Hot Dip Galvanized Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Q: I wired an outdoor lamp-post. I tested it before wiring it to the fuse box...and if I touch the lamp-post I feel the current (a slight shock). I will be using a ground fault breaker....so I assume if I wire it to that I am going to loose the connection. Any thoughts on what is wrong?
You likely scratched the wire somewhere. When I did an outdoor shed the wire made a corner on some metal and scratched the insulation. It is a leak rather than hooking up the wrong wire, otherwise you would have gotten more than a tingle. First I would examine everywhere the wire comes in contact with the post. Second Check all the connections to see if some were improperly taped, or the wire was cut when stripping.
Q: I just installed a backup camera however I am having trouble wiring it. I've read that I need to tap into the reverse wire, however I went through many wires and couldn't figure out which one is it. My cameras wire is designed to be wired in the trunk, so the wire under the hood or dash is not a possibility. 2003 G35 Sedan
You can remove your tail light and tap into the reverse wire there. It is easy to find just look at your reverse light bulb and use a multimeter to test for positive and negative (that would be the right way to do it at least). If your wanting to have the camera able to be on all the time and viewed from the headunit then you would need to wire the camera to switched accessory so it has power when the car is on and hook up your head units wiring (which you will need to do anyway to make the h/u switch to b/u cam when you go into reverse) to the reverse wire.
Q: well i've been asking for quite sometime on the correct wiring of a bathroom fan up to the same circuit as my light in the bathroom but i believe i've figured out. but i have a question now about the wire guage.the wire guage in the house is the standard solid 12 or 14 i think(house built in 50's) and the the wire that came with the bathroom fan looks a little smaller or about same size but it's braided .it should be fine to splice the two right?
Yes, you can. Use insulated wire nuts. I always wrap the wire nut and connection with electrical tape. Safety First! Also my parents have house that was built in 1908 and they didn't use a ground back then. Make sure your house has one.
Q: Does anybody know where on the internet i can find the radio wiring diagrams of a factory radio???
Dont cut the wiring to fit a new stereo...! Halfords do wiring harnesses changing one type to another. (?20) If its already cut, use a car electrician to be safe.
Q: The drawing shows two long, straight wires that are suspended from the ceiling. The mass per unit of length of each wire is 0.050kg/m. Each of the four strings suspending the wires has a length of 1.2m. When the wires carry identical currents in opposite directions, the angel between the strings holding the two wires is 15 degrees. What is the current in each wire?? Im not sure what equations to use for this problem.
Wiring that previous could desire to get replaced. Insulators wreck down over the years. In Edison's day insulation became into, rope and tar, or fabric, with glass insulators to guard lumber. you like a rectifier to create pulse ac (see image voltaic Panel grant) i hit upon it not straight forward to have faith anybody might grant DC power. The generator could desire to be on the threshold of factor to apply, do to severe voltage drop in DC cutting-edge over long distance. through fact of this AC is used now. till that's an Edison Museum image voltaic power is DC too. I advise studying image voltaic power for ideal DC wiring practices. I actual have been a electrician my total existence and know little or no approximately DC wiring and contraptions. in case you presently have electrical energy, get multimeter attempt for ac voltage first. then DC to steer away from unfavorable the meter, to confirm what power you have
Q: Why do two parallel wires carrying currents in opposite directions repel each other?
Each of the wires is under the influence of the circular magnetic field produced by the other wire. If you apply Fleming's left hand rule, you will realise that the mechanical force experienced by each wire under the influence of the magnetic field of the other is in opposite direction. So, as the mechanical force on each wire pulls it apart from the other wire, there is repulsion between the two wires. Was this helpful?
Q: me and my friend were doing a circuit challenge and we did the same circuit but she used thicker wires. does it make a difference?
Thicker wires = larger path for electrons to flow through. If the wire was thin, not as many electrons go through it. But a bigger wire means the electrons flow faster and the overall system receives and gives off energy faster.
Q: i have 4 wires going to a ac unit #10 wires 2 wires for each cir. and i need to know how many amps can I run with 2 #10 copper for one side of the breaker
10 wire is rated for a maximum of 30 amps. This size wire can not be run in parallel to carry more current. I suggest that you have a local qualified professional electrician do the work since you seem unsure about what you are asking.
Q: can aluminum wiring catch on fire
It can be, but you have to be careful when ever you replace an outlet or switch that you get the one that is special for aluminum wiring, other wise it can be a fire hazard. It is no longer allowed by code for new homes, but existing homes are safe as long as you understand the limitations.
Q: I have a 98' F-150 and need to add a 4 flat trailer wire connector to it. What all do I need to do? Is their a special connector?
Your friendly neighborhood auto parts store should have a wiring kit for your truck... complete with instructions and diagrams.