Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
30kw to 1600kw Deutz Diesel Engine Generator
1. Deutz diesel Engine, 110v/220v Leroy alternator , 60Hz,
2. 24V DC start motor and storage battery
3. soundproof canopy , low noise
Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displace -ment | Bore X Stroke | Dimension (L×B×H)mm | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | ||||
GNRD16A | 12 | 15 | 14 | 16 | F2L912 | ≤238 | 2 | 1.88 | 100*120 | 1200*710*1030 |
GNRD28A | 20 | 25 | 22 | 28 | F3L912 | ≤232 | 3 | 2.82 | 100*120 | 1380*710*1030 |
GNRD41A | 30 | 38 | 33 | 41 | F4L912 | ≤228 | 4 | 3.77 | 100*120 | 1560*710*1030 |
GNRD55A | 40 | 50 | 44 | 55 | F6L912 | ≤228 | 6 | 5.65 | 100*120 | 1730*760*1050 |
GNRD68A | 50 | 62 | 55 | 68 | F6L913 | ≤228 | 6 | 6.12 | 100*120 | 1730*760*1050 |
GNRD75A | 54 | 68 | 60 | 75 | F6L912T | ≤228 | 6 | 6.12 | 100*120 | 1760*760*1150 |
GNRD96A | 70 | 88 | 77 | 96 | BF6L91C3 | ≤228 | 6 | 6.12 | 102*125 | 2200*840*1370 |
GNRD28 | 20 | 25 | 22 | 28 | D226B-3D | ≤215 | 3 | 3 | 105*120 | 1600*780*1150 |
GNRD55 | 40 | 50 | 44 | 55 | TD226B-3D | ≤215 | 3 | 3 | 105*120 | 1880*700*1300 |
GNRD70 | 50 | 63 | 55 | 70 | TD226B-4D | ≤215 | 4 | 4 | 105*120 | 1990*750*1300 |
GNRD110 | 80 | 100 | 88 | 110 | TD226B-6D | ≤215 | 6 | 6 | 105*120 | 2190*780*1350 |
GNRD150 | 100 | 125 | 110 | 150 | TBD226B-6D | ≤215 | 6 | 6 | 105*120 | 2330*780*1450 |
GNRD206 | 150 | 188 | 165 | 206 | BF6M1013FCG2 | ≤202 | 6 | 7.15 | 108*130 | 2520*960*1670 |
GNRD250 | 180 | 225 | 200 | 250 | BF6M1013FCG4 | ≤202 | 6 | 7.5 | 108*130 | 2600*960*1690 |
GNRD300 | 220 | 275 | 240 | 300 | TBD234V8-1A | ≤195 | 8 | 14.4 | 128*140 | 2900*1240*1710 |
GNRD388 | 280 | 350 | 310 | 388 | TBD234V8-1B | ≤195 | 8 | 14.4 | 128*140 | 2930*1240*1710 |
GNRD413 | 300 | 375 | 330 | 413 | BF6M1015CP-LAG | ≤196 | 6 | 11.9 | 132*145 | 2620*1160*1810 |
GNRD500 | 360 | 450 | 400 | 500 | TBD234V12-1A | ≤196 | 12 | 21.6 | 128*140 | 3610*1240*1850 |
GNRD563 | 400 | 500 | 450 | 563 | BF8M1015CP-LAG2 | ≤196 | 8 | 15.8 | 132*145 | 3380*1340*1890 |
GNRD625 | 450 | 563 | 500 | 625 | TBD604BL6-2A | ≤196 | 6 | 26.6 | 170*195 | 3950*1550*2069 |
GNRD750 | 540 | 675 | 600 | 750 | TBD604BL6-2B | ≤197 | 6 | 26.6 | 170*195 | 3970*1550*2065 |
GNRD875 | 630 | 788 | 700 | 875 | TD620L6-2B | ≤196 | 6 | 26.6 | 170*195 | 4480*1716*2210 |
GNRD1100 | 800 | 1000 | 880 | 1100 | TBD620V8-2A | ≤187 | 8 | 35.4 | 170*195 | 4400*2060*2350 |
GNRD1400 | 1000 | 1250 | 1120 | 1400 | TBD620V12-2A | ≤187 | 12 | 53.2 | 170*195 | 4930*2210*2500 |
GNRD1875 | 1350 | 1688 | 1500 | 1875 | TBD620V12-2C | ≤187 | 12 | 53.2 | 170*195 | 5160*2210*2500 |
GNRD2250 | 1600 | 2000 | 1800 | 2250 | TBD620V16-2A | ≤188 | 16 | 70.8 | 170*195 | 5500*2220*2600 |
GNRD2750 | 2000 | 2250 | 2200 | 2750 | TBD622V20-2A | ≤187 | 20 | 99.8 | 170*215 | 6600*2300*2800 |
Generator Deutz Features:
1. Genuine Detuz diesel engine
2. Radiator 40°C max,fans are driven by belt, with safety guard
3. Original Leroy Somer, Stamford, Marathon, or ENGGA alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9. Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Ripple flex exhaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards.
15. All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
General Technical Data
1. Frequency: 50 & 60Hz
2. Phase: 3 Phase 4 Wire & 1 Phase 2 Wire
3. Voltage: 120/207V,127/220V,220/380V, 230/400V, 240/415V, etc
4. Small volume, light weight, low noise, low fuel consumption, water cooling with water tank
5. Monitoring meters and control switches
6. Protection provided for short, over-current, over-speed, high water temperature and low oil pressure
Control Panel:
1. Automatic control panel (AMF), LCD display
2. Four protection systems
3. Emergency stop
Optional:
1. Trailer type
2. Soundproof / open type
3. ATS(automatic transfer switch
- Q: What's wrong with the rotary roller
- It's possible that the roller card is dead You turn the drum manually and look at the ready
- Q: What is the difference between explosion-proof motor and ordinary motor
- The cooling fan at the tail end of the motor is used to keep the blades of the wind from the wind shield, and the outside of the wind blade is larger than the guide, and the blades are made of plastic. Why the appearance of explosion proof machine is so unflattering: because the front and rear cover is fixed by the hollow bolt and the socket is deep, it makes the ends appear not round and round. The junction box with a tube is a weird and complex structure, unlike a normal motor connection box. See the roundness and concise appearance that is used to general electric motor, look again the explosion-proof electric machine that has the Angle of a kind of strange Angle also can feel not good-looking! Hahaha, deep-sea diving cap, space cap, gas mask, dust respirator... People put it on his head and mouth, isn't it also worse than pig's mouth, is the functional structure, they have decided they ugly external shape, is helpless!
- Q: What is the difference between a step motor and an ordinary motor
- A dc motor usually requires only two lines, and the step motor requires 4-5 jumper lines The speed of dc motor is higher, and the speed of stepping motor is slower The Angle of rotation of the dc motor is difficult to calculate accu
- Q: What is the difference between a frequency converter and a regular motor
- Frequency conversion motor has great capacity of overload high mechanical strength, wide range of speed and running stability, the characteristics of general motor rated voltage is 380 v, rated frequency 50 hz, can within the scope of 3 hz ~ 100 hz continuous speed! The other converter motor has a special cooling fan!
- Q: How does the motor stop
- The motor and the emergency stop button are added in the control circuit of the motor. Methods: Connect the frequent closed contact of the emergency stop button to the start loop of the contactor. It's usually in front of the stop button. This way the control circuit stops working when pressing the emergency stop button.
- Q: The difference between high voltage motor and general motors
- A high voltage motor is defined by a voltage difference. For example, the high voltage motor is considered to be 1000V, 380V, 660V for low voltage motor. A general motor is a relative special motor. Such as drag pump, fan, compressor, crusher and so on. A high voltage motor is a motor that is rated at 1000V. The usual use is 6000V and 10000V voltage, which also has a voltage rating of 3300V and 6600V due to the different power grids in foreign countries. High voltage motor is due to the motor power is proportional to the product of the voltage and current, so the low voltage electrical power increases to a certain degree (such as 300 kw / 300 v) current limited to allow bear ability of the wire is hard to do big, or too expensive. High power output is required by increasing voltage. High voltage motor has the advantage of power and high impact ability. The drawback is that inertia is hard, starting and braking are difficult.
- Q: Why is electric motors not rotating? Everything else is good.
- Electric common failures and troubleshooting methods instrument display is normal, motor does not turn the cause of the problem: (1) brake the damage judgment (2) speed control to turn the damage judgment damage judgment, (4) (3) motor controller damaged troubleshooting: (1) remove the brake handle socket (normally open type brake handle). If the motor operates, the brake should be replaced. Turn the source 5V voltage to normal, check the signal voltage, turn the transfer, the signal voltage should be in 0.8 ~ 4.2 V from low to high. If the voltage is not changed and is less than 1V, then the fault or turn will be short-circuited. If the voltage is greater than 1V and the change is normal, the signal (yellow, green and blue) is detected. If the voltage of the three-phase hall signal line is 5V and is in good contact, the motor hall is damaged and the motor or motor hall elements should be replaced.
- Q: What is the difference between a servo motor and a direct drive motor?
- Servo motor is only converts electrical energy into mechanical energy, but it's lower also needs to connect all kinds of transmission device (such as belts, screw, wheel, etc.) to achieve your requirement; And straight don't need other gear drive motor, a direct connection device, such as the drum of the washing machine motor connected directly, and reduced the mechanical transmission part of the connecting parts
- Q: The motor does not turn except sound
- Is the connection ok? The sound of the urn is the coils of the coils. What's the electric motor.:If it's a single phase of the motor that might be a fault of the current or the initiating device, the third phase is the power supply,.
- Q: Does the frequency conversion machine speak louder than the ordinary motor?
- No, only when the frequency is low. It's basically the same as a normal machine in 10HZ.I hope my answer will help you
Send your message to us
Deutz Genset Diesel Generator 1600kw With 24V DC Start Motor
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords