• Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator System 1
  • Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator System 2
Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT or LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

 

 

Quick Detail:

1.Perkins Oringal Diesel engine:403-11G,1103A-33G,1006-6TAG

2.AC Alternator Brand:stamford,leroy somer,marathon

3.ac brushless 4 poles ,self-excited  alternator

4.deepsea,smartgen Digital auto-start panel

5.noise level:70dBA at 7m away

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Silent Perkins Genset Diesel Generator 50kva To 1000kva With AC Alternator

 

 

 

Q: If the value of the capacitor on a motor is smaller, it can also be installed in other motors
The capacitance is ageing and the work is unstable and soon expires.I hope my answer will help you.
Q: The difference between pulse motor and servo motor
But if you ask the difference between the stepping motor and the ac servo or dc servo, I can tell you: Stepper motor start-up needs a slow speed, and can control through pulse, and is inversely proportional to the speed and torque of the motor, the higher the speed, torque is smaller, and the highest speed is not more than 1500 r and his itself has no feedback device, speed up the easy step, and the low speed easy to shake. And other kinds of motor position control (pulse) and speed (analog control) with a feedback device, constant torque under the rated speed, the speed of tens of thousands of turn, and because there are feedback device step will not be lost
Q: Who is more powerful than the average motor and servo?
Electric power of the same motor, motor torque size is different, some torque, torque smaller. See motor iron core material permeability, high permeability of high efficiency, large torque. Servo motor iron core is rare earth materials, ordinary motor iron core is silicon steel material.
Q: What is the difference between a three-phase asynchronous motor and a regular motor?
Three-phase asynchronous motor cooling fan is fixed on the motor shaft, the same as the rotation speed of the motor, low frequency is run, the fan is running at low speed, the cooling capacity drops greatly, the heat generated by the motor can't send out, serious when burning motor. The structure and pressure capacity of the inverter motor are specially designed to accommodate high speed and high harmonics. Motor has the branch of general motor and frequency conversion motor, called main appearance is different from ordinary motor frequency conversion motor frequency conversion motor is packed with centrifugal fan forced cooling, this ensures the motor at low frequency and high frequency heat dissipation is good, and frequency conversion motor internal structure can adapt to the high frequency operation of specific working frequency range see nameplate. General motors generally allow only running under 50hz.
Q: What is the difference between a general motor and a high-speed motor?
Ordinary ac motor is restricted by the maximum synchronous speed, which can not reach high speed, dc motor (especially brushless motor) can achieve higher speed. The static balance and dynamic balance of high speed motor are high.
Q: Can I use the servo motor?
You can use it as an ordinary motor, the premise is the drive still need to use, can be set to Cn001 is 1, speed control, select Cn002.0 is 1, do not use the input node SON control servo, servo power immediately started. The Hn505 is H010A, which selects the internal velocity; Sn201, you can set the speed you want. The two strands of the electric motor, the four line is the power, the three phase four line, the like you have been to the end to scrap more than n many RMB, the ninth line is the encoder line, must connect well. After this is done, you can be overqualified.
Q: Does the motor swing around?
The rotation must be oscillating, and the motor will also produce the left and right swings of the left and right sides
Q: Can ordinary motors use a frequency converter?
Motor insulation strength problem Small and medium frequency converters, many of which are controlled by PWM. He is about several thousand to more than 10 KHZ carrier frequency, which makes the motor stator winding to withstand high voltage build-up rate, equivalent to impose great impulse voltage gradient on motor, the motor of the turn-to-turn insulation withstand ordeal. In addition, the rectangular produced by PWM inverter chopper superposition of impulse voltage on the motor running voltage, would pose a threat to ground insulation of motor, the ground under the repeated impact of high voltage insulation can accelerate ageing. 3, harmonic electromagnetic noise and vibration Ordinary asynchronous motors, when powered by a frequency converter, can complicate the vibration and noise caused by factors such as electromagnetism, mechanical and ventilation. The internal harmonic interference of the different time harmonic and the electromagnetism of electromagnetism in the frequency conversion power supply, form various electromagnetic excitation forces. When the frequency of the electromagnetic wave is consistent or close to the natural vibration frequency of the motor body, the resonant phenomenon will be generated to increase the noise. Because the frequency of the motor is wide, the speed varies widely, and the frequency of all kinds of electromagnetic waves is difficult to avoid the natural vibration frequency of each component of the motor.
Q: What is a permanent magnet motor? Is there a difference between a regular motor
A permanent magnet is a magnet that doesn't need to be charged by the current itself, and electromagnetic relays that require electrical flow to be magnetic. Permanent magnet motor and ordinary motor stator magnetic objects, not as electromagnetic relay, because the motor works by magnetic current ~ ~ hope to adopt building Lord ~! one
Q: What is the difference between an energy-saving motor and a general motor
Contrast with the normal Y series: losses of 15% to 25% and efficiency up 2.5% to 4%. 4. With the improved ventilation systems using highly efficient energy-saving fan of energy-saving motor air gap, the flux density distribution of reasonable design, make the motor efficiency index reaches more than GB18613-2006 grade 2 energy efficiency standard. Our energy-saving motors have outstanding features: 1. Efficient energy efficiency, lower running costs, and allow the final customer to recoup their investment costs within 9-15 months. Reliable performance is high, making the supporting equipment running smoothly, the failure rate is low, the maintenance cost decreases. Adopting imported high-grade bearing, manufacturing process is exquisite, once used, benefited from many years. Can be equipped with various accessories, the installation method is suitable for many situations. The product standard we adopt is at the cutting edge, the insulation and insulation are extremely abundant, the structure design takes care of and satisfies different customers

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches