50kva to 800kva Trailer Genset
1. 250kva Cummins ,Perkins and Deuz diesel engine
2. Volt 220V/380V, 230V/400V, 240V/415V
3. Double Axle ,4 Wheels
50kva - 800kva Trailer Genset Diesel Generator Double Axle 4 Wheels
Specifications:
Trailer Generator with Turn-table
1. Standard: GB/T2819-1995
2. Single Axle and Double Axle Wheels is available.
3. Heavy Duty Reinforced M.S Chassis, with 8 hours base fuel tank
4.High Strength, impact-resistance, anti-deformation
5. Exclusive water resistance structure, inspection windows, maintenance door in each side
6. Flexible connection lug design insure excellent buffer performance
7. Max. workable Speed 40 km/hr
Engine Features:
1. World most famous brand diesel engine: Cummins.Perkins . Doosan. etc
2. Mufti-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
Soundproof/Slient Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and safety
6. 1m<80dB/7m<70dB/68dB
Control Panel Features:
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
Warranty policy
Guarantee for one year or 1000 hours whichever reach first from ex-factory date. During the guarantee period, Genor will provide the free easy-damageable spare parts of diesel engine caused by our quality of production or raw material. After expiration, Genor provides cost spare parts maintenance of gensets.
- Q:What are the characteristics of plateau motors? Why can't the general motors be used for plateau areas
- Compared with ordinary motor, plateau motor is adjusted for insulation strength, electrical clearance, temperature limit and anti-halo measures. 1, the increase in elevation causes the insulation strength to decrease: the insulation intensity should be reduced by 8 to 15% for every 1000 metres. 2, the breakdown voltage of the electrical clearance is decreased, so the need to increase the electrical clearance in accordance with the elevations. For high voltage motor, the initial voltage of the corona is reduced, and the anti-stun measures should be strengthened. The cooling effect of air dielectric decreases, the heat dissipation capacity decreases, the temperature rise increases, each increase of 1000M, the temperature rise should increase by 3-10%, so the temperature rise limit should be corrected. The high altitude is unfavorable to the dc motor. Pay attention to the choice of carbon brush material.
- Q:There is a difference between the electric motor and the other motors
- The electric motor is also a three-phase asynchronous motor that drives direct current through the inverter to the three-phase square wave current to drive the motor spinning
- Q:Why does the direct start-up of high power motors affect the voltage of the grid
- Cage motor direct starting current is rated current of 6 ~ 7 times, large motor starting current is up to thousands of A, caused the high current on the pressure drop caused by power grid voltage drop.
- Q:Why is electric motors not rotating? Everything else is good.
- The voltage should be greater than 36V (the battery is sufficient), and the input line should be checked if there is no voltage. Check the controller to turn the power supply voltage (switching of the red, black), normal voltage in 5 ~ 6 v, if there is no 5 v voltage, unplug the socket, restore 5 v voltage, hall element may be for motor short circuit, if still no 5 v voltage, is used as the controller, the controller should be replaced. First of all, check the speed of adjustment and the opening of the motor hall to have a short circuit.
- Q:What is the difference between a step motor and an ordinary motor
- Stepper motor and the general difference is mainly lies in the form of the pulse drive (send a pulse control system, can give in a rotary Angle of motor), because of the characteristics of step motor can be combined with modern digital control technology (particularly suitable for mechanical and electrical integration products). However, it is inferior to the traditional closed-loop dc servo motor in the accuracy, speed range and low speed performance of the step motor. It is possible to use stepping motor in an environment where precision is not particularly high, and the step motor can be characterized by simple structure, high reliability and low cost. When used properly, it can even be compared to the performance of dc servo motors.
- Q:How do you differentiate the converter motor from the general motors?
- Variable frequency motor and the common one of the biggest difference is the fan cooling way, general motors was the cold, the fan on the motor shaft, changes with the rotational speed of the motor, so the ordinary motor at low frequency heat dissipation is not ideal. Frequency conversion motor cooling fan is behind the motor equipped with a cooling fan, need an external power, the fan will not be affected by the speed of the motor, is a strong refrigeration.
- Q:In what situations does the step motor lose?
- Stepper motor lose step and positioning, usually caused by the following reasons: 1, change direction when pulse, were characterized by any one direction, but a change of direction is the cumulative deviation, the more and more wide; 2, the initial velocity is too high, the acceleration is too big, cause sometimes to lose step; Too much or too little to be compensated for in the synchronous belt. Not enough motor power; 5, the controller is disturbed to cause the wrong action. The drive is caused by interference; Software bugs. Want to be specific analysis?
- Q:What is a hydraulic motor
- The high speed motor gear motor has the advantages of small size, light weight, simple structure, good technology, not sensitive to the pollution of the oil, the shock resistance and small inertia. The disadvantages include higher torque ripple, low efficiency, low starting torque (60% to rated torque) and low speed stability.
- Q:The abnormal sound of a three-phase machine
- First rule out the factors of lack of phase, because motor open phase, a few seconds can be burned motors. In this case, there are several possible: 1, the motor winding fault, lead to motor disorder, internal magnetic field should be quickly find out the reason, simple method is to check the motor phase current balance
- Q:The difference between pump motor and general motor?
- The difference between pump motor and ordinary motor is mainly the shell of the motor and its protection, the oil pump motor casing is sealed explosion-proof type.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
50kva - 800kva Trailer Genset Diesel Generator Double Axle 4 Wheels
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords