Cummins 20-300KW Silent Type Diesel Generator Set

Cummins 20-300KW Silent Type Diesel Generator Set

Ref Price:
get latest price
Loading Port:
Fuzhou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
500-700 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Cummins 20-200 KW Silent Type Diesel Generator Set


Technical Date


YIHUA- DCEC CUMMINS series diesel generator power coverage from 16kw~220kw
Adopting  DCEC Cummins, it's manufacturing base invested by Cummins in China, who is specializing in low or medium power diesel engine .The prime products are 4B,6B,6C,6L series diesel engine Gen-set. with globally uniform quality standard, compact structure ,reliable capability, high ly durability, safety and emission.

Power coverage from 16kw~200kw
Model: GF: Open type &GFS: Soundproof /Silent/Supper silent type
Engine: DCEC Cummins
Speed: 1500/1800rpm
Alternator: Stamford /Leroysomer /Marathon/ABB/YIHUA YHG

IP &Insulation Class: IP22-23 &F/H
Frequency: 50/60HZ
Controller: Deepsea/Comap/Smartgen/DKG/Others
ATS  System: Smartgen/ABB/SOCOMIC /Others
Silent&Supper silent  Gen-set Sound level: 63-75db(at 7m side)




Generator set Techinical specification

generator set performance

Engine performance

Dim.L*W*H

Genset model

Prime power

Standby power

Fre.

Model

Power

Full load
Fuel Com.

Open type

Weight

KW

KVA

KW

KVA

HZ

KW

(L)

(mm)

(kg)

GF/GFS-C16KW

16

20

26

32.5

50

4B3.9-G1/G2

24

5

1700*750*1150

850

GF/GFS-C20KW

20

25

26

32.5

50

4B3.9-G1/G2

24

6

1700*750*1150

850

GF/GFS-C30KW

30

37.5

33

41.3

50

4BT3.9-G1/G2

36

8

1820*760*1150

900

GF/GFS-C34KW

34

42.5

37.4

46.8

50

4BT3.9-G1/G2

36

8

1820*760*1150

950

GF/GFS-C40KW

40

50

44

55

50

4BTA3.9-G2

50

9.8

1950*830*1150

1050

GF/GFS-C45KW

45

56.25

49.5

61.9

50

4BTA3.9-G2

50

13

1950*830*1150

1070

GF/GFS-C58KW

58

72.5

63.8

79.8

50

6BT5.9-G1/G2

86-92

23

2150*880*1350

1120

GF/GFS-C68KW

68

85

74.8

93.6

50

6BT5.9-G1/G2

86-92

23

2150*880*1350

1120

GF/GFS-C80KW

80

100

88

110

50

6BT5.9-G1/G2

86-92

23

2150*880*1400

1120

GF/GFS-C90KW

91

113.75

100.1

125.1

50

6BTA5.9-G2

110

23

2350*950*1360

1200

GF/GFS-C100KW

100

125

110

137.5

50

6BTA5.9-G2

110

23

2350*950*1360

1235

GF/GFS-C110KW

110

137.5

121

151.3

50

6BTAA5.9-G2

120

26

2350*950*1360

1400

GF/GFS-C128KW

128

160

140.8

176

50

6CTA5.9-G2

163

33.9

2470*950*1430

1900

GF/GFS-C144KW

144

180

158.4

198

50

6CTA5.9-G2

163

35.1

2470*950*1430

1900

GF/GFS-C150KW

150

187.5

165

206.3

50

6CTA5.9-G2

163

35.1

2470*950*1430

2000

GF/GFS-C160KW

160

200

176

220

50

6CTAA5.9-G2

183

38.7

2600*980*1450

2300

GF/GFS-C180KW

180

225

198

247.5

50

6LTAA8.9-G2

220

38.7

2600*1000*1450

2400

GF/GFS-C200KW

200

250

220

275

50

6LTAA8.9-G2

220

41.6

2600*1000*1500

2500

GF/GFS-C20KW

20

25

26

32.5

60

4B3.9-G1/G2

27

5

1700*750*1230

850

GF/GFS-C22KW

22

27.5

26

32.5

60

4B3.9-G1/G2

27

6

1700*750*1230

850

GF/GFS-C30KW

30

37.5

33

41.3

60

4BT3.9-G1/G2

40

8

1820*760*1240

900

GF/GFS-C34KW

34

42.5

37.4

46.8

60

4BT3.9-G1/G2

40

8

1820*760*1240

950

GF/GFS-C48KW

48

60

52.8

66

60

4BTA3.9-G2

60

9.8

1950*830*1270

1050

GF/GFS-C55KW

55

68.75

60.5

75.6

60

4BTA3.9-G2

60

13

1950*830*1270

1070

GF/GFS-C68KW

68

85

74.8

93.5

60

6BT5.9-G1/G2

92-102

23

2150*880*1400

1120

GF/GFS-C80KW

80

100

88

110

60

6BT5.9-G1/G2

92-102

23

2150*880*1400

1120

GF/GFS-C90KW

90

112.5

99

123.8

60

6BT5.9-G1/G2

92-102

23

2150*880*1400

1120

GF/GFS-C100KW

100

125

110

137.5

60

6BTA5.9-G2

120

23

2350*950*1360

1200

GF/GFS-C110KW

110

137.5

121

151.3

60

6BTA5.9-G2

120

23

2350*950*1360

1235

GF/GFS-C120KW

120

150

132

165

60

6BTAA5.9-G2

132

26

2350*950*1360

1400

GF/GFS-C144KW

144

180

158.4

198

60

6CTA5.9-G2

180

33.9

2470*950*1430

1900

GF/GFS-C150KW

150

187.5

165

206.3

60

6CTA5.9-G2

180

35.1

2470*950*1430

1900

GF/GFS-C160KW

160

200

176

220

60

6CTA5.9-G2

180

35.1

2470*950*1430

2000

GF/GFS-C180KW

180

225

198

247.5

60

6CTAA5.9-G2

201

38.7

2600*980*1450

2300

GF/GFS-C200KW

200

250

220

275

60

6LTAA8.9-G2

240

38.7

2600*1000*1450

2400

GF/GFS-C220KW

220

275

242

302.5

60

6LTAA8.9-G2

240

38.7

2600*1000*1500

2500




FAQ

1.Q: What is your MOQ of this item?

A: 1-10 piece


2.Q: What is the lead time?

A: 25-35 days after receiving your L/C or T/T deposit.


3.Q: Is it all right to make customer's own brand name?

A: We can be your OEM manufacture with your authorization of brand.


4.Q: Where is your Loading Port?

A: China Port.


5.Q: What are your payment terms?

A: 30% deposit and balance T/T against copy of Bill of Lading or L/C at sight.


6.Q: What is your company's available production capacity?

A: 3000-5000 pieces against your orders.


Q: a factory open 8.00 am to 4.00 pm and using 80kWh der day or 10000 w electricity in a given time it generate electricity by a diesel generator. is it possible to use a small diesel generator to generate enough power to run a motor and connect that motor to large power generator to generate whole electricity need for factory
A factory operating from 8 am to 4 pm uses 80kWh or 10000w of electricity per day generated by diesel. It is possible to use a small diesel generator to generate enough power to run a motor. If that motor is connected to a large power generator, it will generate enough electricity to power the entire factory.
Q: 272 hours (x 30mph estimate) @ 1800rpm's 8,220 miles. This is a stand by generator. Make Cummings, Model 4BT, Stamford 45kW generator.
ALL engines start to turn oil dirty as soon as they are started.regardless if it's a diesel or gas engine.
Q: I am considering buying a back-up generator system for my newly bought home, the only problem is that my home is 4,947sq. ft, and I seem to find a single generator that is capable of powering my entire, will buying a few portable or large sized stand-by generators solve my problem?
If you are looking for an emergency generator capable of delivering 200A @ 240V, single-phase current (a typical whole-house size), you will be specifying a significantly large unit, something the size of a large refrigerator (on its side). If that sort of total capacity is what you want, go for it. The incremental costs for larger units is very roughly proportionate, so a unit of twice the capacity will be very roughly twice the cost. Keep in mind that these systems must be maintained properly and tested (at least monthly) regularly. If you choose a liquid-fuel model (diesel or gasoline) there is the storage and treatment issue for the tank and the fuel in it. And, as you increase size you increase fuel consumption significantly. Typically, such generators are connected only to critical systems via the transfer-switch. So, your key systems feed directly to the transfer-switch such that when there is a power failure and the generator kicks in, the transfer switch isolates those key systems from the rest of the load. In this way you could reduce your requirements to things like refrigeration, lighting, even AC and computers, leaving out items such as hot-tubs and similar. Determine your anticipated load for key items, add perhaps 25% as a safety margin and look around that capacity. MAKE SURE that you have the system - especially the transfer switch and its load - professionally installed. A mistake there could fry both your entire house system and all things attached to it, the generator, *and* get you a massive fine from your Utility. Don't mess with this.
Q: i want to see the model of this perkins generating set
are you sure its a perkins? It may be a Yanmar?
Q: If you obtained all of your energy from a diesel generator, how much diesel would you save per year by switching from incandescent to CFL? Diesel has an energy density of 36 MJ/L and your generator operates with 40% efficiency. Incandescent bulbs consume 60-100W, while CFL consumes 15-25W.
1 Kwh 3.6 MJ. If you use each light 4 hours per day, and each was 100 watts, that is 4 x 100 x 10 x 365 1,460,000 watt hours per year. That requires 1,460 x 3.6 MJ 5,256 MJ. / 0.4 efficiency 13,140 MJ. So you need 13,140 / 36MJ/L 365 Liters of diesel. If you used CFLs, at 25 watts, the answer is 1/4 of that, so 365 / 4 91.25 Liters of diesel. So the savings is 365 - 91.25 273.75 Liters savings. At $1.25 per liter, that is $324.19.
Q: I have 1500 kw load,i want install on Diesel Generator.What should be rating?
If its a pure resistive load consider the efficiency of the alternator, de-rating factors to ambient conditions etc. etc. After considering all of the above you need a 1650KVA (with 10% safety factor
Q: How much would it typically cost to rent a 6000-8000watt diesel generator for a week? I know no one here probably knows for sure, so I'm just looking for ballpark figures. Thanks.
You can expect to spend between $60-$80 per day for a diesel generator.
Q: I am looking for the stand by large generator 15-20kw (to use all the power on one transfer switch). The problem is that stand by generator require large propane tanks (expensive to install). I would like to find a stand by generator that i could run off gasoline and use all of it available power. I think this would the most economical solution. In case of propane/natural gas the cost of propane tank installation is significant. The diesel stand by generators are significantly more expensive. So far I have found tri-fuel13kw portable generator that has several outlets. In this case not all the power can be utilized.
I don't get what you mean by not able to use all the power. The generator will produce it's rated output, and little more, from one or any combination of it's outlets - single or three phase, including the 12 volt charging system. The total output of the machine is available as a function of the total load connected, not the number of plugs or the variety of outlets - it is the total load that counts. Petrol is the least efficient, and the most dangerous fuel to use and store. The amount of fires involving LPG or similar fuels is a fraction of those involving petrol in road accidents for a start. A slow speed Diesel generator correctly sized for your normal load (allow 33% additional capacity for starting induction motors etc.) will use the least fuel, and be the longest lasting by a large margin of any of the choices you suggest above. The cheapest initial option will be a petrol powered system, but the most expensive to run, and the earliest to wear out. The running costs will be much cheaper on propane etc., and the engine will run much cleaner and last longer as a result. A high speed diesel unit will cost more than the petrol version, but will not be as expensive as the better slow speed types, it will be economical, but is not going to last as well as the slow speed models. Well made slow speed diesel units will cost the most to install, but will be the most economical both to run, service and in longevity. The cheapest initial option I have found, is always the most expensive in the medium and long range. If the unit is purely for emergency power, it should be run under load every month at least, and the fuel must be kept fresh, or treated and constantly monitored to withstand long term storage - this is where the propane storage is particularly effective. The worst thing that can be done with any backup power system is to allow it to sit for any length of time without being used. Many fail at critical times because of this.
Q: I Live way out in the country and have a diesel generator.I want to switch to nuclear because it could be cheaper. I have plenty of land to dispose of any nuclear waste.
You would be shut down before you got started unless you want to go through all the red tape and bs the government would throw at you. Plus you can't just bury it anywhere it could potentially contaminate the water table.
Q: i want to put three phase current of two diesel generating sets in only three phase.
Yes you can, just make sure the connections are grounded first!

Send your message to us