• Carbon Steel  Wire Rod System 1
  • Carbon Steel  Wire Rod System 2
  • Carbon Steel  Wire Rod System 3
Carbon Steel  Wire Rod

Carbon Steel Wire Rod

Ref Price:
get latest price
Loading Port:
XINGANG PORT,China
Payment Terms:
TT or LC
Min Order Qty:
25 Tons m.t.
Supply Capability:
100,000 Tons per Month m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications of Carbon Steel Wire Rod:

Steel Grade: Q195/235, SAE1006-1018B   Standard: ASTM, GB

Diameter: 5.5mm, 6.5mm, 7mm,8mm,9mm,10mm,12mm,14mm 

Diameter tolerance: ±0.3mm   Type: in coil, coil weight around 2MT  

Technique: Hot Rolled    Place of Origin: China Mainland

Surface: round, no twisted, light and smooth       Brand Name: HSKY         

Chemical Composition: (Please kindly find our chemistry of our material based on Q195、Q235A and Q235B as below for your information)

Trademark

Rank

Chemical composition (quality score) %  

C

Si

Mn

S

P

 

 

Q195

 

0.06-0.12

0.30

0.25

0.050

0.045

Q235

A

0.14-0.22

0.30

0.30-0.65

0.050

0.045

Q235

B

0.12-0.20

0.30

0.30-0.70

0.045

0.045

 Trademark

 Rank

Pulling Test

Bend PointΔs/Mpa 

 Tensile Strength

Elongation Ratioδ5%

Thickness (Diameter) /MM

Thickness (Diameter) /MM

≤16

16-40

≤16

16-40

Q195

 

195

185

315-390

33

32

Q235

A

235

225

375-500

26

25

Q235

B

235

225

375-500

26

25

 

Usage and Applications of Carbon Steel Wire Rod:

After hot-rolled the products shaped into coil and delivery as finished product, including round, square, rectangular, hexagonal and so on. Since most of the products are round, it is generally called wire rod. Carbon steel wire rod is widely used in construction and manufacturing. Carbon steel wire rod is mainly used for reinforcement of reinforced concrete and welded structure or reprocessed (roberts , nail, etc.) materials, especially used to produce wire drawing, welding electrode, nails,  spring, electronic,  precise machinery parts  and so on.

Packaging & Delivery of Carbon Steel Wire Rod:

Packaging Detail: products are packed in coil, each coil weight around 2 MT, and then shipped by container or bulk vessel

Delivery Detail: within 45 days after received deposit or LC.

Label: to be specified by customer, generally, each bundle has 1-2 labels

Trade terms: FOB, CFR, CIF

 

Carbon Steel Wire Rod on Port

 wire rod on port

 

Carbon Steel Wire Rod in Container

 

 wire rod in container

 

Note:

1. Our products are produced according to national standard (GB), if not, supply according to national standards (GB) or agreement as customer required.

2. Other Grade and Standard carbon steel wire rod we can supply:

Grade:H08A, 30MnSi, 62B-82B

Standard: AISI, BS, JIS, DIN

The Minimum Order Quantity of these products is high, and need to be confirmed.

3. We can not only supply carbon steel wire rod; if you need anything about building materials, please contact us.

4. Please send us your detail specifications when inquire. We will reply to you as soon as possible.We sincerely hope we can establish a long stable business relationship.

Q: i hate the wired controllers. they all get tangled
Not all. theres some wireless controllers out on the stores i recommend using a logitech wireless controller
Q: Got a new kenwood stereo to replace the old kenwood one in my VW polo 1998. Workes fine but when I pushed the stereo into my dashboard a wire came out so I pulled it out and put it back in. It worked, but next morning my car battery was near dead, I unplugged the stereo and its fine now. I assume I used wrong wire? Does anyone have a diagram or picture of how it should be wired?
When you wired it did you butcher the wires or use a wiring harness? With the wiring harness, everything is labeled and color coded. Match colors to the kenwood wiring harness, splice or use butt connectors, plug harness into factory harness and player, attach antenna wire and you're done! If you did butcher the wires and left enough wire, repair the harness and buy a harness kit at your local sound shop, really cheap too! Good luck!
Q: I'm cutting 18 gauge wire, so I can run valve wires to the timer in the garage. The plastic casing over the wire is pretty thick, so I had to squeeze hard. I accidentally cut into the color casing of the actual wire inside, so I want to start over. How can I cut this wire away, and start again?
Use a utility knife and cut around the casing then strip it off. Or run out to Home Depot and get yourself a wire cutter stripper tool.
Q: let me start off with I am not an electrician I just do basic stuff for side work I came in the project at the end. The lady wanted me to wire in 6 receptacles, a light switch and light fixture all on one circuit. everything is good except for the receptacle at the start of the circuit it has the lead/ hot coming in the power to the other receptacles going out and the power to the light going out (3 groups, 9 wires total). normally I would have used a junction box but I didn't pull the wire. How can I wire this. Would a 15 amp receptacle work?
A 15 Amp receptacle will work, of course, but the receptacle box is most likely already overfilled. So in order to keep the wire count down, your best way to go is to buy a receptacle that uses screw down connector tabs. (NOT the kind that you have to put the wire under the screw, but the kind that you insert the wire into the back and then turn the screw down to clamp onto it!) The receptacle is a little more money but it would be worth the expense to make this hook up work. Hot wire (Black): Connect all three black wires to the back of the receptacle on the brass colored screws. Common wire (White): Connect all three white wires to the back of the receptacle on the silver colored screw. Ground: make a short pigtail of bare copper wire (about 6 or 7 inches long). Then connect the pigtail to the other 3 bare copper ground wires using a wire nut. Then connect the other end of the pigtail to the grounding connection of the receptacle. MAKE SURE THE POWER IS OFF WHEN YOU DO ALL OF THIS SO THAT YOU CAN LIVE TO TELL THE TALE! :-)
Q: What's the use of the live wire,neautral wire and earth wire in a plug? The purpose
Earthing Wire
Q: I was looking at the wiring of my current thermostat and I want to know why it's wired the way it is...The yellow wire was wrapped around the white terminal and the yellow terminal. And the white wire was wrapped the around the Orange terminal. The red and green wires were each wrapped around their respective terminals. And the blue wire wasn't connected to anything. Why would the electrician have wrapped the yellow wire around 2 terminals? Is that normal? Also, I tried installing a new thermostat but the heating is not working. The fan works but it just blows room temperature air. The new thermostat only had 4 terminals for R, Y, W, G. I connected the wires I had to their respective terminals. However, I think it may not be working because I have a probably have a heat pump. Any Ideas why else it might not be working? Thanks a lot!
Yeah it sounds like you have a heat pump and it is wired VERY basically. Your new thermostat will not work because it has no O terminal. You will have to buy a heat pump t-stat then wire it the same way your old one was and it should work fine. In other words Red to R and Rh if it has one, Green to G, Yellow to Y *AND* W, and White to O. Basically what's being done the way your old t-stat was wired is the compressor is being brought on in heat or cool and the white wire on O is switching your reversing valve for cooling mode. The way you have the new one wired is just going to switch the reversing valve and turn the fan on and won't bring the compressor on when the heat is called to run. If your system has backup heat, that extra blue wire could be used to bring the backup heat on if it is re-wired to do so. If your going to have it re-wired I would change the wiring so blue was the reversing valve and white was the backup heat. This would require re-wiring both indoor and outdoor units if it is a split system or re-wiring the package unit if it is that type. Or if you really want it done right have new thermostat wiring run and have it wired properly for a heat pump. If you don't want to go through all of that just buy a heat pump stat and wire it like your old stat.
Q: Help me, please! I have an old air conditioning system...made in 1985, and the condenser fan went out. Long story short, I bought a new fan and I don't know how to hook it up. The old fan had 4 wires coming out of it: purple, black, green, and brown. The green is the ground and the brown and the purple went to the capacitor, black to power. Then there were two smaller black wires attached to the capacitor and they lead out to other components. My new fan has a green wire, a white wire, a black wire, a brown wire and a brown and white striped wire. My problem is this: I don't know where to attach the white wire or what to do with the two smaller black wires that were attached to the old capacitor. I was told by the gentleman who sold me the fan that I splice the white wire to purple wire - then do I hook that to the capacitor? What do I do with the two smaller black wires that lead out to other components??? (Cap them off???) I am confused and need some advice!
I suggest having a tech. wire it in for you, but your new motor should be wired this way, the black and white are your hot and common, so 208v unit, hook black wire to L1, white wire to L2, green is a ground, ground it to cabinet somewhere, brown goes to one side of run cap, brown/white goes to other side of run cap. if you are unsure about how to swap it out then seek someone with some electrical background or an hvac tech., dont hurt yourself or your equipment by doing it improperly, good luck with it!
Q: I have looked up wires for this car but the ones that I have looked up tell me i should have different colored wires. These are the wire colors i have:yellowyellow/blackorangepurple/whitewhiteblue/redgreen/blackpink/blackred/blackblue/orangeyellow/redwhite/redgreen/orangePlease Please Please help me!Thanks,Ash
1998 Mazda Protege Lx
Q: I need thick floral wire and they keep saying things like 24 gauge 26 gauge 28 gauge.. like how would i know which one is thiickest if i'm buying it online.
Floral Wire Gauge
Q: what wires connect from the vehicle to the a/f sensor
Why do u want to know what wires go to the sensor? If you have a code for the a/f sensor..99 % of the time it is an open in the sensor itself. On rare occasion there are others like a chewed wire by a rodent. But I would just recommend replacing the a/f sensor. And i u were to follow the wires from the male connector they would lead you to a big wire harness that basically just all ends up at the ECU. Just in case u wanted to know.
HSKY is the member of China Iron and Steel Association,our main product is strip steel, H beam and wire rod. We also can produce the billet which is our material for the other product. The annual production capacity of steel product is 3.5 million tons. We devote oneself to provide the customers superem cost performance product and good service.

1. Manufacturer Overview

Location Tangshan, China
Year Established 2003
Annual Output Value Above US$ 750 Million
Main Markets Middle East; Southeast Asia; east asia; Africa
Company Certifications ISO 9001;ISO 14001;OHSAS 18001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Tianjin;
Export Percentage 50% - 70%
No.of Employees in Trade Department 21-30 People
Language Spoken: English; Chinese
b) Factory Information
Factory Size: Above 1,500,000 square meters
No. of Production Lines 5
Contract Manufacturing OEM servise offered
Product Price Range average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords