Horizontal Axial/Mixed Flow Water Pump for Irrigation
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Horizontal Axial/Mixed Flow Water Pump for Irrigation
1.Structure of Horizontal Axial/Mixed Flow Water Pump for Irrigation Description
HW Axial/Mixed-flow pump is a horizontal pump,It is driven by diesel engine,it widely used for pump station for flood control,irrigation and drainage.
2.Main Features of Horizontal Axial/Mixed Flow Water Pump for Irrigation
• Simple structure, reliable, easy fitting, and high efficiency, small body, light weight
• Transmission: direct drive and variable speed drives
• Operation stably,high efficiency
•Convenient installation and maintenance
•Customized design is available, OEM and ODM are welcomed.
3.Horizontal Axial/Mixed Flow Water Pump for Irrigation Images
4.Horizontal Axial/Mixed Flow Water Pump for IrrigationSpecification
Material | Cast Iron |
Capacity | 45-20000m3/hr |
Discharge | 3.7-20m |
5.FAQ
①What is the applications?
The pumps are used in flood dewatering application, water supplying and dewatering in urban area, storm-water drainage, agriculture and industry water supplying, water transfering etc.
②How to guarantee the quality of the products?
We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.
- Q:Water pumps are always pumping water, what's the matter?
- First check whether the water pump suction gas 2 check the negative pressure of the pump suction is too low 3 check whether the water pump 4 no problem of opening the pump head to check whether the water pump impeller damage
- Q:About 2 months ago I started hearing a noise coming from my bathroom that sounded like loud humming every 3 or 4 seconds after I would turn on the water or flush the toilet. I noticed that when this noise happened the water pressure would increase and then it would go back to normal. Then the noise started to get louder. Last night while my husband was taking a shower the water lost pressure and then completely turned off. Now I have no water at all whatsoever except for maybe a few drops when I turn the faucet on. I have a private well and when I bought the house I was told that the well is underneath one of my bedrooms because the house was built on to and they built over the well. I know I can get to the pump from the crawl space. Has anyone had this problem or does anyone know what it might be or maybe even how much it could cost to fix?
- can you take pump apart an clean
- Q:Is pumping water, the new pump is also this problem, the pump is also working, that is, no water, at night I opened, in the installation of water, second days also make it to noon is not so good
- What floor do you live on? If your floor is relatively high, the noon is not good, because there are too many people in the water (and maybe someone else is using a pump), so the water level is too far away from your house to pump it up
- Q:I am looking for a small water pump that I can turn on and off using a computer, preferably via USB. If someone could please post a link or a method of me doing this myself, I will be very appreciative.
- I'd look for a USB IO module, add a relay, and switch a standard pump.
- Q:Yesterday morning I was looking under my hood and I noticed that I was leaking water. It looked like the leak was coming from the water pump.I had to get to work, which is close by so I topped off the radiator and went to work. When I got to work I looked under the car and saw no leaking. I figured the radiator had ran dry although the car hadn't overheated, After work I started to fill the radiator to get home. I saw that I had leaked a little fluid but not much. I topped it off and picked up my son then went home. No overheating. No leaking. Today I've ran several errands and I've had no problems. What do you think was going on with my water pump yesterday?
- Yes underneath the pump is a small hole that will show a leak when the pump is on it's way out. Get it changed NOW.
- Q:My water pump is starting to leak. The shops are quoting $250- $300 to replace but I can buy a water pump at the auto parts store and install myself for less than $100 but I don't know what all is involved with this repair or if I should try (my only experience with car repair up to now is recently replacing the alternator). If anyone has done this please let me know what you think. thanks
- 1. okorder /
- Q:I'm just wondering where I should buy my new water pump for my 2.2 cavalier? Auto zone, carquest, checker? Does it matter which one?Thanks
- They all buy their water pumps from the same manufacturer. Beware !!! Don't trust the location of the weep hole from the original pump to line up the replacement. Don't trust the directions on the new pump to find the top for alignment. Unless the new pump lines up perfectly, rotate it until the bolt holes line up PERFECTLY. If the bolts are hard going back in, the pump is misaligned.
- Q:1995 Ford Contour GL, 2.0L 4Cyl- three water pump failures. I bought the car in 2000 [49,000 miles] and in 2003 [116,000 miles] a leak from the weep hole area was repaired by replacing the pump. In October, 2005 [164,000] another leak from the same place was again repaired by replacing the pump. Just over two years later now, 196,000 miles, and today it's leaking from the same area. Any idea why this would happen? Each time I've replaced the pump, I've not been able to see any damage to it. People talk about impellers breaking, but they've always seemed intact. Maybe it isn't a pump failure so much as a leak for some other reason? Since purchase, the car has run what appears to be hot, in that the temperature gauge, when at operating temps, is only a tick or two from overheating, but since it's in the normal range, I've always assumed it's just a faulty thermostat. It's never overheated except for when the leak has sprung up.Any thoughts? :)
- You could have a pulley that is bent or out of balance. Maybe your cooling system needs to be flushed and its putting a little extra load on the pump. You can check the temperature with an infra red thermometer to tell what the actual temperature of your engine is, then you'll know if your gage is accurate.
- Q:Im replacing the water pump on my cougar but i ran into a snag. I got the pump unbolted but to take it off, i need to unbolt a bracket that goes behind the power steering pump pulley. I cant figure out how to get that pulley off to take off the bracket. Any help with this would be greatly appreciated. Thank you.
- it would have helped if you had given an engine size of the car the procedure is different for a v-8,and a v-6 engine,i cant answer this because i don't know an engine size,,good luck,i suggest you get a good repair manual its more informative ,and gives real good details also.
- Q:my heater in my 94 ford ranger went out about a month ago today i flushed the heater core and it worked for a while and started going out again after i was driving for 15 to 20 mins. the hose going into the heater core was warm but coming out wasnt. could it have gotten clogged again or could it be something else.
- your right on the problem so to really figure it out take the hose off or lose enough to make a mess and see it flowing. Take it off at the water pump thats where it comes out at. the water pump pumps water into the radiator or up, not the other way around.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Horizontal Axial/Mixed Flow Water Pump for Irrigation
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords