1. Description of Horizontal Multistage Water Pumps
1>Horizontal multistage design with stainless steel stamping welding impeller and diffuser,three different type of choice.
2>Single phase motor up to 2.2kw,Class F and IP55 motor is standard.
3>Standard supply for liquid temperature up to 70 degree centigrade,high temperature pump are available on request.
2. Application for Horizontal Multistage Water Pumps
1>cooling water system
2>agriculture
3>domestic water supply
4>general industrial services
5>washing
6>enviroment protection
3. Performance range for Horizontal Multistage Water Pumps
capacity: Q up to 32m3/h
head H up to 110 degree centigrade
speed: n 2900rpm or 3500rpm
power: P up to 55kw *2
4. Standard material of Horizontal Multistage Water Pumps
All the parts contact with liquid made of 304 stainless steel on request.The pump head and suction & discharge can be made of cast iron on request too.
5. RFQ
1> What's the difference for CHL and CHLF(T) type?
CHL pumps have an inlet and outlet chamber which is made by stainless steel. CHLF(T) is just the section type.
2> Do you have any variable motor for these pumps?
Yes, we have. For the variable motor, the frequence can be changed as the customers' request. If the range is between 30~50Hz, the fan can be just connected with the shaft. And if the frequency is below 30Hz, then the fan has to have another separated power. The variable speed motor would be used for solar energy or some other similar situation with the unstable power.
3> How about the Delivery time?
Actually, this would be depending on the quantity. If it is just small order, 1 week would be fine. For bigger quantity, the delivery would be also less then 20 days. But for the varible speed ones, it will be taking some more time, normally it will be more than a month.
- Q: my basement flooded and the water came in contact with the wiring on my water pump.Now the pump tries to turn on but shuts off without pumping any water.How do i get my pump pumping water again?
- sounds like the bearings locked up...best to replace it
- Q: How many lift pumps should be used for 100 meters tall buildings?
- 35m lift around. HVAC pump lift is generally between 5~50m, the selection of the head is mainly to see the difference between water pressure. As head of 35m as an example, if the inlet height of 60m, so the theory of height =60+35=95m, if all pipe closed air conditioning water system, and resistance of the equipment for water is equal to the pressure difference is equal to the pump head to choose your height, and out of the water is the same, the resistance loss of lift all into the water. The calculated resistance loss is needed to pump lift. The resistance component (1) chiller resistance at 60-100kpa (2) water collector resistance in 120-200kpa (3) 20-50kpa (4) air terminal equipment body resistance is generally not less than 40kpa so 100m building the resistance calculation of estimated value = (1) 80kp+ (2) chiller resistance pipe, the collector resistance (140kpa+ 3) air terminal equipment 40kpa+ (4) body resistance 50kp=310kpa safety factor of 10% 320x1.1=341kpa H= P/ (head of pressure water density * acceleration of gravity g =352000/ (10m) X9.8 =34.8m fand) so we head for 35 meters
- Q: I have a 1969 Chrysler with a new 3 core radiator. It still has the stock water pump and I am wondering if a high volume pump would make it run cooler at higher speeds. It runs hotter when you get off the freeway. I have flushed the system and installed a new thermostat. I also replaced the fan clutch. I am at a loss of why it still runs warmer than the 180* thermostat.
- Sometimes I really wonder about Robert. Yeah, water boils at 212--AT ATMOSPHERIC pressure. But a cooling system is pressurized to RAISE the boiling point. So, ah, Robert is once again in left field. Because if you wait for it to boil over, you've probably already caused engine damage. You do NOT need a high volume pump. The 3 core radiator does NOT need more flow. The temp gauge should not fluctuate. That's the job of the T-stat--to regulate engine temp and keep it at a set point. If you're engine is getting hot at higher speeds, Check for missing baffles or cracked fan shroud
- Q: I would like to have a water pump/valve that I can tie into my house water and will run on a timer. Kind of like a sprinkler system but not so expensive an on a much smaller scale. Basically what I am trying to do is set up an auto-watering (from the tap) system for my animals when I am away for a day or two. I know this is more in the lines of a pet category but than again - not really.
- Most self watering devices for animals don't use a timer. Imagine a big coffee can with no lid, with a small hole on the side near the lip. Fill the coffee can with water, place a pie tin over the coffee can opening, and flip them both over. The pie tin will fill with water for awhile, but only until it covers the hole in the side of the coffee can. At that point, air can't get into the coffee can, therefore water can't get out of the coffee can. Your pets will drink out of the pie tin. When the water level falls below the hole in the side of the can, a little air gets in, and a little water gets out. So water will be available on demand for your pets until the coffee can is empty. A coffee can holds nearly a gallon of water, and being short and squatty your pets won't knock it over. Fun science project.
- Q: A total of three units, usually starting two units. After jumping the gate, it was like this. I haven't paid attention before. Is it a turn around?
- Only trip is not to the frequency converter settings or phase sequence change, if not moved the settings and wiring, most of the reason is the original reversal, you also know that inverter turnover also has water.Check analog positive and negative polarity, inverter settings, and if there is no problem, change the phase sequence.
- Q: Is there a way to test and see if it is the water pump that causes the car heater to blow hot air one time and then, next time it blows cold air? We flushed the heater core and did other tests, so we do not believe it is the heater core. We left the radiator cap off and ran the car (ford thunderbird..'94) for 20 minutes and watched the antifreeze level come up, but doesn't go down, not circulating. We cannot afford to go to another garage. None of them seem to know what to do anywyas and we keep paying people to fix the heater and it is not fixed. We have put two new thremostats in car, too, figuring that maybe the first one may have been faulty, but should we try that again?
- On many cars you cannot see the coolant circulating especially at idle. Just because you do not have heat does not mean the water pump, and if your car is not overheating it is probably - I say probably - doing its job. So stop putting thermostats on, probably assume the water pump is okay. So, put a thermometer into the radiator to see how hot the coolant is getting - should be ~180 degrees or so. Hmmmm - Does this car have an electronic climate control system? Perhaps that is the reason you have an intermittant problem. Assuming manual climate control - It could be a vacuum leak to one of the manual vents that is allowing cool air to mix with the hot. Or, maybe the slider from hot to cold is not working. What troubles me is the intermittant problem here. So, I will go out on a limb and say it could possibly be a bad head gasket for reasons I will not get into here. In any case, Good Luck!
- Q: Im considering installing an electric water pump in my car and i dont know much about electric water pumps yet so if you could tolerate a couple of dumb questions....? are electric water pumps reliable enough to be put into a daily driver (i just used the meziere name as an example, its the only name i am familiar with in electric water pumps)? i realise what the engine is basically done if the water pump goes.... could a change this small ever show up on either mpg or hp readings for a 200hp v6? finally, if the electric water pump just isnt worth the reliability risk, would a water pump underdrive pully do (almost) the same job of freeing work from the engine without putting the motor in harms way? thanks!
- Ls1 Electric Water Pump
- Q: A pump, the flow rate of 30T/H per hour, lift 30 meters, should be allocated more power motor?
- The actual use of power should be at least 5.5kW, I did not find 30t/H lift 30 meters of the water pump, and only he approached the model, supporting a larger power, and will not increase the power consumption
- Q: noise when i acclerate you cant hear it as much because of engine noise but when its at idle the squealing noise is somewhat loud does anyone know what it could be ? its not the water pump because i bought it new and im not overheating and the belts arent too tight either i have already checked them
- did u get a mechanic to do it? or do it your self? in case you had a mechanic do it, ask them to restoration it in case you had no issues previous. ought to be thermostat, ought to be you dont have sufficient coolant in radiator or perhaps appropriate coolant to water ratio. All i understand is you need to bleed out the radiator to get rid of all air after water pump is taken off and placed back on, because might reason issues aswell. ok nicely you in basic terms as much as date it, so i'm too, your mechanic sounds like a dumb ****, he might desire to have bled air out of radiator, the certainty he instructed you is strange, might desire to have fastened it then and there. that's an considerable step of fixing water pump. If there is air in it, your radiator and water pump wont be rotating the water correct. tell him to restoration it and say you probably did your study and you at the instant are not paying yet another cent!
- Q: Sewage treatment plant design how many pumps should be selected, head how to calculate the maximum design flow is 833M3/h
- Pump selection to consider the flow, lift, diameter and power, but also with reference to the actual workload, the design quantity is 1666, how much can actually achieve? Head to refer to pipe length, height difference, elbow number, such as flow in more than 800 of the pump, lift at 35 meters, can generally meet about 200 of the pipeline work needs.
Send your message to us
CHL/CHLKF Horizontal Multistage Centrifugal Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords