Description of Quick Link Bale Tie Wire

 

1. Material:

Cotton pack wire, bale wire with single loop processing with low carbon steel wire, through drawing and electric galvanizing or hot dipped galvanizing or annealed.

 

2. Standard wire gauge:

2.00 to 4.50mm

 

3. Length:

2 to 8m 

 

4. Tensile strength:

35 to 60kg/mm, according to customers' requests

 

5. Packing:

100-125 pcs/bundle, then in wooden case or straight in bundles 

 

6. Usage:

for tying cotton, plastic, paper, and so on .

 

7. Popular Sizes:

Model

Number

Diameter

  (mm)

    Tensile Strength

(kg/square mili meter)

Elongation

     (≥)

    Coil

   (inch)

Zinc coating

Coil Weight

    (kg)

6#

4.60-4.95

         40-70

15%

18,20

30-260

300-800

7#

4.25-4.60

         40-70

15%

18,20

30-260

300-800

8#

3.90-4.25

         40-70

15%

18,20

30-260

300-800

9#

3.65-3.90

         40-70

15%

13,18,20

30-260

300-800

9.5#

3.49-3.65

         40-70

15%

13,18,20

30-260

300-800

10#

3.32-3.49

         40-70

15%

13,18,20

30-260

300-800

10.5#

3.14-3.32

         40-70

15%

13,18,20

30-260

300-800

11#

2.96-3.14

         40-70

15%

13,18,20

30-260

300-800

11.5#

2.84-2.96

         40-70

15%

13,18,20

30-260

300-800

12#

2.70-2.84

         40-70

15%

13,18,20

30-260

300-800

12.5#

2.50-2.70

         40-70

15%

13,18,20

30-260

300-800

13#

2.32-2.50

         40-70

15%

13,18,20

30-260

300-800

13.5#

2.18-2.32

         40-70

15%

13,18,20

30-260

300-800

14#

2.03-2.18

         40-70

15%

13,18,20

30-260

300-800

14.5#

1.90-2.03

         40-70

12%

13,18,20

30-200

300-800

15#

1.76-1.90

         40-70

12%

13,18,20

30-200

300-800

16#

1.61-1.70

         40-60

12%

13,18,20

20-60

300-800

16.5#

1.52-1.61

         40-60

12%

13,18,20

20-60

300-800

17#

1.43-1.52

         40-60

12%

13,14,18

20-55

200-350

17.5#

1.30-1.43

         40-55

12%

13,14,18

20-45

200-350

18#

1.19-1.30

         40-55

12%

11,12,13

20-45

25-350

18.5#

1.11-1.19

         40-55

12%

11,12,13

20-45

25-350

19#

1.02-1.11

         40-55

12%

11,12,13

20-45

25-350

19.5#

0.93-1.02

         35-55

12%

11,12,13

20-45

25-350

20#

0.84-0.93

         35-55

12%

11,12,13

20-45

25-350

21#

0.76-0.84

         35-55

12%

11,12,13

20-40

25-350

22#

0.67-0.76

         35-55

12%

11,12,13

20-40

25-350

22#

0.62-0.67

         35-55

12%

11,12,13

20-40

25-350

8. How to Use?

Simply snap the ends together by hand ... pull the loops together to form a

"figure 8" - and the tie is complete.

 

 How to use

Packing

 Packing

Delivery

 delivery

Q:Coming from my ceiling I have a black, a grey, 2 white, 2 bare and a red wire. Coming from my ceiling fan/light fixture is a green, black, black with a white stripe and a white wire. How exactly would I go about wiring this? It is a two switch setup without a remote.Thank you in advance.
Call the manufacturer about your ceiling fan. It may be designed to work with a light kit. I've done this myself. The grey and red sound like wiring that works with the light kit. The black, white, and green wires are hook to your house wire. (House wire is black, white, and bare (ground)).
Q:What exactly is 6 AWG stranded grounding wire usually used for?
To connect parts of the electrical system that you want to stay very near Earth potential to the actual Earth. They carry lightning strike current to the Earth if the electrical system is struck. Ground wires and grounding electrodes metal stakes driven into the Earth they connect to) keep the exposed metal parts of appliances safely close to Earth potential when there is an insulation failure inside the appliance that connects those parts to the the hot side of the circuit. The ground path resistance has to be low to soak up this fault current while keeping the appliance case voltage below about 50 volts (above which you might get a serious shock) until a protective device (fuse, circuit breaker or ground fault breaker) opens the hot line. So its main purposes are lightning protection and shock prevention. -- Regards, John Popelish
Q:what gauge wires should i use for my 12'' alpine typr r SWR-1242D?
For the speaker wire going from the amp to the speaker? Try to stay above 16 gauge, I use 12 gauge as over-kill. It costs like 12 cents more per foot and is completely worth it. For the power wire going from the battery to the amp? Use no thinner than 4 gauge power and ground wire assuming your only pushing a single Type-R. Good Luck!
Q:My starter I replaced has 3 wires, two red and one black. Where does each wire go? Pictures would be very helpful if possible
The First red wire goes to the solenoid on the fender well right by the battery. the second red wire goes from the solenoid to the starter on the one main post there. the black wire goes from the engine block to the battery on the negative side. All connections must be tight but not not crushing on the battery
Q:How do you wire a 2 wire smoke detector directly to an alarm (no panel). The terminals are numbered 1,2,3,4 and the instructions say that 1 is for DC+ and 2 is for DC-. How do I wire an alarm so when the detector senses smoke, the alarm goes off? Thank you.
you would have to have a dc transformer, but what it appears that is to be wired into a home sec system. I may be wrong what is 3/4 for?
Q:I am changing an outside light with a inside wall switch there is 2 cables going to the outside box. ( 3 wires -white w/red line wire and black wire and green ground wire ) other cable 3 wires is white wire and black wire and green ground wire.On the inside switch is 3 wires white wire a black wire a green ground wire.for some reason it is not working, can any one tell me how to wire and or test for power. thank you
I changed my outside light and sounds like the wires were similar to yours. Make sure you have the power turned off. And, connect and twist the wires (same colored) together, and use the caps, and connect the green ground wire and turn on the power to test it again. Might want someone near the power switch and someone to watch the light to make sure sparks don't fly. And, make sure you have a bulb that works in there. Otherwise might want to contact someone knowledgeable (family member/electrician) with help.
Q:but it says there are three Pink wires. There's not even three pink wires coming out of the car.The chassis/clip has been removed (by previous owner) and all that is left is the wires. All that is needed is a list of the colors and what they go to. Thanks.
Wiring okorder /
Q:home, thermostat, wiring
The standard wiring for Heat/Cool T-stat. Is as follows Red 24 volts to the T-stat. White to the heat. Green to the fan relay. Yellow to the condenser.
Q:i heard there are many diferent copper wire but i only know 2 kinds.1 is for eletric and the other is for crafts.So what else is there?
Copper wire for electric/electronic cables has lots of categories, such as solid, stranded, coaxial, ribbon, power, small signal, stripline, flexible, twisted pair, and others. But your division into crafts/electric is not too useful, as either type of wire can be used for the other. You can use electric wire for crafts and vv. You can also get copper wire for construction use. .
Q:when u first get braces do they put the bands and the wire or just the bands cuz im getting them monday
You get the brackets with bands and the wire. Rubber bands, though, come later.
FOREVER 2012l,a well-known in manufacturing various kinds of chain link mesh, hexagonal wire netting, welded wire mesh, pvc wire .All our products are backed by our Quality Management system which has been approved and accredited by the CQC to ISO.

1. Manufacturer Overview

Location Hebei, China
Year Established 1988
Annual Output Value Above US$ 20 Million
Main Markets Mid East; Eastern Europe; North America; America; Europ; Local selling to trade company.
Company Certifications ISO 9001:2008;CE;

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Tianjin
Export Percentage 30% - 40%
No.of Employees in Trade Department 200 People
Language Spoken: English; Chinese;
b)Factory Information  
Factory Size: Above 30,000 square meters
No. of Production Lines Above 5 producce line, 120 units machine
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range reasonable ; Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords