. (pick your pulleys carefully) Hook a small load up to the motor, spin it, hit it with a jolt of voltage. (try your 12 volt battery)It should start to generate and you can hook up a bigger load to it. Too simple? Try it.
- Q:i think having a back up generator at my home would be useful in case of winter power disruptions however and although the new generation generators are quiet enough to stand next to where would I stand with electricity suppliers ?
- No you cannot. You must place the generator outside the building and for that you need management or HOA approval.
- Q:generator is 730 kva.to check its working time, consumed diesel, i purchased a software.but i wish to know how i connect it with computer? is it safe? any precaution? any electric wiring diagram? is it safe etc. i want to use thumb scaneer as start and stop switch.
- Even some older Gen-Sets have contacts for a remote start switch. This is where you might wire in sensors to detect when commercial power is lost. You may install a relay to actuate those contacts. You can control that relay with a computer controlled module that is run by your software. The computer you have installed the thumb scanner on can control this. If the software is for this specific generator, then it may already include a remote start, as well as a logger to record start and stop times. Kits are often available.
- Q:Ford fomoco four cylinder diesel engine with a symes pump ( i think ) is there anyone out there who knows anything at all about them or has found a web site or knows anywhere to get parts or has any engine numbers i would be very great-full.
- Sounds like a ford industrial unit. There SHOULD be a number or number plate somewhere on the block, generator, and/or frame. A possible search, assuming it is a generator unit, would be the GENERATOR manufacturer.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Cummins 20-300KW Silent Type Diesel Generator Set
- Loading Port:
- Fuzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 500-700 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords