• Water Cooled Perkins Genset Diesel Generator 7kva To 1000kva For House System 1
  • Water Cooled Perkins Genset Diesel Generator 7kva To 1000kva For House System 2
Water Cooled Perkins Genset Diesel Generator 7kva To 1000kva For House

Water Cooled Perkins Genset Diesel Generator 7kva To 1000kva For House

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Water Cooled Perkins Genset Diesel Generator 7kva To 1000kva For House

 

 

Quick Detail:

1.UK Perkins Diesel Engine 

2.Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3.three phase four wire,single bearing generator

4.50Hz/60Hz,220v/380v,230v/400v,240v/415v

 

 

Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

1. Genuine UK industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

Optional:

1. Trailer type

2. Soundproof / water proof

3. ATS (automatic transfer switch)

4. Parallel system

5. Remote system

 

PMC System:

1. Standard 23 pitch windings avoid excessive neutral current

2. Permanent magnet generator system provides constant excitation under all condition

3. Optional accessories available for easy paralleling with mains or other generators

4. AVR auto voltage regulation, auto exciter, auto adjustment

Q: How does the motor stop
The motor and the emergency stop button are added in the control circuit of the motor. Methods: Connect the frequent closed contact of the emergency stop button to the start loop of the contactor. It's usually in front of the stop button. This way the control circuit stops working when pressing the emergency stop button.
Q: Is the servo motor to be used as a common motor?
Due to the overload ability of servo motor, the rated torque of servo motor can be determined by reference to 1/3 of the output torque of the motor.
Q: What is the difference between a three-phase asynchronous motor and a regular motor?
Three-phase asynchronous motor cooling fan is fixed on the motor shaft, the same as the rotation speed of the motor, low frequency is run, the fan is running at low speed, the cooling capacity drops greatly, the heat generated by the motor can't send out, serious when burning motor. The structure and pressure capacity of the inverter motor are specially designed to accommodate high speed and high harmonics. Motor has the branch of general motor and frequency conversion motor, called main appearance is different from ordinary motor frequency conversion motor frequency conversion motor is packed with centrifugal fan forced cooling, this ensures the motor at low frequency and high frequency heat dissipation is good, and frequency conversion motor internal structure can adapt to the high frequency operation of specific working frequency range see nameplate. General motors generally allow only running under 50hz.
Q: The difference between the frequency converter and the ordinary motor
The structure design Structure design, main is also considering the non-sinusoidal power characteristics of variable frequency motor insulation structure, the influence of vibration and noise cooling mode, generally pay attention to the following questions: 1) insulation level, which is generally F or higher, strengthens the insulation strength of the ground and turns, especially considering the ability of insulation to withstand shock voltage. 2) to the problem of vibration and noise of the motor, the motor should be fully considered component and overall rigidity, trying to improve its natural frequency, in order to avoid and every force wave resonance phenomenon. 3) cooling mode: the general adoption of forced ventilation cooling, the main motor cooling fan is driven by an independent motor. To prevent shaft current measures, the bearing insulation measures should be applied to the capacity exceeding 160KW motors. Mainly produces magnetic circuit asymmetry, also can produce shaft current, while the rest of the high frequency component generated by the current role in combination, shaft current will increase greatly, which can lead to bearing damage, so often insulation measures. For constant power frequency converter motor, the special lubricating grease should be used to compensate the temperature of the bearings when the speed is over 3000 / min.
Q: Does the motor swing around?
The rotation must be oscillating, and the motor will also produce the left and right swings of the left and right sides
Q: Can you use a transducer to control the general motors? Recently, the factory has to renovate two 150 kw electric motors, which were previously controlled by the star delta, and now change the frequency converter, the electric motor is near the stove, the ambient temperature is higher. Please give me your opinion, thank you
If you don't reload frequently, not reload, you don't have to work long hours at low frequencies, and you have a fan that's basically ok.
Q: Why does the direct start-up of high power motors affect the voltage of the grid
Because of the asynchronous motor starting, the rotor has not turned up, the stator rotating magnetic field cutting speed relative to the rotor conductors, in rotor induction electric potential is very big, so the current is very big, if starting directly from grid, starting current can reach 4 to 7 times the rated current, and is the most current inductive current, this would have had a big impact on the grid: 1) the large starting current will be produced on the transmission line, the larger voltage drop; 2) because so much of the starting current, most of it is a perceptual current, will cause a demagnetization effect on the grid, and will also cause the grid voltage to fluctuate.
Q: The amount of the machine is doubled, all the other motors are unchanged, the rated torque and the speed change.
The core thickness of the motor is doubled, and for the ideal click, you can think: Both the load and the rated speed are the same as the original 1/2. Both the rated torque and the torque torque are twice as large.
Q: The difference between servo motor and general motor?
The insulation level, which is usually F or higher, strengthens the insulation strength of the ground and turns, especially considering the ability of insulation to withstand shock voltage. 2) to the problem of vibration and noise of the motor, the motor should be fully considered component and overall rigidity, trying to improve its natural frequency, in order to avoid and every force wave resonance phenomenon. 3) cooling mode: the general adoption of forced ventilation cooling, the main motor cooling fan is driven by an independent motor. To prevent shaft current measures, the bearing insulation measures should be applied to the capacity exceeding 160KW motors. Mainly produces magnetic circuit asymmetry, also can produce shaft current, while the rest of the high frequency component generated by the current role in combination, shaft current will increase greatly, which can lead to bearing damage, so often insulation measures. For constant power frequency converter motor, the special lubricating grease should be used to compensate the temperature of the bearings when the speed is over 3000 / min.
Q: What is the difference between an energy-saving motor and a general motor
Features of high efficiency energy-saving motor: 1, save energy and reduce long-term operation cost, very suitable for textile, fan, water pump, compressor, power saving a year recoverable motor acquisition cost. The machine can be switched on and off, and the asynchronous machine can be replaced completely. 3, rare earth permanent magnet high efficiency and energy saving motor itself than ordinary more than 15 ℅ save power. The power factor of the motor is close to 1, improving the quality factor of the power grid without the power factor compensator. Small electric current, saving power distribution capacity and extending the overall operating life of the system.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords