• Wire Rod Q195 System 1
  • Wire Rod Q195 System 2
  • Wire Rod Q195 System 3
Wire Rod Q195

Wire Rod Q195

Ref Price:
get latest price
Loading Port:
XINGANG PORT,China
Payment Terms:
TT or LC
Min Order Qty:
25 Tons m.t.
Supply Capability:
100,000 Tons Per Month m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications of Wire Rod Q195:

Steel Grade: Q195      Standard: ASTM, GB

Diameter: 5.5mm, 6.5mm, 7mm,8mm,9mm,10mm,12mm,14mm 

6.5mm can be drawing into 2mm/8.0mm can be drawing into 3mm 

Type: Drawn Wire in Coil, each coil weight about 2MT      

Brand Name: N-RIVER   Place of Origin: Hebei, China

Chemical Composition:

Please kindly find our chemistry of our material based on Q195 as below for your information

 

Trademark

Rank

Chemical composition (quality score) %  

C

Si

Mn

S

P

 

 

Q195

 

0.06-0.12

0.30

0.25

0.050

0.045

 Trademark

 Rank

Pulling Test

Bend PointΔs/Mpa 

 Tensile Strength

Elongation Ratioδ5%

Thickness (Diameter) /MM

Thickness (Diameter) /MM

≤16

16-40

≤16

16-40

Q195

 

195

185

315-390

33

32

 

Usage and Applications of Wire Rod Q195:

After hot-rolled the products shaped into coil and delivery as finished product, including round, square, rectangular, hexagonal and so on. Since most of the products are round, it is generally called wire rod. Carbon steel wire rod is widely used in construction and manufacturing. Carbon steel wire rod is mainly used for reinforcement of reinforced concrete and welded structure or reprocessed (roberts , nail, etc.) materials, especially used to produce wire drawing, welding electrode, nails,  spring, electronic,  precise machinery parts  and so on.

 

Production Process of Wire Rod Q195:

 

Steel billet---Heating---Rolling---Water-cooling---Coiling---Cooling---Inspection---Bundling---Exworks

 

Packaging & Delivery of Wire Rod Q195:

Packaging Detail: products are packed in coil and then shipped by container or bulk vessel

Each coil weight: 2-3MT

Delivery Detail: within 45 days after received deposit or LC.

Label: to be specified by customer, generally, each bundle has 1-2 labels

Trade terms: FOB, CFR, CIF

 

Wire Rod in Bulk Vessel

 

 WIRE ROD IN CONTAINER

 

Wire Rod in Container

 WIRE ROD IN BULK VESSEL

 

Note:

1. Our products are produced according to national standard (GB), if not, supply according to national standards (GB) or agreement as customer required.

2. Other Grade and Standard carbon steel wire rod we can supply:

    Grade: H08A, 30MnSi, 62B-82B

    Standard: AISI, BS, JIS, DIN

    The Minimum Order Quantity of these products is high, and need to be confirmed.

3. We can not only supply carbon steel wire rod; if you need anything about building materials, please contact us.

4. Please send us your detail specifications when inquire. We will reply to you as soon as possible. We sincerely hope we can establish a long stable business relationship.

 

Q: i need to know what color the wires are to hook up a stereo in my friends truck. her factory radio was stolen and they stole the factory plug
This Site Might Help You. RE: 98 dodge dakota stereo wiring diagram, what are the speaker wire colors? i need to know what color the wires are to hook up a stereo in my friends truck. her factory radio was stolen and they stole the factory plug
Q: What is the best brand of wire to use for getting power to my amp?
Need info on the amp to make that call. ONe thing is for sure monster cable is a huge rip off and 10 gauge wire is not thick enough for an amp power cable. For around 800 watts or less 8 gauge will be good enough. The thicker the wire the better the performance. Almost all wire is essentially the same, its the gauge that is important. (0 is thickest, 10 thinner, 20 even thinner etc.) Good Luck
Q: I was re-wiring a light switch and a fan control knob and I accidentally cut a wire too short. This wire comes out the front of the fan dial and goes around to the back, connecting to another wire, thus placing a wire nut impossible. Can I just link the two ends together, then seal it with electrical tape? Or do I have to buy a new fan dial (which will cost $25, a cost I'm trying to avoid)? Will just the tape be safe enough?
You should go to Home Depot or an electric store and get some beans to connect them. The associate will tell you how to connect them. Or just youtube, 'beaning electric wire'
Q: Two wires are placed parallel to each other. What would be the effect of passinga) upward current through both wiresb) an upward current throgh one wire and a downward current through the other.Explain.
a) When the currents through both the wires are in the same direction, the magnetic field due to each midway between them, by right-hand thumb rule, will be in opposite directions. This will result in attraction between the wires. b) When the currents through both the wires are in the opposite directions, the magnetic field due to each midway between them, by right-hand thumb rule, will be in the same direction. This will result in respulsion between the wires.
Q: From my ceiling fan I have the following wires: green, white, blue and blackFrom my ceiling I have a bunch of wire in each of these colours: brown, red and orange.Which wires do I connect with each other??
These are all probably hot-side wires. If you have the knowledge and the tools, find out which wire or wires is/are hot in the box with the switch off. If you have no idea what I am talking about, you REALLY need to find someone who knows electricity. BTW, the wires in the fan are quite simple to decode. The green wire is the ground and attaches to either the box or a ground wire in the box. The white wire is the neutral and attaches to the white wires in the box. The black is the hot lead for the fan and the blue is the hot lead for the light. These two can be combined if you have only one wall switch. Where they attach in the box will be determined by which hot lead is switched. I can probably guess how the box and switch are wired but I may be wrong and that would be dangerous. Call an electrician so you don't burn your house down.
Q: I had gotten 5 commercial solar cells from siliconsolar. But, I need to know where could I get wires to connect to the solar cells, in order to harness the cells energy.
Wire is wire. Use wire heavy enough to handle the current and good enough insulation to handle the outdoors conditions.
Q: what to do if i unhooked my starter without unhooking my battery and the hot and gound wire caught on fire
Replace the cables, and chalk it up as a learning experience. Now you know why shops charge so much. They learn before doing.
Q: Is it possible for a wire to arc with a nail? The u-nail that hangs the wire to a wooden support beam looks like it was hammered in too far and may have cut through the insulation around the wire. Is this a fire hazard or can I leave it as is?
Hello, anytime the insulation is broken on the line it can be a potential fire hazard, and yes they can arc or short out. The potential may not be large but with fire it safer to err on the side of caution. Codes vary around the country so check there, but we typically pull the staple and determine how deeply the insulation is really compromised, if it is only through the external shielding an in-expensive way to safely repair it is with a shrink tube type of product. However, if any of the internal strands have been compromised the line would need to be cut and a junction box installed and the wire spliced back together inside the box. Hope this helps:-)
Q: I needed a new tail light for my trailer. The aftermarket tail lights only came with two wires sticking out the back, one red and one black. The stock tail light that broke had 3 wires and so does the harness on the trailer end. People have told me that even though it is different it will work. Do I join the two hot wires together with the red wire and then the return wire to the black? There is no wiring diagram avalible and I dont have the money to replace then entire lighting system. Thanks for your help.
Pull the lens and look at the bulb. If it is a 2 element bulb then it will work, if it is a single element it will not. If it is a 2 element then one of the wires is turn and stop light and the other is tail light. It will use a body ground in that case. On your trailer harness you will have a brown wire, that is tail lights, the turn and stop light (same wire) will be either green or yellow depending on what side of the trailer you are on. The white wire is ground. The turn and stop light will be much brighter than the tail light so just twist the wires together and see which is which. You can hook the white wire to the mounting screw of the light fixture to be sure you have a good ground.
Q: Two current-carrying wires are lying right on top of each (at a right angle) other, with currents flowing in the wires in the directions pointing up for the vertical wire and to the right for the horizontal wire. The horizontal wire is fixed and does not move. What happens to the vertical wire?Choices:It moves out of the pageIt rotates clockwiseIt rotates counter-clockwiseIt moves to the leftIt moves to the rightIt moves into the page
The vertical wire rotates (clockwise ?) Draw the situation where you are looking directly at the 'end' or the horizontal wire with the current coming towards you .. the magnetic field from this current is a set of concentric circles with counter- clockwise direction (using the screw-cap rule.. turn counter-clockwise to move cap towards you as it loosens). Now place the vertical wire in this field (close to horizontal wire) and apply Fleming's left-hand motor rule to find the direction of force/motion for the upward current. Above the horiz wire .. Field (first finger) points left, Current upwards (second finger), Motion/force (thumb) direction is towards you. Below the horiz wire .. Field right, Current upwards, Motion/force (thumb) direction is away from you. Seen from the side this gives the vertical wire a rotation in the vertical plane .. which way depends on which side you view it from. ('conventional' viewing would give a clockwise rotation)
N-RIVER,a well-known enterprise specializing in the production and sales of wire rod, the annual capacity of the wire rod is 5.6 million mtons.The mian product is high speed wire Φ5.5mm-Φ19mm, the ecnomic and technical norms is living in the same industry advanced level of domestic. Since the establishment of our company, we have been aimed to provide our customers qualified products and good service.

1. Manufacturer Overview

Location Qianan, China
Year Established 2002
Annual Output Value Above US$ 2,500 Million
Main Markets America, Japan, England, Germany, Korea, South Aisa and Southeast Aisa
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Tianjin
Export Percentage 60% - 70%
No.of Employees in Trade Department 21-30 People
Language Spoken: English; Chinese
b) Factory Information
Factory Size: Above 900,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered;
Product Price Range High; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords