Pipeline Ball Valve-Reduced Bore High-Performance DN 14 inch

Pipeline Ball Valve-Reduced Bore High-Performance DN 14 inch

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
100 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

pipeline ball valve-reduced bore High-performance

Product Description of High-performance pipeline ball valve-reduced bore:

 High-performance pipeline ball valve is Raymond(RMD)hightech products,as switch control equipment,it is mainly used in natural gas,oil,gas,liquefied natural gas pipeline transmission system and other industries,its anti-sulfur products containing hydrogen sulphide,impurities and high corrosion are suitable for the long-distance natural gas pipeline.

Design Features of High-performance pipeline ball valve-reduced bore:

Body of high-performance pipeline ball valve is forged structure.The connection type for body and vice-body can be BB(bolted connection)and WB(welded connection).The WB(welded connection)and the LWB(Fully-welded extended stem)structure isadopted for buried ball valves,as shown below.
High performance pipeline ball valve series has the feature of strength, high perfect sealing, maintenance-free, long life and so on. The production of this series ball valve adopts the international advanced ball valve design and manufacturing technology, selects high-quality materials in accordance with the standard selection of materials and combines with advanced materials forming forging technology. At the same time, with the years of ball valve design and manufacturing experience, the use of advanced processing and manufacturing equipment and production and processing technology, through the first-class inspection and testing equipment and instruments, perfect quality assurance management system and excellence in the production of high-performance philosophy can ensure the quality of valves. This series of valve has the performance of a high strength, defect-free forging body, excellent sealing performance, even at maximum pressure difference(full pressure),it will still be able to ensure that seal without leakage, after frequent switching action to realize a safe usage in the transportation of oil, natural gas, coal gas, and other special medium transportation pipeline.

The special structure of valve seat seal of High-performance pipeline ball valve-reduced bore:

Floating structure means seat reciprocally can move along channel direction,so as to guarantee the ball and seat are tightly sealed.
(
)Valve seat structure suitable for different occasions and sealing requirements
Valve seat can be designed as a standard single-piston effect and specific dual piston effect,Figure1 shows single-piston effect-inletside seal;Figure2 shows Dual Piston effect-outlet-side seal;Figure3 shows special dual piston effect sealing structure
(
)Multi-level structure of the valve seat seal
As shown in Figure4,there are two elastic O-ring in the valve seat ring-ring A and ring B.Sealing ring A spring-loaded through the valve seat so that the sealing surface of sealing ring A tightly fit with ball surface to form an initial seal.When there is pressure in the system medium,the piston force
produced by the piston force produced by the piston effect of size difference makes elastic deformation of the ring A Ershi sealing surface and ball more closely fit the surface to form a re-sealing;meanwhile,due to ring A in the medium resulted in elastic deformation under pressure so that the sealing ring B is also closely fit the surface of ball for the formation of the second stage seal.When the system medium pressure increasing,it will have an enormous pressure in the valve seat ring A and ring B,so that the two seals have a greater elastic deformation,and then the metal valve seat ring surface and the ball surface sealing together to form a third level of metal to metal seal.
(
)The assisted valve seat sealing equipment
Based on the actual service condition,medium requirement,sealing requirement,etc.,the assisted valve sealing equipment will be considered to be necessary or not.The assisted valve sealing equipment is a one-way valve installed outside of valve body that can prevent medium leakage and can inject sealing grease into valve body by external force.When the assisted valve seat sealing equipment is required,valve seat ring shall be design and processed with injection grove and hole to connect the assisted valve seat sealing equipments.Such equipment can prevent the medium by the sealing of injection of rease.Refer to Figure5 for reference.

Pipeline Ball Valve-Reduced Bore High-Performance DN 14 inch 

Multi-level structure of stem sealing 
Figure6 shows the stem multi-level sealing by adopting"O"ring,flexible graphite and grease injection;"O"ring achieves the first level stem sealing;Replaceable flexible graphite realizes the second level sealing by the compression of packing sleeve and packing flange;And the third evel sealing is realized by installing assisted sealing injection valve to the packing box,and by designing with the injection groove and hole to connect with the stem injection valve,which can inject grease.

 Pipeline Ball Valve-Reduced Bore High-Performance DN 14 inch

Unique and safe seat structures of High-performance pipeline ball valve-reduced bore:

Ball valve fireproof design is implementation of the API607,API6FA standards.According to service conditions and user requirements,ball valve can be designed as a fireproof structure.
(
)Fireproof structure of seat
As shown in figure7,there is composite fireproof ring,which are combined with graphite and stainless steel wire in the seat.Once the soft ring is burnt out in case of a fire,the fireproof ring and seat ring will form a piston structure through the spring to load the valve body.That will push and closely contact the metal seal surface of the seat ring to the body surface,So as to prevent a lot of medium from leaking from the burnt place of the seat ring,and prevent the fire from expending.

 Pipeline Ball Valve-Reduced Bore High-Performance DN 14 inch

()Fireproof structure(body and bonnet)
The seal gasket for bolt connecting valve body and valve bonnet,are used fireproof stainless steel wire and flexible graphite gaskets.Gasket compression load through the bolts and ultimately,ensure the valve body and valve cover between the metal to metal contact,so that the valve can with stand more high load,but also improve the fire safety of the valve.But for the full welded ball valve,the valve body and cover is welded structure,that fundamentally eliminate the possibillity of leakage of the valve housing.Even in the case of fire damage,there will be no leak.
(
)Fireproof structure(body/packing and stem)
The body and packing connection gasket adopts fireproof stainless steel wire and flexible graphite gaskets.The stem packing adopts flexible graphite to ensure no leakage in case of fire.

 

Pipeline Ball Valve-Reduced Bore High-Performance DN 14 inch

Pipeline Ball Valve-Reduced Bore High-Performance DN 14 inch

Standard of High-performance pipeline ball valve-reduced bore:

Design Standard

 API 6D customize 

Connection Standard

 ASME B   16.25-2007  ASME B 16.5  ASME B 31.4  ASME B   31.8  DIN  GBGB/T  JBJB/T JIS customize   

Test Standard

 API 6D customize 

Face to Face

 API 6D customize 

Pressure-temperature rating

 ASME B 16.34-2004 customize   

Marking

 MSS SP-25 customize 

FAQ of pipeline ball valve-reduced bore:

Q1:I can’t find the type of steel check valve which I need. what can I do?

The chart above only lists out some common composition of steel check valve parts.We may provide other different parts material composition according to the customer's request or the actual valve working condition.

 

Q2:Which certification do your products pass?

  Our products are in accordance with ISO 9001ISO 14001API 6AAPI 6DTS CEAPI607/6FA/BS6755.

 

Q3:How can I place an order?

  The only one thing you should do is to tell us the sepecification about type quantity and  mode of transportation, then we will send you quotation within 24 hours.


Q: Is there a more technically correct name for a valve that slowly opens, allowing increased pressure in a water line without blowing the end off?
I've always known them to be simply called motorized valves, but they aren't specifically made to prevent instantaneous pressure build up. They are usually installed as a convenience type of thing and in lieu of solenoid valve which WOULD be an almost immediate full pressure situation, but any valve other than a solenoid activated one will allow for slow build up of pressure. A motorized valve just lets you do it automatically and you don't have to be right at the valve location to open it. Al
Q: For example, 2 valves from the modular 4.6 is equivalent to 1 valve from the LS1 which is a bigger valve.
OHC generally have 2 small valves instead of 1 large valve operated by a push rod. The aim is to have the most flow possible and the least mass of valve. (avoid valve float) I cannot say anything about specifics
Q: I have a 96 Toyota Camry. I am putting about 4 qts. of oil in it a month. Other than this issue and some other minor things this car is in great shape. It doesn't appear to be smoking from the tailpipe and I never find any puddles of oil under the car after it has been sitting in one place for a while. What can be wrong with my car causing it to eat this much oil. Every now and then I smell a little burning oil but it is not coming from the exhaust. I'm thinking a valve job. Engine has 250,000 miles on it and it runs great other than the oil thing. I drive it 116 miles a day back and forth to work. Any suggestions??? Help!!!
A valve job is removing the cylinder head(s) from the engine so the valves, guides and seats can be refurbished to restore compression and oil control. A valve job may be necessary by the time an engine has 80,000 or more miles on it, or to fix a burned valve, compression or oil burning problem. If the valves are to be reused, they will be inspected, checked for straightness then refaced. Many shops automatically replace all the exhaust valves to reduce the risk of failure (exhaust valves run much hotter than intakes and are much more likely to fail). On the other hand, if you have an import car with dual overhead cams, four-valves-per-cylinder and a lot of fancy valvetrain hardware, you might be looking at a total bill of $200-$300. Parts typically cost much more for import engines as well as performance engines and diesels. The labor to do the valve work is also much more involved on these overhead cam multi-valve heads. (Of course, they didn't tell you that when you bought the car. All they stressed was the fantastic performance of overhead cams and multiple valves.)
Q: I recently adjusted the valves and put new valve covers on my bug and now I have a leak around the fron corner of one of my valve covers. What happened? What can I do?
new seals + get rid of the cheapo chrome repros and put OEM covers back on.
Q: I have rented a house and the irrigation timer only has wires of one zone.It goes to a single valve then out to a big round cover with 6 zone pipes coming out of it. What the heck kind of set up is this?does it do a mechanical rotation inside that cover? the zones only come on one at a time but every time I turn it on I get a different zone as they are all Zone 1 on the timer.
The okorder / Please provide pictures if you can, and i can expand more on helping you figure this out.
Q: Electric Hot Water Tank Pressure Release Valve Leaking, Why?
Michael is correct here. The TP valve is an integral part of the unit and should be replaced if leaking, not merely flipped open and closed a few times and then forgotten. Besides the folks that are telling you to flip the lever open and closed are forgetting about shutting down the water supply first. If you don't shut off the water before doing this you'll have a fair amount of hot water splashing out on the floor, and if it's overheated water it could very well scald parts of your body. It's extremely dangerous to take the advice of strangers, on a forum such as this, about something like this that can cause you much trouble and grief. If you are a handy person it's a fairly simple repair to replace one of these. Just turn off the water supply valve to the tank, if it's separate, if not then shut down the house supply. Many people say you need to drain water off the tank so as not to get any on the floor, and if that's a big concern, then it's not a bad idea. However, once the water is cooled, with the supply shut down there's no more pressure and the tank is similar to a straw full of water with your finger over the top. The water won't flow out easily without an air supply above it. So, if you have your pipe wrench ready and can take the old valve loose, have the new one taped with teflon tape on the threads and ready, when you unscrew the final threads of the old one, stick the new one right into the hole and thread it in. You won't lose enough water to be concerned about and you'll have a new pressure relief valve in place. Be sure to tighten it down good. Refill whatever water has left and check for leaks.
Q: I'm thinking about getting a Cold air intake along with a Bypass Valve to prevent Water Indigestion on my Toyota Corolla 07. I was wondering if Bypass Valves actually work and can someone explain to me the physics around it???( How bypass valves work)
Air Intake Valve
Q: I had to replace the gaskets on my valve cover only to discover that the valve cover had developed a hole due to oxidation. I waited a week for a new valve cover to come in and left the engine exposed. Should I have any issues? I mean its covered but its still outside. Should I pour some oil on the exposed part of the engine?Its been already about a week.
yea it will be fine as long as you check the level and watch for bubbles of water on the dipstick after running it a bit, just change the oil and filter to insure you don't water foul a plug
Q: I was diagnosed with a VSD and a Biscuspid Aortic Valve and my doctor has started hinting towards sugery. I found out that the only reason i haven't had surgery yet is that it is stable enough to wait until technology improves so i am not left with a large scar. i was just wondering what this surgery would entail and if anyone has had it. I am 19 years old and kind of worried about it...
VSD or ventricular septal defect is a congenital disease caused by failure of your ventricular septum to fuse with the bulbar ridges of your atrial septum during embryogenesis. Some VSD are fine since only a small amount of blood is shunted from LV to RV but a majority is still shunted straight to the aorta. An aortic valve stenosis which I think is what you are referring to is usually an adult disease associated with rheumatic fever, mechanical breakdown from hypertension, or death from an MI. Aortic valve stenosis is a bit more worrisome since this can lower the output of your heart by acting as an obstruction, which overtime can cause ventricular hypertrophy, a disease with whole set of other problems. New trends in VSD repair uses minimally-invasive surgery using a transcatheter that is inserted esophageally or through femoral artery; very small scars and short recovery time. Aortic valve repair may also be done this way in the future, but if your aortic valve is still patent, there is no need to replace it at this moment because it would require a donor and open heart surgery.
Q: My pressure reducing valve (or restricting valve) was looked at by three master plumbers and they all said I need a new one. My water pressure has been low for weeks. It measures about 100 psi at the outside hose bibs, but it is very low inside and suddenly reduces after you turn on the facets inside. The shower is ok. My automatic sprinkler system is not able to work now due to low pressure. A relative of mine thinks we can just add a handle (as one is missing) on the valve and adjust the pressure ourselves. The repair of the valve is around $500-600! I am told in Texas that we have to have a permit and inspection to repair this valve. Also I was told by the last plumber that came out, that I have to install a expansion tank on my new hot water heater according to code. I'm not sure if that is a city code or federal. Please respond as to information you may have on this problem. The expansion tank is required I'm told when you have a pressure reducing valve for safety, is this true?
The cost you quoted seems a bit high to me. Mine didn't cost anywhere near that amount in East Texas. A pressure reducing valve acts like a check valve when there is no flow. That is it closes as the pressure rises when you are not using any water. In this condition, the hot water heater can raise the pressure even higher since there is no place for the expanding water to go. That is the reason for the expansion tank. Without the expansion tank the pressure relief valve on the hot water heater can relieve unnecessarily or weep a bit.