50kva to 1500kva Cummins Diesel Generator

1. KTA19-G4   KTA38-G5  KTA38-GA Cummins engine 
2. AC alternator: 
Leroy Somer, Stamford, Marathon
3. 10-hour operation base tank

 

50kva - 1500kva Cummins Diesel Generator 20kw - 1600kw

 

Specifications:

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRC30

20

25

24

30

4B3.9-G

≤229

4

3.9

102*120

GNRC35

24

30

28

35

4BT3.9-G

≤214

4

3.9

102*120

GNRC56

40

50

45

56

4BTA3.9-G

≤215

4

3.92

102*120

GNRC63

45

56

50

63

4BTA3.9-G

≤215

4

3.92

102*120

 GNRC70

50

63

56

70

6BT5.9G1

≤215

6

5.88

102*120

GNRC106

78

98

85

106

6BT5.9G

≤215

6

5.88

102*120

GNRC125

90

113

100

125

6BT5.9G2

≤215

6

5.88

102*120

GNRC150

104

130

120

150

6BT5.9G2

≤215

6

5.88

102*120

GNRC165

120

150

132

165

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC200

140

175

160

200

6CTA8.3-G2

≤210

6

8.3

114*135

GNRC225

160

200

180

225

6CTAA8.3-G2

≤210

6

8.3

114*135

GNRC275

200

250

220

275

6LTAA8.9-G2

≤210

6

8.3

114*135

GNRC313

220

275

250

313

NTA855-G1A

≤206

6

14

140*152

GNRC350

250

313

275

350

NTA855-G2

≤207

6

14

140*152

GNRC400

280

350

310

400

NTA855-G4

≤208

6

14

140*152

GNRC413

300

375

330

413

NTAA855-G7

≤206

6

14

140*152

GNRC450

320

400

360

450

NTAA855-G7A

≤206

6

14

140*152

GNRC500

360

450

400

500

KTA19-G3

≤203

6

18.9

159*159 

GNRC550

400

500

440

550

KTA19-G4

≤203

6

18.9

159*159 

GNRC605

440

550

484

605

KTAA19-G6

≤204

6

18.9

159*159 

GNRC625

450

563

500

625

KTAA19-G7

≤204

6

18.9

159*159 

GNRC700

500

625

560

700

KTA38-G

≤206

12

37.8

159*159 

GNRC712

520

650

570

712

QSK19-G3

≤206

6

19

159*159 

GNRC800

580

720

640

800

KTA38-GA

≤209

12

37.8

159*159 

GNRC825

600

750

660

825

KTA38-G2

≤210

12

37.8

159*159 

GNRC888

640

800

710

888

KTA38-G2B

≤210

12

37.8

159*159 

GNRC975

720

900

780

975

KTA38-G2A

≤210

12

37.8

159*159 

GNRC1075

800

1000

860

1075

KTA38-G5

≤202

12

37.8

159*159 

GNRC1375

1000

1250

1100

1375

KTA50-G3

≤215

16

50.3

159*159

GNRC1375

1100

1375

1310

1650

KTA50-G8

 ≤215

16

50.3

159*159

GNRC1650

1200

1500

1340

1675

KTA50-GS8

 ≤215

16

50.3

159*159

GNRC1675

1350

1688

1500

1875

QSK60-G3

 ≤215

16

60

159*159

GNRC1875

1500

1875

1650

2063

QSK60-G3

 ≤215

16

60

159*190

GNRC2063

1600

2000

1800

2250

QSK60-G4

 ≤215

16

60

159*190

 

Genset Features:

1. Genuine Commins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14.   Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

Engine Features:

1. Genuine Cummins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

Alternator Features:

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

Main Functions:

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

Super Soundproof/Silent Box:

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

Q: How do you differentiate the converter motor from the general motors?
Variable frequency motor and the common one of the biggest difference is the fan cooling way, general motors was the cold, the fan on the motor shaft, changes with the rotational speed of the motor, so the ordinary motor at low frequency heat dissipation is not ideal. Frequency conversion motor cooling fan is behind the motor equipped with a cooling fan, need an external power, the fan will not be affected by the speed of the motor, is a strong refrigeration.
Q: The difference between pump motor and general motor?
Oil pump motor, also known as explosion-proof motor, is mainly used in coal mines, oil and gas, petrochemical and chemical industry. In addition, in textile, metallurgy, city gas, transportation, grain oil processing, paper, medicine and other departments are also widely used. The oil pump motor is used as the main power equipment, which is commonly used to drive pump, fan, compressor and transmission machine. And ordinary motors are not explosion-proof and can not be used in coal mines, oil and gas, petrochemical and chemical industries.
Q: What is the difference between a general motor and a high-speed motor?
The rotational inertia of high speed motor is generally small, so the long type of motor is more.
Q: In what situations does the step motor lose?
Stepper motor lose step and positioning, usually caused by the following reasons: 1, change direction when pulse, were characterized by any one direction, but a change of direction is the cumulative deviation, the more and more wide; 2, the initial velocity is too high, the acceleration is too big, cause sometimes to lose step; Too much or too little to be compensated for in the synchronous belt. Not enough motor power; 5, the controller is disturbed to cause the wrong action. The drive is caused by interference; Software bugs. Want to be specific analysis?
Q: Does the motor swing around?
The motor bearing is out of question, causing the left and right oscillation.I hope my answer will help you.
Q: The difference between PWM and general motors
Frequency conversion motor adopts "special inverter induction motor + frequency converter" way of ac speed regulation, make the mechanical automation degree and greatly improved the efficiency of production equipment miniaturization, increase comfort, is to replace the traditional mechanical control and dc speed control scheme.
Q: Can you use a transducer to control the general motors? Recently, the factory has to renovate two 150 kw electric motors, which were previously controlled by the star delta, and now change the frequency converter, the electric motor is near the stove, the ambient temperature is higher. Please give me your opinion, thank you
If you don't reload frequently, not reload, you don't have to work long hours at low frequencies, and you have a fan that's basically ok.
Q: What is the meaning of the motor from cold and cold?
Self-cooling: the surrounding environment, and the holes in the ends of the cover, reduce the temperature of the motor Forced cooling: other help For example: add a fan to the shaft The channel is designed to reduce the temperature through the flow of cold water The oil in the transformer is cold
Q: What is the difference between ordinary motor, step motor and servo?
Step motor, rotor is permanent magnet type corresponding magnetic pole! Controlled in stator pulsed magnetic field can achieve precision step in! Apply to instrument and automatic control and drag! Less accurate than servo motor!
Q: What is the electric motor in the car seat?
The simple point is the signal line, and the seat motor is usually the synchronous motor.The two power lines are the control motors, and those three are the controllers that control the rotation and inversion of the motors