• Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator System 1
  • Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator System 2
Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT or LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

 

 

Quick Detail:

1.Perkins Oringal Diesel engine:403-11G,1103A-33G,1006-6TAG

2.AC Alternator Brand:stamford,leroy somer,marathon

3.ac brushless 4 poles ,self-excited  alternator

4.deepsea,smartgen Digital auto-start panel

5.noise level:70dBA at 7m away

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

 

 

 

Q: What kind of fan is explosion-proof motor
First of all, should be clear is general explosion-proof, still be explosion-proof of coal grade. Explosion-proof motors, if applied to EXDI, should be done according to 3836.2,
Q: If the value of the capacitor on a motor is smaller, it can also be installed in other motors
Don't keep using it. The capacity will continue to decrease until it is completely invalidated and has no value.
Q: What is the difference between explosion-proof motor and ordinary motor
Compared with the general motors explosion-proof electric motor is characterized by: (1) meet the requirements of type increased safety explosion-proof motor, a series of reliable measures to prevent spark, arc and danger of high temperature, can be safe operation in explosive dangerous location 2 zone. (2) the excitation control system is reliable by using the brushless excitation, setting the rotary rectifier disc and the static excitation cabinet. It is accurate to be accurate, without impact. The excitation system loses step protection and is reliable, and the whole step is strong. The circuit design is reasonable, the discharge resistance is not hot in the work. Excitation current adjusts the scope width. (3) synchronous machine, ac exciter and rotating rectifier disk coaxial. The rectifying disk is located between the main motor and the exciter, or outside the bearing seat.
Q: What is a hydraulic motor
No hydraulic motor of this statement, first of all, the mean power as the driving force of mechanical, electrical and hydraulic two different drive mode, only the hydraulic pump and hydraulic motor, hydraulic pump is driven by motor, have a plenty of driven by hydraulic motor,
Q: Is the servo motor to be used as a common motor?
Due to the overload ability of servo motor, the rated torque of servo motor can be determined by reference to 1/3 of the output torque of the motor.
Q: The difference between plateau motor and ordinary motor
Elevation of elevation, the breakdown voltage of the electrical clearance is decreased, so the need to increase the electrical clearance in accordance with the sea level. High elevation, the initial voltage of the corona decreases, and the anti-stun measures of the motor are strengthened.
Q: How is the rated current of the three-phase machine calculated?
I want to add; The power of a three-phase motor can and should be the power of its rated output, not the power the motor inputs from the grid, which is the only title I. Calculation method is still A P = 1.732 * cos phi x efficiency, the UI is not generally take but should take 1.732, it is 3 square root of arithmetic is, U is the line voltage (380 v), some current (A), cos phi power factor < 1, efficiency (I don't know how to play this symbol)
Q: Is the servo motor more than the general motors? Why is that?
Of course, it's not the same, if it's all running at full capacity, but if you have a surplus, the servo motor will be more efficient, after all, the response is fast
Q: What is the meaning of the motor from cold and cold?
Self-cooling: the surrounding environment, and the holes in the ends of the cover, reduce the temperature of the motor Forced cooling: other help For example: add a fan to the shaft The channel is designed to reduce the temperature through the flow of cold water The oil in the transformer is cold
Q: What is the difference between an energy-saving motor and a general motor
The high efficiency energy-saving motor adopts new motor design, new technology and new materials, and improves the output efficiency by reducing the loss of electromagnetic energy, heat energy and mechanical energy. Compared with ordinary motor, the efficiency of using high-efficiency motor is obvious, and the efficiency can be increased by an average of 4%. The weight is basically the same. High efficiency energy-saving motor is the general motors with high efficiency.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords