Hot Dip Galvanized Steel Wire For Gabion
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Commercial Galvanised Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q: I am looking for some answers when it comes to soldering wires. Lets say I am using 6 to10 (22 AWG 2 conductor wires) and I want to solder those to 1 wire for power source and 1 wire for ground. Now lets say soldering 10 wires to 1 wire for power and 10 wires to 1 wire for ground. All the wires are the same AWG guage. Now that the wires are twisted together and soldered to the hot and ground source, by doing this will I actually make a resistor or change the amperage or reduce the voltage by soldering so much wires together to a 1 wire source? The power source I am using is 12 Volts. If anyone knows of anywhere I can find this information online, etc, I would appreciate it.
- it will effect the voltage because it will split the power 10 defferent ways. i dont know any website that will tell you this but there is a tester that you can get to test the voltage. thats how i found out.
- Q: Does lime wire add a lot of pop-ups and slow down your computer?
- I by no ability had any problems with Limewire messing up my pcs overall performance in my view, yet once you're asking approximately your pc's protection, there are different pretend downloads which will provide your pc viruses. My terrific suggestion is to preview the record in the past you end the obtain. If Limewire is rather messing up your pcs overall performance, uninstall it. in the experience that your pc maintains to run slowly, verify for viruses...
- Q: I'm faced with a dilemma...I'm wiring my basement right now and all is fine, except for my living room. I want to have a 3-way switch setup, but with four light fixtures. I've already ran 3+ground wires in this order...Breaker box - Switch A - Fixture 1 - Fix. 2 - Fix. 3 - Fix. 4 - Switch B. I have done regular 3-way switches in the past, without much trouble, but I have no idea how to wire this, so well-explained instructions would be perfect.Thanks so much!
- feels like in case you have sparks popping out of the breaker container you may desire to surrender what you're doing and step returned. A breaker container isn't a place for the susceptible at heart. That container is warm, electric powered clever. you probable have 220 volts coming in the suited of the container to the main which shuts each little thing off. i think of it could be clever to attend till day after today and flow to domicile depot. they have books on easy wiring.
- Q: why do we use copper wires as connecting wires
- copper has a physical property that is a very good conductor of electricity.
- Q: Our house ground wire is very long but our live and natural wires are very short. Once there was a surge in our telephone line system and both my Belkin Surge Protectors seemed to have not stopped it. The surge was stopped at my last protector when its sensitive fuse blew (it was a 10 ohm resistor fuse). Is it possible that since the natural wire is shorter than the ground wire the surge wantted to go through my PC and into the natural wire? Or is it just because the 10 ohm resistor fuse was a bit too sensitive or something? (Well it didn't blow up when there was no lightning outside)I'm thinking of making my natural wire longer by extending it so a surge finds the ground wire more attractive, is this advice able?
- Your ground wire should go to your breaker box, then to a ground rod or some other good ground point with a large #6 solid wire. I don't understand why your ground wire should be substantially longer than your neutral or hot wires. Making your neutral wire longer would probably have little effect. You could also have a poor connection in your ground wiring. Maybe some corrosion has accumulated somewhere. A surge protector can't operate correctly without a good ground. It sounds like you should have an electrician check your electrical system. This could save you money in the long run.
- Q: like lets i want to want to connect my speaker wires with other wires can i use elmer glue so that it sticks and will the wires still work?
- There are three methods i would use personally, glue is a terrible choice. 1. Easiest - Strip the two tips of the wire, Twist them like he stated and put electrical tape to keep the current inside and wires together. This works but the wires can slip with the slightest pull sometimes. 2. Medium but still easy - Purchase butt connections (least thats whati callem lol) - Basically its this Red/Yellow/ or blue, cylinder about an inch long and just a little thicker then the wire itself. The exterior is a plasitc like substance and the inside is a Metal tube. Strip both ends, stick them in and use a Wire Crimping tool to crimp both ends and i do the center of the connection. This gives you a secure connection with minial work. 3. More difficult - Soddering. You'll need a soddering gun and electrical tape for this and also is the best connection youll get when hooking to wires together. Strip both ends, Twine them together and then you use the soddering gun to bascially drip metal into the twisted wires connecting them forever, unless you cut them.
- Q: I connected my wires in the morning and something aint righti put two wires incorrect but i dont see it... can some oneput them together for me cuz i really cant see where i did wrongmaybe some one else will find it ...
- Radio Constant 12V+ Wire: Yellow/Green == 5 Radio Switched 12V+ Wire: Purple == 4 Radio Ground Wire: Chassis == 6 Radio Illumination Wire: Red/Blue == NON Antenna Trigger Wire: Green/White == Antenna Power Antenna Wire: Green == 2 Front Speaker Size: n/a Front Speaker Location: n/a Left Front Speaker Wire (+): Blue/White == 16 Left Front Speaker Wire (-): Blue/Red == 15 Right Front Speaker Wire (+): White/Black == 9 Right Front Speaker Wire (-): Blue/Black == 10 Rear Speaker Size: n/a Rear Speaker Location: n/a Left Rear Speaker Wire (+): Green/Yellow == 13 Left Rear Speaker Wire (-): Black/Yellow == 14 Right Rear Speaker Wire (+): Blue == 12 Right Rear Speaker Wire (-): Red == 11
- Q: Is it possible for a wire to arc with a nail? The u-nail that hangs the wire to a wooden support beam looks like it was hammered in too far and may have cut through the insulation around the wire. Is this a fire hazard or can I leave it as is?
- Electricity moves very similar to water it will always find the path of least resistance. So yes if you cut into the wire you will energize the u-nail. Your best plan is to remove the nail carefully while there is no power in the circuit examine the wire and if there is a cut through the insulation replace the wire. I say this because from your question it sounds like you are in the electrical rough in stage. You can install a J Box there but by code it must be accessible so that would mean there would be constant reminder of the problem in the wall.
- Q: I have a 200 amp main breaker just below my meter, which is mounted on a pole. The neutral wire coming in is run to ground. From this box, I've run 2 cables (1/0) ~80 ft to another box with a 150 amp main breaker. This box is grounded to an 8ft ground rod. I am wondering whether this setup (no neutral wire from meter pole to building) would potentially allow a ground fault without tripping the 200 amp main. For example, if somebody dug into the line with a backhoe? Oh yeah, the cable is in a 3ft deep trench that will be covered. I have an abridged version of the NEC, but I haven't found this particular topic covered. Thanks.
- Good job, Amy. I'll bet you didn't post a question here similar to: Waz the difference between nuetral and ground. I nned to now this for my electian exam tomorow.
- Q: True or False?Branch wiring from a 200A - 3 phase 4 wire panelboard.WIRE #PHASES 1 --- PHASE A 2 --- PHASE B 3 --- PHASE C 4 --- NEUTRAL - WHITE WIRE 5 --- PHASE A 6 --- PHASE B 7 --- PHASE C 8 --- NEUTRAL 9 --- GROUNDTOTAL OF 9 WIRES GOING TO SIX (6) 20A 120V CIRCUITS
- False! If you had 6 120v circuits each circuit has 1 phase, 1 neutral conductor and 1 ground conductor for a total of 3 wires per circuit. 6 circuits times 3 conductors equals 18 wires. You don't use the same neutral conductor for different phases but you can if they are the same phase provided you don't go over the maximum allowed current rating for that wire and insulation.
Send your message to us
Hot Dip Galvanized Steel Wire For Gabion
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords