• 50kva - 1500kva Cummins Diesel Generator 20kw - 1600kw System 1
  • 50kva - 1500kva Cummins Diesel Generator 20kw - 1600kw System 2
50kva - 1500kva Cummins Diesel Generator 20kw - 1600kw

50kva - 1500kva Cummins Diesel Generator 20kw - 1600kw

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1500 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

50kva to 1500kva Cummins Diesel Generator

1. KTA19-G4   KTA38-G5  KTA38-GA Cummins engine 
2. AC alternator: 
Leroy Somer, Stamford, Marathon
3. 10-hour operation base tank

 

50kva - 1500kva Cummins Diesel Generator 20kw - 1600kw

 

Specifications:

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G1

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190

 

Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Super Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

Q: The problem of single chip machine controlling motor
Model all MCU can be, I feel the difficulty in stepper motor control, buy the finished product of stepper motor drives, you only need to send pulse with single-chip computer. I don't feel the need for this application, you can control it on your own IO. Because I don't have the experience of this, it's a discussion.
Q: How does the motor stop
Emergency stop switch: just for a switch, usually use red or yellow mushroom head button, plays the role of the emergency stop in control circuit, so that the emergency stop switch The first method, which is also the usual addition, sets a closed contact switch in tandem with the motor's contactor coil circuit. It is possible to power the contactor in the job, so that the electric motor that runs through the contactor is lost to the purpose of the emergency stop. Method 2: there are also some three phase power switch (motor power) with control contact. Use the emergency stop switch to control the three-phase power switch. The electric motors that are run by the contactor are lost to the purpose of an emergency stop. The first is gm, the second is more expensive. Supplement: Is three motor, there is a knife, and later began to work, I have a red emergency stop switch, I'd like to know more things, so pick up to press the machine stop? You can buy another contactor. Follow the first method.
Q: What is the difference between a single phase motor and a two-phase machine?
Motor has single-phase ac motor and three-phase motor. I haven't heard of a two-phase machine. Are you asking for a positive reverse motor? Three phases are phase modulation. Any two phases are exchanged. C, R, S.
Q: In the case of ac motor, the voltage will be higher or lower in constant voltage, which will affect the motor.
The frequency can affect the speed of the motor, the frequency is high, the motor speed is fast, the frequency is low, the motor speed is slow. Of course, the high frequency of the motor will be higher, but the fan will also be faster, so there is basically no effect.
Q: A 2.2 KW motor will require a lot of electricity a day
The actual power of the three-phase ac motor is 1.732 UIcos phi Three-phase ac motor is used for the power of Q = Pt Among them: Cosine of phi: the power factor for the motor is 0.85. P: the actual power of the motor, unit: kW. U: the actual voltage of the motor, unit: kV. I: the actual current of the motor, the average of the three phase current, unit: A. T: the actual running time of the motor, unit: hour. Q: the actual power of the motor, the unit kWH.
Q: The problem of speed regulating motor and general motors
With frequency converter, of course, will not shorten the life of the motor, ordinary motor frequency converter will be used to take, no problem at all, music fountain is with motor with frequency converter
Q: Can ordinary motors use a frequency converter?
Motor insulation strength problem Small and medium frequency converters, many of which are controlled by PWM. He is about several thousand to more than 10 KHZ carrier frequency, which makes the motor stator winding to withstand high voltage build-up rate, equivalent to impose great impulse voltage gradient on motor, the motor of the turn-to-turn insulation withstand ordeal. In addition, the rectangular produced by PWM inverter chopper superposition of impulse voltage on the motor running voltage, would pose a threat to ground insulation of motor, the ground under the repeated impact of high voltage insulation can accelerate ageing. 3, harmonic electromagnetic noise and vibration Ordinary asynchronous motors, when powered by a frequency converter, can complicate the vibration and noise caused by factors such as electromagnetism, mechanical and ventilation. The internal harmonic interference of the different time harmonic and the electromagnetism of electromagnetism in the frequency conversion power supply, form various electromagnetic excitation forces. When the frequency of the electromagnetic wave is consistent or close to the natural vibration frequency of the motor body, the resonant phenomenon will be generated to increase the noise. Because the frequency of the motor is wide, the speed varies widely, and the frequency of all kinds of electromagnetic waves is difficult to avoid the natural vibration frequency of each component of the motor.
Q: Why does the direct start-up of high power motors affect the voltage of the grid
Because the instantaneous starting current of the three-phase machine is five to seven times the rated electric current, the voltage of the line is reduced, and the voltage of the power grid and the zhou wave are low. Therefore, the high power motor should be initiated by star/Angle to reduce the starting current and avoid the large fluctuation in the voltage of the grid. The star triangulation is initiated by changing the connection of the motor winding, and the pressure is actuated. When activated, the main contactor will give the power to the three ends of the motor winding, which will close the three ends of the motor winding. Winding becomes a star connection, after the completion of the start, time relay action, star contactor disconnect, contactor operation will be three of the power supply to the motor winding end. The winding becomes a delta connection. The motor is fully pressed. During startup, the asterisk contactor and the operating contactor must be interlinked. Image: KT - time relay, KM1 - star contactor, KM2 - the main contactor, KM3 - the operating contactor.
Q: What is the electric motor in the car seat?
The two lines are the wires of the motor rotor, and the three lines are the line of the motor controller (the seat control switch is connected to the controller of the seat motor to be controlled before and after the motor is controlled).
Q: The difference between a two-speed motor and a regular motor
1, there are two different embedded in the stator slot logarithm of winding, by changing the external control line to change of motor stator winding connection to realize the logarithm change poles; Two separate winding logs embedded in the stator slot;

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords