Power Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 1000M m
- Supply Capability:
- 1000M Per Week m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Basic Info.
Model NO.: | NYY,NYB,YVV,VLV,VV22.VLV22,VV32,VLV32 |
---|---|
Voltage: | Low and Medium Voltage Cable |
Insulation Material: | PVC |
Current: | AC Cable |
Application: | Industrial |
Certification: | ISO |
Export Markets: | Global |
Additional Info.
Trademark: | Taiyang |
---|---|
Packing: | Standard Export Drum |
Standard: | IEC, ASTM, BS, DIN, AS |
Origin: | Henan China |
HS Code: | 8544492100 |
Production Capacity: | 200km/Month |
Product Description
PVC Insulated Power Cable (NYY, NYY-J)
1. Used as power transmission & distribution
2. Std: IEC, BS, DIN, NFC, ASTM etc
3. Make up: CU, PVC insulate
The electrical cable(electric cable) is mainly have 2 kinds listing as followings:
The PVC insulated PVC sheath power electric Cable
The conductor can be copper or aluminium; Be strands, solid, flexible.
The insualtion is PVC.
The Jacket/Sheath is PVC.
Armored or without armored
Armoured material: Can be steel tape(sta) or steel wire(swa) or others as your request!
The recommended nominal cross section is from 1.5 sq mm to 630 sqmm.
The core number can be single or multi.
The Voltage is 0.6/1kV.
The long-time working temperature of cable should not be higher than 70 celsius.
When core is in short-circuit(max 5s) the temperature should not be exceed 160 celsius.
While installation the ambient temperature should not be lower than 0 celsius.
- Q: What is the difference between the power BV line and the power YJV cable?
- You can use sc. if too long, or bend the best use of the bridge
- Q: Copper core power cable laying cable sets what fixed
- SDH is a synchronous time division multiplexing device, the electrical interface of the 2M signal into the optical interface of the high-speed signal (the use of digital fiber optic patch panel SDHsynchronousdigitalhierarchy) 155M, 622M, 2.G, 10G, etc.). 2 trillion of the signal can be in the DDF above jumper, easy to connect. The optical path signal is spanned on the ODF and is interconnected with the optical interface of the cable or other device. Usually with the network, telephone, etc. are specific business, their communication distance is limited, are generally carried through the transmission network to expand the communication capacity, extending the communication distance. SDH is the main equipment of the current transmission network. DDF and ODF are mainly used in the machine room. The physical interface between devices is BTS-DDF-SDH-DDF-BSC-ODF-MSC or BTS-DDF-SDH-ODF-BSC -ODF-MSC Of course, bsc and msc may also have a section of ODF-SDH-ODF, see the specific circumstances
- Q: how can i calculate the current carrying capacity of a power cable when the area is given?can you give me a table on this?
- Table 310.16 of the NEC (2008)
- Q: I have a power adapter that goes to a mixer (Denon DN-MC6000) and reads: INPUT 100-240V ~ 50/60Hz 1.5A, OUTPUT: 12V - 3A. Now I know this is the right adapter but I don't know if I have the right cable that goes from the adapter to the wall. I have one that says 6A 250V~ but I dunno if its the right one. I have a few others but can someone tell me what will be the right one so I don't blow up my mixer :P thanks
- This type of power cable can be plugged into any household power between 100 and 240 volts. So, any plug that fits into the wall plug is the right one. In the US and Canada the voltage is 110-120 volts. In the rest of the world 240 volts are used The plug and wire you mention is for the rest of the world. Now look at the adapter where you plug the cable into. Do they fit together? If yes go for it. If not keep looking.
- Q: VV3 * 120 + 2 * 70 cable what does it mean
- YJV cable is cross-linked polyethylene insulation, VV cable is PVC insulation, the former temperature level higher than the latter, such as the former conductor temperature can be 90 degrees, while the latter can only to 70 degrees!
- Q: I have been doing research online and have found replacement power cables from Kimber, Nordost, PS Audio, Cardas, Monster and Audioquest. While Kimber did win an award in Audiophile magazine, the write up for PS Audio's SC statement cable appears to be very good as well. Nordost makes a great product too, but have read some complaints that it actually cheats the bass. So I am basically looking to see if anyone owns any of the replacement cables from these companies or what they could recommend as a good replacement power cord.
- For many years there has been a debate within the audiophile community whether power cables influenced the sound of components. Someone finally performed a double-blind study. The only reasonable solution for such a debate. A power cord made no discernable difference in sound. Choose your power cord replacement on appearance (It’s nothing more than decoration.) I have some purty Audioquest interconnects and speaker cables.
- Q: What is the distance between the power cable and the thermal pipe when it is laid above the thermal pipe?
- How do you not say that the three-phase system or two-phase system, if the two systems is the power in addition to the voltage is equal to the current, three-phase power per kilowatt multiplied by 2 equal to the current, such as 220V, 3000W / 220V = 13.6A, 380V, 3KW * 2 = 6A. Wire 10 square below, each square can be with 5A, which is the calculation of aluminum core line, copper wire line operator count, 220V aluminum core must be greater than 2.5 square, copper core must be greater than 1.5 square, 380V with aluminum core The line must be greater than 1.5 square and the copper wire must be greater than 1 square. At this time should also consider the equipment to start the current and increase the appropriate diameter.
- Q: Cable 3 (4 × 185 + 1 × 95) What does it mean?
- According to Article 22.7.1 of the Electrical Design Code for Civil Buildings JGJ16-. the transmission lines and the electronic information system transmission lines shall be laid separately and shall be shielded when they are close to the laying of them in parallel by the construction conditions. High-voltage cable under normal circumstances is not allowed and weak cable with the ditch laying. If the relevant control cable does need to be with the high-voltage cable ditch, should be laid on both sides of the laying and keep the distance, but also pay attention to control cable shielding measures.
- Q: Well I guess the more general question is:Are quot;twin power cablescompatible with 12v accessories and motorcycle batteries to make a safe running circuit?
- In principle, yes, but it also depends on the type of bulb (single or twin-fillament). But you better have someone do it for you if you're not familiar with this kind of circuitry. There is risk of shorts and fire, unless you are sure of what you're doing.
- Q: can you use just one power (positive) cable cut it and use the rest for your negative
- Wire is wire. The only difference is the insulation color. The biggest problem in using wire with the same color insulation is that it's really easy to get them reversed. And just one fraction of a second of reversed polarity and the amp power supply (maybe other things too) is fried. If you insist on using the same color, you should slip a short piece of shrink wrap onto the end of the negative wire close to the terminal so it can be readily identified.
1. Manufacturer Overview
Location | Henan, China |
Year Established | 1995 |
Annual Output Value | USD121,752,660.10 |
Main Markets | Southeast Asia;Mid East;Domestic Market |
Company Certifications | ISO9001, ISO14001:2004, OHSMS GB/T28001-2001, CCC |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin; |
Export Percentage | 70% - 80% |
No.of Employees in Trade Department | 21-50 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 100,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | High; Average |