Factory price china yuchai diesel generator sets 60kw
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 300 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
pecifications
open type dioesel generator with yuchai enginee
1) Factory direct sale
(2) CE, ISO9001 quality
Power range | 18-650KW |
Engine | All series powered by Yuchai engine |
Alternator | All series owning alternator options of Stamford/Marathon/ENGGA |
Controller system | Hanging control box, automatic control module Smartgen HGM6310 |
Base frame | International channel steel welded base, inbuilt composite damping system; sandblast, acid-washing, antiseptic treatment |
Radiator | Standard genset-joining radiator of 40 °C ambient temperature |
Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.
YUCHAI Series | Power(KW) | Power(KVA) | Jichai Engine Model | Cylinder NO. | Fuel consumption g/kw.h | DimensionL*W*H | Weight KG |
FKS-Y18 | 18 | 22.5 | YC2108D | 2 | ≤225 | 1700*700*1000 | 650 |
FKS-Y24 | 24 | 30 | YC2115D | 2 | ≤220 | 1700*700*1000 | 650 |
FKS-Y30 | 30 | 37.5 | YC2115ZD | 4 | ≤205 | 1700*750*1000 | 900 |
FKS-Y40 | 40 | 50 | YC4D60-D21 | 4 | ≤205 | 1800*750*1200 | 920 |
FKS-Y50 | 50 | 62.5 | YC4D85Z-D20 | 4 | ≤200 | 1800*750*1200 | 950 |
THY-64 | 64 | 80 | YC6B100-D20 | 6 | ≤205 | 2250*800*1300 | 1200 |
FKS-Y75 | 75 | 93.75 | YC6B135Z-D20 | 6 | ≤202 | 2250*800*1300 | 1250 |
FKS-Y90 | 90 | 112.5 | YC6B135Z-D20 | 6 | ≤202 | 2250*800*1300 | 1300 |
FKS-Y100 | 100 | 125 | YC6B155L-D21 | 6 | ≤200 | 2300*800*1300 | 1500 |
FKS-Y120 | 120 | 150 | YC6B180L-D20 | 6 | ≤192 | 2300*830*1300 | 1600 |
FKS-Y140 | 140 | 175 | YC6A210L-D20 | 6 | ≤192 | 2300*830*1300 | 1700 |
FKS-Y150 | 150 | 187.5 | YC6A230L-D20 | 6 | ≤192 | 2400*970*1500 | 2100 |
FKS-Y160 | 160 | 200 | YC6G245L-D20 | 6 | ≤195 | 2500*970*1500 | 2300 |
FKS-Y180 | 180 | 225 | YC6L285L-D30 | 6 | ≤197 | 2600*970*1550 | 2500 |
FKS-Y200 | 200 | 250 | YC6M350L-D20 | 6 | ≤197 | 3100*1050*1750 | 2750 |
FKS-Y220 | 220 | 275 | YC6M350L-D20 | 6 | ≤197 | 3100*1100*1750 | 2800 |
FKS-Y280 | 280 | 350 | YC6MK410L-D20 | 6 | ≤195 | 3200*1150*1750 | 3000 |
FKS-Y300 | 300 | 375 | YC6MK470L-D20 | 6 | ≤195 | 3200*1200*1750 | 3100 |
FKS-Y320 | 320 | 400 | YC6K500L-D30 | 6 | ≤195 | 3250*1200*1750 | 3200 |
FKS-Y350 | 350 | 437.5 | YC6K550L-D30 | 6 | ≤195 | 3250*1250*1750 | 3250 |
FKS-Y350 | 350 | 437.5 | YC6T550L-D21 | 6 | ≤195 | 3300*1250*1850 | 3500 |
FKS-Y400 | 400 | 500 | YC6T600L-D22 | 6 | ≤195 | 3400*1500*1970 | 3900 |
FKS-Y440 | 440 | 550 | YC6T660L-D20 | 6 | ≤195 | 3500*1500*1970 | 4000 |
FKS-Y500 | 500 | 625 | YC6T755L-D20 | 6 | ≤195 | 4000*1500*2000 | 5000 |
FKS-Y650 | 650 | 812.5 | YC6C1020L-D20 | 6 | ≤195 | 4500*1800*2500 | 7500 |
- Q: Hello friends.I had to make a list of equipment for a civil construction company. Among the equipment were generator and diesel engine. For generator, i am very clear that it is used for alternate power generation in case of electricity un availability. What is the purpose of diesel engine? Where is is used? Guide me please.
- Just about every piece of equipment powered by an internal combustion engine found at a civil construction site is powered by a diesel engine. Things such as scrapers, loaders, track hoes, dozers, dump trucks, rollers, and even electric generators are powered with diesel engines.
- Q: I built my own, verry successfull HHO gas generator and I want to inject the gas being produced, strait into my car engine but the flame keeps going back into my hose, i have going strait into the air intake carb, and blowing up my generator! I built a little flashback arrestor with gas piping filled with aquarium airstones and that obviously didn't work. Where can i buy a professional industrial flashback arrestor so I don't have to make my own?
- Sorry you can't!
- Q: Have a diesel engine that puts out average 3000 RPM and max's out at 3600 RPM I want to belt drive to a generator head that only needs 1800 RPM to operate at 60 hertz what size pulley should I use. Also for further info the shaft on diesel engine is 1 inch and the generator shaft is 42 millimeters
- If the engine is likely to be running for a long time, fuel consumption is likely to be important. You want to find out at what RPM the engine produces maximum torque.(If it's a car engine that will likely be related to the cruising speed of the car in top gear) All IC engines are most fuel efficient at the rpm for peak torque. If the engine can make enough power for your requirements at the rpm for peak torque, that's the rpm you should aim to run the engine at. Will depend on the engine of course, but peak torque is usually around about 1/3 of the rev range, I estimate that to be aprox 1800rpm [ie (3600-800)*1/3 +800 ] If aiming for 1800rpm for the generator, with an engine speed of 1800rpm, you don't need to change the rpm at all. That means the pulley's can be the same size, unless the belts slip (flat/ribbed belts slip aprox 3%- probably not enough for you to worry about) So that's the ratio sorted out. Physical size of pulley. All belts have a minimum diameter pulley which they can go around, so long as the pulley is larger there's no problem. Minimum size pulley depends on the thickness, and construction of the belt- and that depends on the power you're transferring via the belt. If you give some indication of the power you're wanting to transfer I'm, sure you get some additional help you'll probably need a governor for the engine to generate at 60Hz give or take a bit. Many diesel engines just have a max/min governor relying on the user to governing the rpm under varying load . You'll need fairly good control for electrically generation, but it needs be nothing much than releasing the throttle a little if the generator is running fast, and if the generator is running slow pressing the throttle. Hope that helps
- Q: Why not samoto diesel generator power
- the contact between the exciter brush and commutator is bad or the brush holder pressure is not enough.
- Q: Are they cranked by a self starter? Is there such an immensely powerful self starter that runs off batteries and can start such a big engine?Or are they started by some gasoline powered motor?
- A diesel engine is started (like an automobile) by turning over the crankshaft until the cylinders fire or begin combustion. The starting can be done electrically or pneumatically. Pneumatic starting was used for some engines. Compressed air was pumped into the cylinders of the engine until it gained sufficient speed to allow ignition, then fuel was applied to fire the engine. The compressed air was supplied by a smallauxiliary engine or by high pressure air cylinders carried by the locomotive. Electric starting is now standard. It works the same way as for an automobile, with batteries providing the power to turn a starter motor which turns over the main engine. In older locomotives fitted with DC generators instead of AC alternators, the generator was used as a starter motor by applying battery power to it.
- Q: how does a generator work powerlessly. i mean like if there is a black out people cna generate energy from like a generator. well then how come a generator work without the help of anything? (NOT TALKInG About the hydropower generator, the one that spins.
- Generators *always* take some kind of mechanical energy to operate. In the case of a power blackout, backup generators use large diesel engines rated for hundreds of thousands of Horsepower, to run the electrical backup generators. Those diesel engines (obviously) run on diesel fuel so, there is your 'anything'. .
- Q: has anyone ever heard of a 50cc diesel engine? if so, where could i get one and how much is it?also, i just want the engine, i dont want the rest of the scooter, bike, etc.
- This Site Might Help You. RE: 50cc diesel engine?????? has anyone ever heard of a 50cc diesel engine? if so, where could i get one and how much is it? also, i just want the engine, i dont want the rest of the scooter, bike, etc.
- Q: I accidentally filled my generator with diesel instead of unleaded. It already had a half a tank of unleaded so it has about half a tank of diesel. To make the full tank. Can anybody help me out please.
- Probably will not run. Diesel fuel will not burn unless under high compression and heat. That is why diesel engines use glow plugs instead of spark plugs and run a much higher compression ratio. Drain the fuel tank and refill with proper fuel.
- Q: Design the logic circuit for starting an emergency diesel generator. For the generator to start, the generator must be disconnected from the bus, there must be sufficient start air pressure, and the fuel tank must indicate there is oil. When these conditions are met, then the diesel may be started. Presume there are senors to determine these values.
- This is just an and gate function. When the outputs of all the sensors are true and a start command is present, the output of the gate will go high to allow the engine to start.
- Q: There are several ways to start the diesel generator set?
- will be cut to the automatic control switch (AUTO), and with automatic switching power switch (ATS) control switch shall be placed in automatic position, when the electricity stopped,