Crosslinked PVC insulated power cable
1, the products according to national standard GB/T12706-2002.
2, partial discharge test: rated voltage Uo to 18 kv and below cable discharge < 20 PC; Rated voltage Uo to 18 kv cable discharge < 5 PCS. .
3, 20 ℃ conductor dc resistivity: copper 0.017241 or less Ω was/mo aluminum core 0.028 or less Ω was/m.
4, combustion performance, flame retardant cable) tested according to GB/T18380-2001 standard.
Product performance:
Using features: 1, the cable's highest working temperature is 90 ℃ for a long time.
2, when the ambient temperature under installation should not below 0 ℃, the cable bending radius should be more than 20 times of cable diameter.
3, in the event of a short circuit, the highest temperature of the conductor shall be no greater than 250 ℃, the duration of not more than 5 seconds.
4, temperature under installation should not below 0 ℃.
5, short circuit, the highest temperature of the conductor shall be no greater than 160 ℃, the duration of not more than 5 seconds.
6, cable used in rated voltage, 1.8/3, 3.6/6, 6/6, 0.6/1, 6/10, 8.7/10, 8.7/15, 12/20, 21/35, 12/20 kv power transmission and distribution system.
7, YJV YJLV is suitable for indoor and outdoor installation, can withstand a certain installation drawing, but unable to bear external mechanical forces. Single core cable in ferromagnetic materials duct is not permissible. YJV22 YJLV22 applies to direct buried, able to bear external mechanical forces, but unable to bear large pulling force.
Model and name:
Model Type
The name of the Description
YJV
Copper cross-linked polyethylene insulated PVC sheathed power cable
YJLV
Aluminum conductor crosslinked polyethylene insulated PVC sheathed power cable
YJV22
Copper core with cross-linked polyethylene insulation tape armored PVC sheathed power cable
YJLV22
Aluminum conductor with cross-linked polyethylene insulation tape armored PVC sheathed power cable
Production range:
model
some
KV rated voltage
0.6/1
1.8/3
3.6/6, 6/6
6/10,8.7/10
8.7/15 ~ 12/20
18/20 ~ 26/35
Conducting wire core of nominal section was
YJV
YJLV
1
1.5 ~ 800
10 to 800
25 ~ 1200
25 ~ 1200
35 ~ 1200
50 ~ 1200
3
1.5 ~ 300
10 to 300
25 ~ 300
25 ~ 300
35 ~ 300
-
4
4-240
-
-
-
-
-
YJV
YJLV
1
2.5 ~ 1000
10 to 1000
25 ~ 1200
25 ~ 1200
35 ~ 1200
50 ~ 1200
3
2.5 ~ 300
10 to 300
20 ~ 300
25 ~ 300
35 ~ 300
-
4
-
-
-
-
-
-
YJV22
YJLV22
-
-
-
-
-
-
-
3
4-300
4-300
25 ~ 300
25 ~ 300
35 ~ 300
-
4
4-240
4-240
-
-
-
-
YJV23
YJLV23
-
-
-
-
-
-
-
3
4-300
4-300
25 ~ 300
25 ~ 300
35 ~ 300
-
4
4-240
4-240
-
-
-
- Q: Hi all, I'm moving into a new apartment August 1, and I'm wondering how far in advance I need to call the power company, cable company, etc to set up service. I know this is probably a dumb question, but throughout college I moved into apartments where at least one of the other roommates was staying (I took over someone's lease who was moving out, but the other girls stayed so I was the only new resident). But I'm moving into a one bedroom, and I've never had to set these things up before so I just thought I'd ask what the standard time frame is. Is a month enough advance notice--should I start setting this stuff up in early July? Or sooner? Again, I know this is probably dumb but I have no experience so I wanted to ask some people who've been there and done that what the procedure is. Thanks in advance!
- You only need to set up power about a week in advance. As for cable,phone,etc. they can take longer to get setup. Just call and notify them of your move in date and they'll get it scheduled.
- Q: I was watching a YouTube video awhile ago and this guy was reinstalling his cables to his amp. I heard him say that he ran the RCA one on the opposite side of the car so there won't be anymore humming? I currently have my power, RCA ,and rem wires running from front to back on the driver side. Should I re run the RCA one on the passenger side? Will my system sound better?
- Don't run ur power cables and rca cables together cause the rca might pick up sounds from the alternator . . which will be like a humming sound in ur speakers. .
- Q: Single single 10kV power cable with copper shield can wear steel pipe? What will be the impact?
- Cable 2 * NH-KW2 * 1.. the first two said two cables, KW is KVV said PVC insulated jacket control cable,
- Q: Wire and cable should be used in parallel when the attention
- MR is a metal bridge laying, the bridge width of 200 high 100
- Q: The monitor is ........ Since I have a HDMI cable will i need anything else?
- An HDMI cable is not a power cable, it is only used to view the picture from whatever source it is.
- Q: My power cable says it is plug in but will not charge it. What is wrong?
- It could be your cable or power supply unit went bad. Or, your power socket on the main board went south. The good thing about laptops is that the power supply unit is external and easy to swap out.
- Q: Can anyone explain where I need to plug in the 6-pin cable for my ATI Radeon 1650 Pro graphics card? Or any pictures/diagrams? Thanks!
- my PSU came with that adapter :P
- Q: When i want to connect two SATA hard drives do I need some power cable on slave or just to connect it with sata cable and that'it? Because I did it like that and it's not recognized. And I don't have second SATA power supply cable in my computer.
- Of course you will need power, how is it to run without it?
- Q: I have a MSI K7 Motherboard... it has a SATA power cable but no data cable. Which kind of confuses me. Please help. Thanks =)
- the prvios responses are precise, yet there is two extra issues to evaluate. a million. till you're development your very own new pc, establishing the case advert putting this 2nd stressfulpersistent in will void the guaranty on any new pc this is keep offered or oredered from dell, etc. 2. The stressfulpersistent has jumpers on it that tell the stressfulpersistent what function it has. Ie cable choose, grasp, slave, secondary slave. maximum drives are set to cable choose from the production facility, so be beneficial to plug it into the 2d plug on your unique ide ribbon cable. each from time to time you certainly would desire to alter the jumper to slave in case you purely have an ide cable with a single connector. i'd in my opinion shop the old pc working, connect it to a router/swap and share the cpersistent out. Then i'd get right of entry to the old one from my new pc and replica purely the documents i'd desire to my new one. Your documents are oftentimes placed ordinarily if no longer completely interior of your profile folder. this variety you're purely copying image documents, song, faves, etc.. Makes it much less stressful to ward off copying over a virulent disease or any corruption. reliable luck and congrats!
- Q: i have a 01 grand prix gt and i want to run the power cable to an amp , anyone know a good spot to run it?
- In that vehicle the battery is located on the passenger side of the engine compartment. There should be a large, rectangular rubber grommet located at the front of the passenger side footwell, with a large wire bundle running through it. I usually route the power wire through that grommet, or drill a hole right next to it. It's important to carefully route and secure the wire in the engine compartment so it can't touch hot or moving engine parts. You'll also want to make sure you seal up the hole around the power wire because it's easy for water to get in at that location.
Send your message to us
Manufacturers supply YJV - 3 * 6 + 1 * 4 power cable To report
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 1000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords