Steel Wire Rod in Coil
- Loading Port:
- XINGANG PORT,China
- Payment Terms:
- TT or LC
- Min Order Qty:
- 25 Tons m.t.
- Supply Capability:
- 100,000 Tons Per Month m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications of Steel Wire Rod in Coil:
Steel Grade: Q195/235, SAE1006-1018B Standard: ASTM, GB
Diameter: 5.5mm, 6.5mm, 7mm,8mm,9mm,10mm,12mm,14mm
Type: Drawn Wire Alloy or Not: Alloy Brand Name: HSKY
Technique: Hot Rolled Place of Origin: China Mainland
Chemical Composition:(Please kindly find our chemistry of our material based on SAE1006B and SAE1008B as below for your information)
Grade | Chemical Composition (%) | |||||
C | Mn | S | P | Si | B | |
SAE1006B | 0.03~O.07 | 0.32max | 0.045max | 0.040max | 0.30max | 0.0008min |
Mechanical properties | ||||||
Yield strength(N/mm2) | Tensile strength(N/mm2) | Elongation (%) | ||||
250-280 | 350-380 | ≥32 | ||||
Grade | Chemical Composition (%) | |||||
C | Mn | S | P | Si | B | |
SAE1008B | 0.10max | 0.3~0.50 | 0.050max | 0.040 max | 0.15max | 0.0008 min |
Mechanical properties | ||||||
Yield strength(N/mm2) | Tensile strength(N/mm2) | Elongation (%) | ||||
≥195 | 315-430 | ≥30 |
Usage and Applications of Steel Wire Rod in Coil:
After hot-rolled the products shaped into coil and delivery as finished product, including round, square, rectangular, hexagonal and so on, Since most of the products are round, it is generally called wire rod. Steel wire rod is widely used in construction and manufacturing. Steel wire rod is mainly used for reinforcement of reinforced concrete and welded structure or reprocessed (roberts, nail etc) materials, especially used to produce wire drawing, welding electrode, nails,spring, electronic, precise machinery parts and so on.
Packaging & Delivery of Steel Wire Rod in Coil:
Packaging Detail: products are packed in coil and then shipped by container or bulk vessel
Each coil weight: 2-3MT
Delivery Detail: within 45 days after received deposit or LC.
Label: to be specified by customer, generally, each bundle has 1-2 labels
Trade terms: CFR, CIF
Steel Wire Rod in Coil in Container
Steel Wire Rod in Coil in Bulk Vessel
Note:
1. Our products are produced according to national standard (GB), if not, supply according to national standards (GB) or agreement as customer required.
2. Other Grade and Standard carbon steel wire rod we can supply:
Grade: H08A, 30MnSi, 62B-82B
Standard: AISI, BS, JIS, DIN
The Minimum Order Quantity of these products is high, and need to be confirmed.
3. We can not only supply carbon steel wire rod; if you need anything about building materials, please contact us.
4. Please send us your detail specifications when inquire. We will reply to you as soon as possible. We sincerely hope we can establish a long stable business relationship.
- Q: I recently re-wired my house with 4 wire telephone wire. They all meet in the attic. How do I wire them together and is there some kind of junction plate I can use? Additionally, I did also wire my house with Cat6 wire, but would like to keep it strictly for Internet.
- (links just for reference, from search engine results)
- Q: Theirs a green ground wire, a white neutral wire and for some reason 3 black wires.
- it could be for the lights if its an option otherwise connect all the black together to the hot wire. What does the instructions say? worst it can do is trip the breaker.
- Q: I am connecting a humidstat to furnace. I would normally use furnace/thermostat wire for this purpose except that I need 8 conductors and the largest furnace/thermostat wire seems to be 5 conductors. I would like to use another 18guage 8 conductor wire but not sure if there are any specifications I need to ensure it meets before I can use it inside furnace cabinet.
- Standard 18 gauge wire is all you need, they do make it in 8 and 10 conductor, it just takes a little calling around to supply houses to find it. There's is nothing special about the wire specs for thermostat wire as it relates to your furnace so long as you use 18 gauge standed or solid wire. The only exception for thermostat wire is when you get into commercial buildings with an open plenum return air system, any wire used in the plenum cavity must be plenum-rated, which is almost always much more expensive.
- Q: Ok, I am having trouble installing a new car radio in my 97' Honda Civic Lx. It's just a basic pioneer cd player.. I matched all the colored wires up and still nothing. My brother had told me something about + - for example do i hook the green stripped wire with a flat green wire? Vice versa.. Help please.. Also If you know of a web site with diagrams?
- Car Stereo Radio Wiring Diagram - 1997 Honda Civic Radio Constant 12V+ Wire: Blue/White Radio Switched 12V+ Wire: Yellow/Red Radio Ground Wire: Black Radio Illumination Wire: Red/Black Radio Dimmer Wire: n/a Front Speaker Size and Location: 6 1/2″ Doors Left Front Speaker Wire (+): Blue Left Front Speaker Wire (-): Gray/Black Right Front Speaker Wire (+): Red/Green Right Front Speaker Wire (-): Brown/Black Rear Speaker Size and Location: 6″ x 9″ Rear Deck Left Rear Speaker Wire (+): Blue/Yellow Left Rear Speaker Wire (-): Gray/White Right Rear Speaker Wire (+): Red/Yellow Right Rear Speaker Wire (-): Brown/White
- Q: In a telephone splice case, do you have to strip the 2 wires you want to splice, and put them together, or does each wire that you want to connect attach to terminals in the case? I am talking about the black cases on a utility pole, that the residential phone wiring connects to.
- You are only responsible for the wiring to the dmark - on my house, it is a small green box attached to the side of my house. If you are talking about something beyond that, I can not / will not assist you. Can you please clarify?
- Q: What are the effects on an amp when you use power/ground wires that are too small? I bought a set of 8 guage wires off of OKorder, and it stated they can handle up to 1000W. I'm using a Kenwood KAC-9103D amp, 500x1 @ 4ohms, 900x1 @ 2ohms, and 900+ x1 @1ohm (1800 W max power). My subs are Kicker VR8, dual voice coil, 4ohms, wired in parallel. Was it a mistake to go with 8 guage wiring? Should have I gone with 4 guage?
- definite you ought to enhance to 4gauge. a million/0 in case you may locate the money for it. it's going to make a distinction simply by fact the bigger the cord, the greater advantageous the present pass. i could recommend finding into doing the massive 3 besides. keep in mind, it takes potential to make potential. N2, yup a million/0 for 4 hundred watts. i recognize folk working a million/0 to 4 hundred watt SAX200.4s. unlike maximum folk, I constantly improve so why even purchase 4 gauge and then spend additional money on a million/0. And why shouldn't I be answering questions? I even have sufficient recognize how and am sensible sufficient to run greater advantageous issues than Pyle and twin, :D
- Q: Does anyone know where i can buy them? I need new ones because my crazy cat chewed up two of the wires lol =#92;
- Buy some speaker wire and electrician's tape and splice new wire in the area where the old wire is chewed. Make sure you don't cross positive with negative. This way, you don't have to worry about getting the right connections, and it will be inexpensive.
- Q: A wire is 1.5 m long and has a diameter of 1.5 mm. The stretch modulus of the wire is 6.2 x 10^10 N/m^2. If a force of 400 N is applied to end of the wire then the increase in length of the wire is???please help, thanks
- The stretching of wire by longitudinal force: If F force applied across the crosectional area A of wire of radius r and lenght L then the wire elaogates in the dirextion of force Stress P = F / A A = pi* r^2 = (1.5/2)*10^-3 = 7.5 *10^-4 m^2 strain produced = dL / L = increase in length / original L Young's modulus or elastic (stretch) modulus for the maretial, within elastic limits, Y = stress/strain strain = stress / Y dL = F * L / A * Y = F * L / pi (r^2) * Y dL = 400* 1.5 / 3.14 (7.5 *10^-4)^2 * 6.2*10^10) meter dL = 0.005479 * meter dL = 5.479 millimeters increase in length
- Q: What are the types of Barbed wires?
- Barbed wire is barbed wire as far as I am concerned. Otherwise google barbed wire manufacturers and see what they can supply.
- Q: wic iring codes for turner plus three wired to uniden washington cb radio
- I love wiring questions :) do you want to use the PTT? If yes you can assume it is a switch and solder it inline with the lead the other end (after the switch would be connected to the lead end of the 1/4 if you have a pigtail 1/4 then this would be the insulated wire, the ground would simply connect to the uninsulated wire if you are actually using a do it yourself 1/4 plug then the same rules apply only you are soldering to the terminal inside the plug sleeve rather then to bare wires (I always prefer this its cleaner). Please Note: The PTT switch will cause a loud pop when it is engaged and released on a Hi Gain guitar amp and sometimes this can damage the speakers as well as delicate internal components so do this of coarse at your own risk.
1. Manufacturer Overview
Location | Tangshan, China |
Year Established | 2003 |
Annual Output Value | Above US$ 750 Million |
Main Markets | Middle East; Southeast Asia; east asia; Africa |
Company Certifications | ISO 9001;ISO 14001;OHSAS 18001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin; |
Export Percentage | 50% - 70% |
No.of Employees in Trade Department | 21-30 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 1,500,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM servise offered |
Product Price Range | average |
Send your message to us
Steel Wire Rod in Coil
- Loading Port:
- XINGANG PORT,China
- Payment Terms:
- TT or LC
- Min Order Qty:
- 25 Tons m.t.
- Supply Capability:
- 100,000 Tons Per Month m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords