• Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor System 1
  • Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor System 2
Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor

Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

30kw to 1600kw Deutz Diesel Engine Generator

1. Deutz diesel Engine, 110v/220v Leroy alternator , 60Hz,

2. 24V DC start motor and storage battery

3. soundproof canopy , low noise

 

Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor

 

Specifications:

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displace

-ment

Bore X Stroke

Dimension         (L×B×H)mm

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRD16A

12

15

14

16

F2L912

≤238

2

1.88

100*120

1200*710*1030

GNRD28A

20

25

22

28

F3L912

≤232

3

2.82

100*120

1380*710*1030

GNRD41A

30

38

33

41

F4L912

≤228

4

3.77

100*120

1560*710*1030

GNRD55A

40

50

44

55

F6L912

≤228

6

5.65

100*120

1730*760*1050

GNRD68A

50

62

55

68

F6L913

≤228

6

6.12

100*120

1730*760*1050

GNRD75A

54

68

60

75

F6L912T

≤228

6

6.12

100*120

1760*760*1150

GNRD96A

70

88

77

96

BF6L91C3

≤228

6

6.12

102*125

2200*840*1370

GNRD28

20

25

22

28

D226B-3D

≤215

3

3

105*120

1600*780*1150

GNRD55

40

50

44

55

TD226B-3D

≤215

3

3

105*120

1880*700*1300

GNRD70

50

63

55

70

TD226B-4D

≤215

4

4

105*120

1990*750*1300

GNRD110

80

100

88

110

TD226B-6D

≤215

6

6

105*120

2190*780*1350

GNRD150

100

125

110

150

TBD226B-6D

≤215

6

6

105*120

2330*780*1450

GNRD206

150

188

165

206

BF6M1013FCG2

≤202

6

7.15

108*130

2520*960*1670

GNRD250

180

225

200

250

BF6M1013FCG4

≤202

6

7.5

108*130

2600*960*1690

GNRD300

220

275

240

300

TBD234V8-1A

≤195

8

14.4

128*140

2900*1240*1710

GNRD388

280

350

310

388

TBD234V8-1B

≤195

8

14.4

128*140

2930*1240*1710

GNRD413

300

375

330

413

BF6M1015CP-LAG

≤196

6

11.9

132*145

2620*1160*1810

GNRD500

360

450

400

500

TBD234V12-1A

≤196

12

21.6

128*140

3610*1240*1850

GNRD563

400

500

450

563

BF8M1015CP-LAG2

≤196

8

15.8

132*145

3380*1340*1890

GNRD625

450

563

500

625

TBD604BL6-2A

≤196

6

26.6

170*195

3950*1550*2069

GNRD750

540

675

600

750

TBD604BL6-2B

≤197

6

26.6

170*195

3970*1550*2065

GNRD875

630

788

700

875

TD620L6-2B

≤196

6

26.6

170*195

4480*1716*2210

GNRD1100

800

1000

880

1100

TBD620V8-2A

≤187

8

35.4

170*195

4400*2060*2350

GNRD1400

1000

1250

1120

1400

TBD620V12-2A

≤187

12

53.2

170*195

4930*2210*2500

GNRD1875

1350

1688

1500

1875

TBD620V12-2C

≤187

12

53.2

170*195

5160*2210*2500

GNRD2250

1600

2000

1800

2250

TBD620V16-2A

≤188

16

70.8

170*195

5500*2220*2600

GNRD2750

2000

2250

2200

2750

TBD622V20-2A

≤187

20

99.8

170*215

6600*2300*2800

 

Generator Deutz Features:

 

1. Genuine Detuz diesel engine

2. Radiator 40°C max,fans are driven by belt, with safety guard

3. Original Leroy Somer, Stamford, Marathon, or ENGGA alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9. Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Ripple flex exhaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards.

15. All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

General Technical Data

1. Frequency: 50 & 60Hz

2. Phase: 3 Phase 4 Wire & 1 Phase 2 Wire

3. Voltage: 120/207V,127/220V,220/380V, 230/400V, 240/415V, etc

4. Small volume, light weight, low noise, low fuel consumption, water cooling with water tank

5. Monitoring meters and control switches

6. Protection provided for short, over-current, over-speed, high water temperature and low oil pressure

Control Panel:

 

1. Automatic control panel (AMF), LCD display

2. Four protection systems

3. Emergency stop 

 

Optional:

 

1. Trailer type

2. Soundproof / open type

3. ATS(automatic transfer switch

 

Q: What's wrong with the rotary roller
It's possible that the roller card is dead You turn the drum manually and look at the ready
Q: What is the difference between explosion-proof motor and ordinary motor
The cooling fan at the tail end of the motor is used to keep the blades of the wind from the wind shield, and the outside of the wind blade is larger than the guide, and the blades are made of plastic. Why the appearance of explosion proof machine is so unflattering: because the front and rear cover is fixed by the hollow bolt and the socket is deep, it makes the ends appear not round and round. The junction box with a tube is a weird and complex structure, unlike a normal motor connection box. See the roundness and concise appearance that is used to general electric motor, look again the explosion-proof electric machine that has the Angle of a kind of strange Angle also can feel not good-looking! Hahaha, deep-sea diving cap, space cap, gas mask, dust respirator... People put it on his head and mouth, isn't it also worse than pig's mouth, is the functional structure, they have decided they ugly external shape, is helpless!
Q: What is the difference between a step motor and an ordinary motor
A dc motor usually requires only two lines, and the step motor requires 4-5 jumper lines The speed of dc motor is higher, and the speed of stepping motor is slower The Angle of rotation of the dc motor is difficult to calculate accu
Q: What is the difference between a frequency converter and a regular motor
Frequency conversion motor has great capacity of overload high mechanical strength, wide range of speed and running stability, the characteristics of general motor rated voltage is 380 v, rated frequency 50 hz, can within the scope of 3 hz ~ 100 hz continuous speed! The other converter motor has a special cooling fan!
Q: How does the motor stop
The motor and the emergency stop button are added in the control circuit of the motor. Methods: Connect the frequent closed contact of the emergency stop button to the start loop of the contactor. It's usually in front of the stop button. This way the control circuit stops working when pressing the emergency stop button.
Q: The difference between high voltage motor and general motors
A high voltage motor is defined by a voltage difference. For example, the high voltage motor is considered to be 1000V, 380V, 660V for low voltage motor. A general motor is a relative special motor. Such as drag pump, fan, compressor, crusher and so on. A high voltage motor is a motor that is rated at 1000V. The usual use is 6000V and 10000V voltage, which also has a voltage rating of 3300V and 6600V due to the different power grids in foreign countries. High voltage motor is due to the motor power is proportional to the product of the voltage and current, so the low voltage electrical power increases to a certain degree (such as 300 kw / 300 v) current limited to allow bear ability of the wire is hard to do big, or too expensive. High power output is required by increasing voltage. High voltage motor has the advantage of power and high impact ability. The drawback is that inertia is hard, starting and braking are difficult.
Q: Why is electric motors not rotating? Everything else is good.
Electric common failures and troubleshooting methods instrument display is normal, motor does not turn the cause of the problem: (1) brake the damage judgment (2) speed control to turn the damage judgment damage judgment, (4) (3) motor controller damaged troubleshooting: (1) remove the brake handle socket (normally open type brake handle). If the motor operates, the brake should be replaced. Turn the source 5V voltage to normal, check the signal voltage, turn the transfer, the signal voltage should be in 0.8 ~ 4.2 V from low to high. If the voltage is not changed and is less than 1V, then the fault or turn will be short-circuited. If the voltage is greater than 1V and the change is normal, the signal (yellow, green and blue) is detected. If the voltage of the three-phase hall signal line is 5V and is in good contact, the motor hall is damaged and the motor or motor hall elements should be replaced.
Q: What is the difference between a servo motor and a direct drive motor?
Servo motor is only converts electrical energy into mechanical energy, but it's lower also needs to connect all kinds of transmission device (such as belts, screw, wheel, etc.) to achieve your requirement; And straight don't need other gear drive motor, a direct connection device, such as the drum of the washing machine motor connected directly, and reduced the mechanical transmission part of the connecting parts
Q: The motor does not turn except sound
Is the connection ok? The sound of the urn is the coils of the coils. What's the electric motor.:If it's a single phase of the motor that might be a fault of the current or the initiating device, the third phase is the power supply,.
Q: Does the frequency conversion machine speak louder than the ordinary motor?
No, only when the frequency is low. It's basically the same as a normal machine in 10HZ.I hope my answer will help you

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords