Water Pumps with Good Quality Made In China On Sale
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Specifications
1)High performance
2)Mechanical seal
3)Cast iron impeller or bronze impeller
4)Lower vibration water pump
5)Large flow
2.Packaging & Delivery
Packaging Detail: | export wooden cases |
Delivery Detail: | within 30 days once receipt of 30% T/T prepayment |
BPO Irrigation Centrifugal Split Water Pump
3.FEATURES
BPO series single-stage double-suction open type centrifugal pump self-researched by the Company after absorbed advanced technology of similar products and combined application requirement of various customers. The series pump adopts excellent hydraulic model, wider type spectrum and better structure. Pump casing is produced by special machine tool, which ensures concentricity among shaft bearing, shaft and pump case, and provides better reliability and maintainability. Apply to municipal water supply and drainage, water circulation of air conditioner, agricultural hydraulic engineering, such as irrigation, drain flooded fields etc., industrial water supply system, firefighting system, water supply and drainage of
heating system, transportation of clean water
4. OPERATING CONDITION
a)Rotate speed: 2950r/min, 1480 r/min, 980 r/min, 730 r/min
b)Flow range: 64.4~9810m3/h
c)Delivery lift: =200m
d)Medium temperature: =80 ,
e)product adopting special materials: -20 ~120
f)Ambient temperature: Lower than 40
g)Operating pressure up to achieves 2.5MPa
5. MATERIAL
a)Pump casing: Cast iron or magnesium iron
b)Pump cover: Cast iron or magnesium iron
c)Impeller: Cast iron, magnesium iron or tin bronze
d)Sealing ring: Cast iron or tin bronze
e)Pump shaft: 45# steel plated with chrome
f)Dynamic and static mechanical sea: Hard carbide, graphite
g)Configuring other material according to requirement is allowable
Rated flow | 10(m3/h) |
Rated head | 26m |
Rated power | 1.5Kw |
Voltage | 220V |
Rated Current | 7.2A |
Rated speed | 2860r/min |
Discharge diameter | 50mm |
6.Conditions of use
Pumps used in the following conditions should be continuously to work properly:
1. For water pumps suitable medium, medium temperature shall not exceed + 40°C
2. The medium PH value between 6.5 ~ 8.5
3. The volume of medium containing solid impurity is less than 0.1%, the size is not more than 0.2 mm
4. The power frequency 50 hz, voltage for single-phase 220 v, 380 v, three-phase voltage fluctuation range for rating of 0.9 to 1.1 times
5. Diving depth of no more than 5 m, is not suitable for irrigation and drainage of sewage and chemicals.
- Q: I want to put a water pump on a horse trough with the pump on the outside of the fence. There is a hose attachement at the bottom of the trough for the intake. I want to have the outake hook back to fall into the top of the water, reducing algae and eliminating mosquito larvae. I have never used a pump before. Need advice on type, size, etc. Thanks!
- Some people put goldfish in their troughs; I don't know if this is a great life for the goldfish but it would be easier.
- Q: A direct type pump model with the coupling type, what is the difference?
- This you can Baidu ah, otherwise it is not professional staff, it is estimated that will not be too clear
- Q: We have a 2001 mazda tribute that has been leaking coolant and overheating. we thought it was just the radiator, so we replaced it, but it is still doing it. It leaks pretty rapidly, and overheats pretty fast too (in 1 to 2 miles of city traffic) Does this sound more like a hose or the water pump? how difficult will it be to replace the water pump?
- Firstly follow the water to find the leak. The two problems may not be related. Assuming the radiator you bought was new, here are you possible problems/solutions. Radiator cap is a possibility. This will be apparent if you chase the leak. If you waterpump is begining to fail, you will generally have water coming from a small hole at the base of the snout where the drive pulley is (on most cars). The only way a hose can affect the ability of the cooling system to function is if the lower hose collapses when running. Check to see that this is not happening. If it is, replace the hose and make sure that the new hose has the wire coil inside to prevent this from happening. You may also have a thermostat problem. If the thermostat does not open, you will definately overheat. You cannot always check it with this method, but a good indicator is to feel the upper radiator hose before and after starting the engine (when warmed up). Before starting the engine, the hose should be fairly flexible and easy to squeeze. After starting, and being warmed up, it should get fairly stiff due to the flow going through the hose. Don't forget that the hose will be over 200 degrees, so be careful.
- Q: In 2005, the water pump, export pressure in recent years decreased year by year, the running current is increasing, there are 4 pumps are like this. Professional personnel advice please!
- The reasons are as follows:(1) motor guide bearing wear, water pump rubber bearing wear, sealing ring wearMotor or water pump bearings wear, will make the submersible pump in the machine on the wrong state of work, serious damage to submersible pumps, stator windings burned. The method is to repair or replace damaged bearings and bushings.(2) thrust bearing wear, submerged pump impeller and lower cover wearThis situation will also make the submersible pump on the machine in an abnormal state of work, serious damage to the submersible pump. The treatment method is to check the cause of the wear of the thrust bearing. Whether the mechanical seal of the shaft extension is damaged or not, which causes sand particles and impurities to enter the inner cavity of the motor, causes excessive wear of the thrust bearing. If it is caused by the mechanical seal of the submersible pump, the replacement of the thrust bearing, thrust plate and impeller, lower cover plate and other parts shall be replaced by mechanical seals at the shaft extension end.(3) the flow of the submersible pump is too large or too smallThe use of submersible pumps flow beyond the scope of use will make the motor overload of centrifugal pump or mixed flow pump, excessive flow, the pump shaft power increases, the motor overload; for the axial flow pump, the flow is too small, the pump shaft power increases, the motor overload. The treatment method is to adjust the valve properly, reduce the flow rate of the centrifugal pump or the mixed flow pump (increase the axial flow pump), and make the flow of the pump in the normal range of use.(4) the shaft of the submersible pump is bent and the bearings are not concentricThis is a serious case of submersible pumps, should be immediately overhauled, straighten the bent shaft, replace the unqualified bearings, re assembled submersible pumps.
- Q: how to replace water pump 97 pontiac bonneville?
- There's okorder /
- Q: $900 for a 96 neon but she says the water pump needs replaced.how much does it cost usually? is it even worth buying?
- While it is all apart the timing belt and tensioner should be replaced. It will cost several hundred to have it done. Neons don't get much older the 96, I would pay more like $500 for it. Make sure the head gasket is not leaking.
- Q: I am trying to replace a water pump on my ranger and i have all the bolts out. It seems to be stuck i think it is because of the oring around the outside of the pump andy ideas of how to free it?
- if all the bolts are out then take a rubber hammer and tap on it. it,s probably stuck on the gasket.
- Q: What does the lift of a pump mean?
- Lift lift height = water raise height = total lift lift height + water = water is expressed in M by H (m)
- Q: 97 izusu rodeo has constant squeal after timing belt, water pump and all belts being replaced what could be the cause. It sounds pretty bad.
- If the water pump has been replaced I would suspect either the alternator, the belt tensioner, or the A/C compressor. It's usually one of the first two and not the later, but check all three. It's an izusu so my guess is the alternator barring is worn out. Generally, In my experience, the power steering pump will not squeal unless it's ran low on fluid. The barring in the power steering pumps are usually submerged in the power steering fluid. I could be wrong but I'd check the tensioner and alternator first. Also check any idler wheels.
- Q: How much solar energy would you need to generate and run a small water pump? Say one that is big enough to extract water from a bucket that is 1 ft wide x 2 ft deep? What size solar panel would you need to accomplish this?
- Assuming you are only interested in pumping the water out of the back (and onto the floor). The majority of the energy will be consumed trying to get the water to the tip of the bucket (where it will then fall to the floor), so it will initially require very little energy, but by the time it's trying to remove the last bit of water it will have to lift it 2' high(and water exerts 2.41psi per sq. so it need to exert 2.82 PSI+force exerted by the 2' of tubing/pipe). It would also depend on how quickly you want to get the water out of the bucket.
Send your message to us
Water Pumps with Good Quality Made In China On Sale
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords