• Wire Rod Q195 System 1
  • Wire Rod Q195 System 2
  • Wire Rod Q195 System 3
Wire Rod Q195

Wire Rod Q195

Ref Price:
get latest price
Loading Port:
XINGANG PORT,China
Payment Terms:
TT or LC
Min Order Qty:
25 Tons m.t.
Supply Capability:
100,000 Tons Per Month m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications of Wire Rod Q195:

Steel Grade: Q195      Standard: ASTM, GB

Diameter: 5.5mm, 6.5mm, 7mm,8mm,9mm,10mm,12mm,14mm 

6.5mm can be drawing into 2mm/8.0mm can be drawing into 3mm 

Type: Drawn Wire in Coil, each coil weight about 2MT      

Brand Name: N-RIVER   Place of Origin: Hebei, China

Chemical Composition:

Please kindly find our chemistry of our material based on Q195 as below for your information

 

Trademark

Rank

Chemical composition (quality score) %  

C

Si

Mn

S

P

 

 

Q195

 

0.06-0.12

0.30

0.25

0.050

0.045

 Trademark

 Rank

Pulling Test

Bend PointΔs/Mpa 

 Tensile Strength

Elongation Ratioδ5%

Thickness (Diameter) /MM

Thickness (Diameter) /MM

≤16

16-40

≤16

16-40

Q195

 

195

185

315-390

33

32

 

Usage and Applications of Wire Rod Q195:

After hot-rolled the products shaped into coil and delivery as finished product, including round, square, rectangular, hexagonal and so on. Since most of the products are round, it is generally called wire rod. Carbon steel wire rod is widely used in construction and manufacturing. Carbon steel wire rod is mainly used for reinforcement of reinforced concrete and welded structure or reprocessed (roberts , nail, etc.) materials, especially used to produce wire drawing, welding electrode, nails,  spring, electronic,  precise machinery parts  and so on.

 

Production Process of Wire Rod Q195:

 

Steel billet---Heating---Rolling---Water-cooling---Coiling---Cooling---Inspection---Bundling---Exworks

 

Packaging & Delivery of Wire Rod Q195:

Packaging Detail: products are packed in coil and then shipped by container or bulk vessel

Each coil weight: 2-3MT

Delivery Detail: within 45 days after received deposit or LC.

Label: to be specified by customer, generally, each bundle has 1-2 labels

Trade terms: FOB, CFR, CIF

 

Wire Rod in Bulk Vessel

 

 WIRE ROD IN CONTAINER

 

Wire Rod in Container

 WIRE ROD IN BULK VESSEL

 

Note:

1. Our products are produced according to national standard (GB), if not, supply according to national standards (GB) or agreement as customer required.

2. Other Grade and Standard carbon steel wire rod we can supply:

    Grade: H08A, 30MnSi, 62B-82B

    Standard: AISI, BS, JIS, DIN

    The Minimum Order Quantity of these products is high, and need to be confirmed.

3. We can not only supply carbon steel wire rod; if you need anything about building materials, please contact us.

4. Please send us your detail specifications when inquire. We will reply to you as soon as possible. We sincerely hope we can establish a long stable business relationship.

 

Q: Basically I have a 3000watt amp, and I need to buy the right wires. Would I still manage to get the full power out of the amplifier with 1000w speaker wiring kit or do I need to buy a 3000w speaker wiring kit?If so, where is the difference with the higher wattage wiring kits.Thanks
Wire okorder with free shipping Goodluck
Q: im assuming red to red and black to black? but then what about the extra green and white wires in the iphone cable? where do they go?
Never assume anything. Wire colours in such cables are not necessarily assigned according to a standard pattern. Before you proceed, find printed documentation -- or its online equivalent -- that clearly and definitively shows the functions of the wires by colour. If all of the wires are for audio (which is possible, but not certain), don't connect any sort of power source to any of them. If it is a USB cable, the red and black are power wires, and the green and white are for digital data. A question was posted about USB wire colours on Y!A about 3 years ago (USB wire color code, please help?). The best answer contains enough info to help you.
Q: I have 2 connectionswire and wireless,im only connected to my wire how do I open a connection to my wireless?
You first need to make sure that your computer has support for wireless(WLAN). If it doesn't then you can't connect to the wireless network. If you do have a wireless network card then you shoudl be able to click on the start menu and go connect to and then wireless networks. It can sometimes be found in the task bar on the bottom right of your screen
Q: I'm trying to tighten the electrical wires on my car.Do I just use pliers and twist them tighter?Can I use my hands?-tightening the wires on my ignition switch and starterNeed to know asapNo B.S. just need to know how
I think that twisting with a pair of pliers is best, less chance of getting a nasty metal splinter in your skin.
Q: Ceiling fan has Green, Blue, black and white and the ceiling only has a black wire and white wire.
Do what Elaine said above. If there is not a light, don't use the blue wire. If there isn't a green wire or bare wire in your box, attach the fan's green wire to the electrical box itself (if its metal.).
Q: I was looking at the wiring of my current thermostat and I want to know why it's wired the way it is...The yellow wire was wrapped around the white terminal and the yellow terminal. And the white wire was wrapped the around the Orange terminal. The red and green wires were each wrapped around their respective terminals. And the blue wire wasn't connected to anything. Why would the electrician have wrapped the yellow wire around 2 terminals? Is that normal? Also, I tried installing a new thermostat but the heating is not working. The fan works but it just blows room temperature air. The new thermostat only had 4 terminals for R, Y, W, G. I connected the wires I had to their respective terminals. However, I think it may not be working because I have a probably have a heat pump. Any Ideas why else it might not be working? Thanks a lot!
Yeah it sounds like you have a heat pump and it is wired VERY basically. Your new thermostat will not work because it has no O terminal. You will have to buy a heat pump t-stat then wire it the same way your old one was and it should work fine. In other words Red to R and Rh if it has one, Green to G, Yellow to Y *AND* W, and White to O. Basically what's being done the way your old t-stat was wired is the compressor is being brought on in heat or cool and the white wire on O is switching your reversing valve for cooling mode. The way you have the new one wired is just going to switch the reversing valve and turn the fan on and won't bring the compressor on when the heat is called to run. If your system has backup heat, that extra blue wire could be used to bring the backup heat on if it is re-wired to do so. If your going to have it re-wired I would change the wiring so blue was the reversing valve and white was the backup heat. This would require re-wiring both indoor and outdoor units if it is a split system or re-wiring the package unit if it is that type. Or if you really want it done right have new thermostat wiring run and have it wired properly for a heat pump. If you don't want to go through all of that just buy a heat pump stat and wire it like your old stat.
Q: hey im wiring up a headunit to my L300 van. The factory headunit wasnt there and im having trouble connecting which colour wires to the factory colour wires. if anyone knows which coulours go to what would be much appreciatedcheers.
Hi, okorder /
Q: sence my stock head unit has no remote wire, when I hook the amp up, will it still drain the battery? I have everything connected, but the deck does not have no remote wire, and if it does I have no idea how to locate it. I am worried it will continue to run the amp when the car is off and drain the battery. Am I worried for nothing? If it will continue to drain the battery, how do I prevent this from happening?
use a test light ($5), you just need to connect the remote wire to a wire that is only hot when the car is on, (like the ignition power wire -not constant- going to the radio) and on factory radios it is usually a wire that is made to send the signal to the power antenna
Q: On a seat switch on a poulan mower it has three wires are two of them grounds or one.
It's probably one positive, one negative and one earth ground.
Q: 6000+ heat sinc wires?i up graded my cpu and the new heat sinc has a 4 wire conector and my old 3800+ heat sinc has 3 and mobo has 3 pin processor works great. sys recognizes amd 6000+ dual core processor @ 3.0 ghz but not the model #???? sys works great scored 10143 on 3DMARK 06 anyway the fan and temp s are all good any ideas what the other wire is
Yes, the fan on your heat sink has a fourth wire that..............(tune back in tommorrow folks, for the conclusion), (sorry, somebody's telling jokes over here!) The fourth wire is a Speed control wire. The first wire,(Red), is 12VDC,(power), the second,(Black), is the ground, should be a Blue wire, for rpm sensor, and the fourth,(color codes vary), is the wire that the BIOS uses to speed the fan up when the temp of the cpu raises, slows the fan down, when it isn't used as hard. Temp of the cpu, is found through one of it's pins on the bottom of it.
N-RIVER,a well-known enterprise specializing in the production and sales of wire rod, the annual capacity of the wire rod is 5.6 million mtons.The mian product is high speed wire Φ5.5mm-Φ19mm, the ecnomic and technical norms is living in the same industry advanced level of domestic. Since the establishment of our company, we have been aimed to provide our customers qualified products and good service.

1. Manufacturer Overview

Location Qianan, China
Year Established 2002
Annual Output Value Above US$ 2,500 Million
Main Markets America, Japan, England, Germany, Korea, South Aisa and Southeast Aisa
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Tianjin
Export Percentage 60% - 70%
No.of Employees in Trade Department 21-30 People
Language Spoken: English; Chinese
b) Factory Information
Factory Size: Above 900,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered;
Product Price Range High; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords