• Electric Cable System 1
  • Electric Cable System 2
  • Electric Cable System 3
Electric Cable

Electric Cable

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or L/C
Min Order Qty:
1000M m
Supply Capability:
1000M Per Week m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
 

Basic Info.

Model NO.:  N2XY, VV
Voltage:  Low and Medium Voltage Cable
Insulation Material:  PVC
Current:  AC Cable
Application:  Industrial
Certification:  ISO
Export Markets:  Global

Additional Info.

Trademark:  Taiyang
Packing:  Standard Export Drum
Standard:  IEC, ASTM, BS, DIN, AS
Origin:  Henan, China
HS Code:  8544492100
Production Capacity:  20000km/Month

Product Description

1KV, 11KV, 35KV, XLPE Insulation Steel wire Armoured Electric Cable to 11KV, 24KV, 35KV

1). Application:

For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.

-Standards / Testing Specications:

IEC 60502-1.

2). Description:

- Conductor: Solid or stranded copper or aluminum

- Insulation: Cross-linked polyethylene XLPE

- Circuit Identication: The insulation shall be red, black

- Filler: Polypropylene lament with lapped binding tape

- Inner Sheath: Polyvinyl chloride (Black)

- Armor: Galvanized steel wire

- Core-covering: Binding tape

- Outer Sheath: Polyvinyl chloride (Black)

3). Brief Construction:

Single core or multi-core

Copper or aluminium conductor

XLPE insulation

Copper tape or wire screen

Galvanized steel wire armored

PVC sheath

Rated Voltage Cores Type & Specification Description Main  Application
Cu. Core Al. Core
3.6/6kv

6/6kv

6/10kv

8.7/10kv

8.7/15kv

12/20kv

18/30kv

21/35kv

26/35kv

Single core

Three cores

YIV

YJY

YJLV

YJLY

XLPE insulated PVC or PE sheathed power cable For laying indoor, tunnel, ditch and conduits, as well as in loose soil, unable to bear external mechanical force, but bear the traction force during laid.
Single core YJV62

YJV63

YJY62

YJY63

YJLV62

YJLV63

YJLY62

YJLY63

XLPE insulated non-magnetic mental tape armored PVC or PE sheathed power cable  

For laying indoor, tunnel, ditch and underground, able to bear external mechanical forces, but unable to bear heavy pulling force.

Three cores YJV22

YJV23

YJY22

YJY23

YJLV22

YJLV23

YJLY22

YJLY23

XLPE insulated steel tape armored. PVC or PE sheathed power cable
Single core YJV72

YJV73

YJY72

YJY73

YJLV72

YJLV73

YJLY72

YJLY73

XLPE insulated non-magnetic mental wire armored PVC or PE sheathed power cable  

For laying in water and seabed, able to bear heavier positive pressure and pulling force.

Three cores YJV32

YJV33

YJY32

YJY33

YJLV32

YJLV33

YJLY32

YJLY33

XLPE insulated thin steel wire armored PVC or PE sheathed power cable
Three cores YJV42

YJV43

YJY42

YJY43

YJLV42

YJLV43

YJLY42

YJLY43

XLPE insulated thick steel wire armored PVC or PE sheathed power cable
Q: I purchased a LCD TV the other day and ran a cable line to it (via crawl space). I had to use a splitter to connect the new TV. I connected the cable directly to the TV and then the power cable to the outlet which “popped” and the power went out (breaker trips). I connect the TV power cable to a surge protector and the power goes out again (surge protector wasn’t even on). So I disconnect the cable from the tv and connect the power. Everything is fine until I try and connect the cable...let’s just say the spark was bright and hot enough to melt part of the connector on the TV! So I return the TV and get a different brand and the same thing happens when I plug it into a surge protector. To begin narrowing out possible problems I connect the cable to a regular 10 year old TV with no problems. It is a brand new cable with no cuts or fraying. Any suggestions?
Something is seriously wrong, and you may need to get an electrician on the problem. You need to check the voltage between your set and the cable with a meter. There should be little or no measurable voltage. If you are getting a reading like 115 volts, then I suspect that the wall outlet into which your TV is plugged has been wired backwards, i.e. the black wire is on the white terminal, and vice-versa. The cable is (or should be) grounded where it comes into the house, but if the outlet has the hot wire on the wrong side, this might cause the problem you described. The wrong connection could have occurred anywhere along the line between your main panel and the outlet, so this may involve checking the connections at several outlets and light fixtures - whatever is on the same circuit as your TV's outlet.
Q: Welding cable (230v) doesn't, so why would (14v) car audio cables
RCA Cables: These are the cables used to transfer pre-amp (line level) signals. Usually, you use this type of cable for unamplified signals such as the connection between your head unit and amp or crossovers/eqs. Look for appropriate thickness and shielding. The end connectors should be sturdy to prevent breakage from stress. Some claim that very expensive cable makes a difference in sound quality. I do not think so, do not spend more than $1/foot. You may need to spend more to get cables that are more immune to noise if you have that problem in your car
Q: i have a 2001 corolla with a new amplifier. when they wanted to test the amp after all wiring was done, they somehow wired the amps power cable to my negative connection on the battery. i turned on the electrics on the car and they all work. then i tried starting it, and how the engine wont start and the lights dim when im turning the key. what happened? and how can i fix this major screw up???
That means your Amplifier is connected directly to the battery -ve.Then both should work. What is the power level of Battery?If old there is a possibility of full discharge. Dim lights, are an indication of discharged battery. If discharged,re-charge it before next trial. If battery is in good charged condition,starter will work. (Otherwise,Check for any mistakes.Reinstate the connection).
Q: Where can i find the power cable for this specific TV brand ? GO-VIDEO-2050..?
Most TVs use two different types of power cable with either a normal female end or a two-prong narrow female end. Go to Best Buy and most likely you can find what you need.
Q: i bought a video card off OKorder and i did everything but i don't know if i connect both of the cables to the power supply...i currently only connected one but do i do both…
check the manual, if it requires 24v power then yes, use both. most new power supplies will come with a graphics card power connector already on them, use that if its available.
Q: Forced shut down pc now it has no power just a buzzing sound when the power cable is plugged in
well, the power supply may be dead. take it to a technician
Q: some one told me that cisco get this router without AC power it get the power from the network cable?
You need to make sure your Switch supports POE (power over Ethernet).
Q: What happen's when you just yank the power cord out from the electronic (Computer or TV) while it is still running? Does it blow a fuse or something? And what should I do to fix whatever the problem is, assumming that the electronic doesn't turn on after i yank the power cord out?
A TV probably will be OK. However if you are in the middle of something on a PC you can corrupt the hard disk. Often you can recover after doing a scan disk. Sometimes you can't so you shouldn't really do it.
Q: I have an internal SATA drive that im looking to access through my laptops eSata (external SATA) port. Im buying the cable required for this but im curious after I make the connection is there a separate cable i need to provide power to the hardrive?Or does the sata to esata cable provide power to the internal drive
An okorder / Yes you do need a separate power cable for any SATA devices, but that enclosure uses a small controller board to make a single cable design possible.
Q: i am going to establish a new power cable manufacturing business. i want to ask you what should i name to my business or what brand name should i adopt that is appopriate.
follow the suggestions. Good Luck
The company occupies about 360,000 m2, has standardized plant 15 million m2, of the cable production capacity of 80 million kilometers. Company and the following types of 35KV power cables, signal cables, computer cables, elevator cables, servo, drag chain cables, railway signaling cable, motorcycle cable, silicon rubber cables, high temperature cables, flame retardant cables, fire-resistant cables, aerial insulated wire , communication cables, marine cables, nuclear power plants such as cable and wire cloth products are widely used in electric power, telecommunications, petroleum, petrochemical, metallurgy, building materials, railway, shipbuilding and other industries and sectors.

1. Manufacturer Overview

Location Jiangsu, China
Year Established 1995
Annual Output Value USD200,752,660.10
Main Markets Southeast Asia;Mid East ;Domestic Marke
Company Certifications ISO14001;ISO9001;OHSMS GB/T28001-2001; CCC

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shanghai
Export Percentage 70% - 80%
No.of Employees in Trade Department 21-50 People
Language Spoken: English; Chinese
b) Factory Information
Factory Size: Above 360,000 square meters
No. of Production Lines Above 80
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range High; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords