• Product list of China Engine type Generator FX340 System 1
  • Product list of China Engine type Generator FX340 System 2
  • Product list of China Engine type Generator FX340 System 3
Product list of China Engine type Generator FX340

Product list of China Engine type Generator FX340

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.Jichai diesel generator 
2.Optional alternator 
3.long-term spare parts 
4.low fuel consumption 
5.economic price 

1100kw/1375kva Jichai Reliable Diesel Generating set

 

Engine features :

1.China most famous brand diesel engine: Jichai engine 

2.Multi-cylinder in-line or veer engine,4 stork,direct injection

3.Naturally aspirated,turbocharged,water cooled or turbochaged  with air intercooler.

4.Machinery or electronic governing 

5.Fuel injection pump

6.Electric motor starting system

7.Forged steel crankshaft,cast iron cylinder and replaceable wet type cylinder liner 

8.Low discharge,and low fuel consumption

9.Installed conveniently and maintain easily

 

Alternator Features:

1.World famous brand AC alternator:Leroy Somer,Stamford,Marathon.Engga ect.

2.Brushless,4 poles,rotation magnet

3.IP21-23 enclose is standard for all industrial alternators.

4.H class insulation system

5.AVR self-regulated,voltage regulation rate:±1%

6.Simple installation and maintenance with easy easy access to terminals ,rotating diodes and coupling bolts.

7.Moisture proof,sand-proof,dustproof ,salt-proof and vibration-proof.

 

Control system:

1.a) Automatic alarm system:the unit has the acousto-optics alarm system and arrestor for any situation as the start defeat,the water is over temperature,

the oil pulls down ,over speed,over load and over current.

  b) Operation display:

    i)Unit voltage,tri-phase load current and frequency display

ii)Water temperature .oil pressure display

iii)Fuel level, fuel temperature display

iv)Audible and visual alarm lamps and buzzers

2.Starting system:DC alternator is used to start engine.

3.Short circuit protection :MCCB air switch

4.Cooling system:combined cooling water tank fitted to meet the requirement of radiation at ambient 

temperature 40°C

5.Filter system:oil ,fuel and air filter

6.Accessories:exhaust elbow,below,muffle

ModelOutput POWER(KW)Engine ModelEngine Power
PRIMESTANDBY
FX340
45340SC4H95D262/68
Q: gas is too expensive. here in florida i guess everyone has a noisy gas powered generator for when hurricanes knock out our power
I would suggest using a set of solar panels that will supply enough power to run the fridge and a bit more, with a battery storage to get through the night. This can get you through months of power outage. It will be much more costly than a gas generator to provide the same emergency coverage. But you do not use it just for emergency. It provides that power year round for 20+ years, cutting your electric bills. This is not a lot cheaper than just paying your electric bills. If you get the best, most cost effective solar panel system it will be a break even compared to the electric company.
Q: I am interested in what are the inherient differences and what are the different sets used for?
both. ac or dc depends on your needs. do you need a 28 volt 500 amp generator (thats DC) for running Dc motors. Ususally for small purposes its an AC generator putting out say 6000 watts at 120 VAC or 240 VAC at 60 Hz or 50 Hz depending which country you live in or generator came from. Also along with the AC it puts out, it also has an output of 12 volt DC for charging batteries, even its own, for starting itself,like a car. DC generators of any size is for mostly for welding as the last link shows you one and a picture
Q: avr is automatic voltage regulator for power generators
If you mean the build-in pcb of a fuel/diesel generator which build-up voltage initially and then keep it stable under any load, then read this: First you need to see your generator minimum requirements to determine specs of AVR. You will probably found a label on generator with those Information: Ex. volt (maximum excitation voltage) Ex. amp (maximum excitation amperage) Your AVR output must exceed those specs. If generator is brushless type in most cases it does. Also input voltage of AVR must be the same as output of generator (ex. 110V110V, 220V220V). If generator is triple phase then you can do the same (ex. 380V380V, 440V440V) but if generator have output in star formation then you can use node for a smaller voltage of AVR (ex. 380V220V, 440V253V). If generator work in parallel operation (usually marine main generators does) then things get complicated. In this case AVR is good to support current transformer to make generator more elastic under load fluctuations and match other generators in the same circuit.
Q: i have 45 kva Perkins diesel generator cranks, battery is ok,does anybody know why the engine doesn't start?every think looks clear!!!please help!!!
Good, a general diesel engine similar to a Lister-Petter naturally aspirated will produce about 20 HP for an hour from one gallon of diesel. You will have acquired a few 45 gallon tank and about 28 horsepower. I`m no longer going to get my calculator out presently of night however i might advise that it might well run for 33 hours at full chat, but when the weight on it is small then greatly longer because it runs at consistent revs regardless of load, except the load is immoderate. As another be aware; A two stroke petrol is considered to produce 10 HP per hour per gallon. A 4 stroke petrol is regarded to supply 15 HP per hour per gallon. A gallon is 4.Fifty four litres. Engines with turbos equipped are an utterly exclusive story, as are latest lean burn engines. Hope that helped, high-quality of luck, Bob.
Q: I own a 2300 square foot home with an upstairs and downstairs heatpump. If I wanted to buy a generator to use in the event my power went down what size should I shoot for. I would like to be able at a minimum to provide upstairs heat (1000 square feet), maintain the fridge and provide minimal light at night. Basic survival type stuff. Also how much fuel would normally be consumed running for 24 hours?Thanks I know this is vague so generalities are fine.
The whole key to this answer is fuel. If you live where you can get lp or natural gas to the house then go with the generac whole house with automatic switch. I mean a constant supply like city gas or propane. NOT FROM A TRUCK. The trucks will not run if your in the middle of a hurricane or other types of storms If you have to use propane from a tank, rent the largest one available. A 300 pound tank will only last 4 days under full load. Gasoline is dangerous and to hard to keep fresh.
Q: If you were talking on the phone to someone and dropped the phone into a bathtub filled with water would they get electrocuted? Does it matter if it's wireless or not?
Hold on gang.she asked if they would get shocked. Do you mean the person being spoken to by the person who dropped the phone? If so, the answer is no. A shock occurs when your body connects a source of electricity and the ground. The person you're speaking to is not in the path that the electricty takes to ground even if the devices along the wire would permit the transmission.
Q: i have Diesel generator100KVA , how many air conditioner of 2 tons (i phase)i can use with this generator without overload
you need to look at the power requirements of the air conditioner of 2 tons it should indicate it's power requirements.
Q: I have a small one bed one bath home probably not over 1000ft what size portable honda generator should I buy?
add up the wattage of the appliances you want to run and get a generator a little bit bigger. the size of the house is not the issue. the issue is what do you want to run power to.
Q: I have two deisel engines and two tank feeds, how can I connect the genset (4KVA) . I am conerned when the engines are idling or even running they will start the genset. I do not want to put an extra tank.Thank you
If your tank has another port on it for a fuel line that is where you hook up. If not go to the supply line at the tank and put in a T fitting and then a shut off valve for each engine. Run the supply line to the generator from that T. You will also need a return line from the generator that you can T into at the return line from the engine at the tank. Many people that convert from gas to diesels run into these same problems. Often a fitting is made up that is put in the fuel fill line to allow for the return line. The generator supply and return lines will be smaller then the engine fuel lines. Running the engines will not cause the generator to start.
Q: i found a 1998 dodge ram 2500 with turbo diesel Cummings motor, and people tell me that Cummings is the best to get why is that? would $3300 be worth it for this truck?
well the Cummings engine is used in semi trucks but are compact to fit into trucks. the turbo is in all of the trucks so when you hit a certain speed it will kick in. my dad tried to race one in his work van but when the turbo kicked in the power was to much and the truck was all over the road. but these trucks have better gas mileage and last longer which increases its value.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords