Perkins Genset Diesel Generator Small Portable 100kva With Three Phase
- Loading Port:
- Guangzhou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Perkins Genset Diesel Generator Small Portable 100kva With Three Phase
Quick Detail:
1.Perkins water cooled Diesel engine:403D-11G,403D-15G.404D-22G
2.AC Alternator Brand:stamford,leroy somer,marathon
3.three phase four wires,50Hz/60hZ,220V/380V
4.deepsea,smartgen Digital auto-start panel
5.noise level:70dBA at 7m away
Genset Features:
1. Genuine UK industrial diesel engine
2. Radiator 40°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
9.Mould case circuit breaker
10. 24V DC start motor and storage battery
11. 24V charge alternator
12. 24V batteries, rack and cable
13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler
14. Comply with ISO and CE standards
15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Engine Features:
1. Genuine UK Perkins industrial diesel engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption
9. Installed conveniently and maintain easily
Alternator Features:
1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA
2. Brushless, 4 poles, rotation magnet
3. IP21-23(NEMA1) enclose is standard for all industrial alternators
4. H class insulation system
5. AVR self-regulated, voltage regulation rate: ≤±1%
6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts
7. Wide range of flange adaptors and single bearing disc coupling
8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528
9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof
Digital Control panel
Controller Brand: Smartgen, Deepsea,ComAp
Control Panel: English interface,LED screen and touch buttons.
Main Functions:
1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.
2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.
3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown
Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. Excellent Access for Maintenance
5. Security and Safety
6. 1m<80DBA / 7m<70dba< span="">
Optional:
1. Trailer type
2. Soundproof / water proof
3. ATS (automatic transfer switch)
4. Parallel system
5. Remote system
PMC System:
1. Standard 23 pitch windings avoid excessive neutral current
2. Permanent magnet generator system provides constant excitation under all condition
3. Optional accessories available for easy paralleling with mains or other generators
4. AVR auto voltage regulation, auto exciter, auto adjustment
Specifications:
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRP10 | 7 | 9 | 8 | 10 | 403D-11 | ≤252 | 3 | 1.131 | 77*81 |
GNRP15 | 10 | 13 | 12 | 15 | 403D-15 | ≤264 | 3 | 1.496 | 84*94 |
GNRP23 | 16 | 20 | 18 | 23 | 404D-22 | ≤243 | 4 | 2.216 | 84*100 |
GNRP33 | 24 | 30 | 26 | 33 | 1103A-33G | ≤210 | 3 | 3.3 | 105*127 |
GNRP50 | 36 | 45 | 40 | 50 | 1103A-33TG1 | ≤212 | 3 | 3.3 | 105*127 |
GNRP65 | 48 | 60 | 52 | 65 | 1103A-33TG2 | ≤211 | 3 | 3.3 | 105*127 |
GNRP73 | 52 | 65 | 58 | 73 | 1104A-44TG1 | ≤207 | 4 | 4.4 | 105*127 |
GNRP88 | 64 | 80 | 70 | 88 | 1104A-44TG2 | ≤213 | 4 | 4.4 | 105*127 |
GNRP103 | 75 | 94 | 82 | 103 | 1006TG1A | ≤210 | 6 | 5.99 | 100*127 |
GNRP150 | 110 | 138 | 120 | 150 | 1006TAG | ≤205 | 6 | 5.99 | 100*127 |
GNRP165 | 120 | 150 | 132 | 165 | 1006TAG2 | ≤205 | 6 | 5.99 | 100*127 |
GNRP225E | 165 | 206 | 180 | 225 | 1306C-E87TAG3 | ≤220 | 6 | 8.7 | 117*136 |
GNRP250E | 180 | 225 | 200 | 250 | 1306C-E87TAG4 | ≤219 | 6 | 8.7 | 117*136 |
GNRP259E | 188 | 235 | 207 | 259 | 1306C-E87TAG5 | ≤221 | 6 | 8.7 | 117*136 |
GNRP275E | 200 | 250 | 220 | 275 | 1306C-E87TAG6 | ≤223 | 6 | 8.7 | 117*136 |
GNRP344E | 250 | 313 | 275 | 344 | 2206C-E13TAG2 | ≤201 | 6 | 14.6 | 137*165 |
GNRP388E | 280 | 350 | 310 | 388 | 2206C-E13TAG2 | ≤198 | 6 | 14.6 | 137*165 |
GNRP450E | 320 | 400 | 360 | 450 | 2206C-E13TAG3 | ≤201 | 6 | 14.6 | 137*165 |
GNRP500E | 360 | 450 | 400 | 500 | 2506C-E15TAG1 | ≤216 | 6 | 15 | 137*171 |
GNRP550E | 400 | 500 | 440 | 550 | 2506C-E15TAG2 | ≤211 | 6 | 15 | 137*171 |
GNRP625E | 450 | 563 | 500 | 625 | 2806A-E18TAG1A | ≤196 | 6 | 18.13 | 145*183 |
GNRP700E | 508 | 635 | 560 | 700 | 2806A-E18TAG2 | ≤203 | 6 | 18.13 | 145*183 |
GNRP800 | 580 | 725 | 640 | 800 | 4006-23TAG2A | ≤199 | 6 | 22.921 | 160*190 |
GNRP900 | 640 | 800 | 720 | 900 | 4006-23TAG3A | ≤200 | 6 | 22.921 | 160*190 |
GNRP1000 | 720 | 900 | 800 | 1000 | 4008-TAG1A | ≤206 | 8 | 30.561 | 160*190 |
GNRP1125 | 818 | 1022 | 900 | 1125 | 4008-TAG2A | ≤208 | 8 | 30.561 | 160*190 |
GNRP1375 | 1000 | 1250 | 1100 | 1375 | 4012-46TWG2A | ≤212 | 12 | 45.482 | 160*190 |
- Q:Why does the direct start-up of high power motors affect the voltage of the grid
- Because the instantaneous starting current of the three-phase machine is five to seven times the rated electric current, the voltage of the line is reduced, and the voltage of the power grid and the zhou wave are low. Therefore, the high power motor should be initiated by star/Angle to reduce the starting current and avoid the large fluctuation in the voltage of the grid. The star triangulation is initiated by changing the connection of the motor winding, and the pressure is actuated. When activated, the main contactor will give the power to the three ends of the motor winding, which will close the three ends of the motor winding. Winding becomes a star connection, after the completion of the start, time relay action, star contactor disconnect, contactor operation will be three of the power supply to the motor winding end. The winding becomes a delta connection. The motor is fully pressed. During startup, the asterisk contactor and the operating contactor must be interlinked. Image: KT - time relay, KM1 - star contactor, KM2 - the main contactor, KM3 - the operating contactor.
- Q:Are motors and motors a concept?
- A device that converts mechanical energy into electricity. Currently, the majority of consumer power is consumed, so the commonly used motor is basically the motor.
- Q:If the speed of a normal motor is adjusted by the frequency converter, the speed can exceed the rated speed, and if the current power is above the rated speed, what is the change in current power
- It can exceed the rated speed, but it is best not to be too much, the main fear is that the bearing and rotor will not bear the high speed. The motor exceeds the rated speed, the output of the motor is constant, but the torque decreases. Can you continue to drag your load, depending on whether your load is constant or constant torque,
- Q:What is the meaning of the motor from cold and cold?
- Self-cooling is an unsubsidized cooling device that allows the heat to spread through the air or other media. Strong cold is forced cooling, with auxiliary heat sinks, keeping the temperature within a certain range
- Q:The difference between ordinary motor and permanent magnet motor
- There are two different kinds of classifications that you can't compare. Permanent magnet motor is called permanent magnet motor, not permanent magnet (electromagnet) for permanent magnet. Dc motors with direct current, no direct current (alternating current) is ac motor. A permanent magnet can be a dc motor or ac motor (for example, a home breeze fan). In the same way, no permanent magnet can be either a dc motor or ac motor, or even an alternating current.
- Q:Does the frequency conversion machine speak louder than the ordinary motor?
- This is not necessarily, the power of the motor size, also related to the noise of the motor itself, but in the case of the same parameters, the inverter will make voice be larger than ordinary motor, because through the inverter output waveform directly contains a large number of higher harmonic,
- Q:My electric motor with riding a motor won't turn, idling did not move, I thought that the controller has broken a new motor does not turn other are thoroughly headlight electricity for electric machine does not move
- I thought the controller broke a new motor and didn't turn????????? It's strange that the controller has broken a new motor. Are you in the water?
- Q:What is the difference between an energy-saving motor and a general motor
- Features of high efficiency energy-saving motor: 1, save energy and reduce long-term operation cost, very suitable for textile, fan, water pump, compressor, power saving a year recoverable motor acquisition cost. The machine can be switched on and off, and the asynchronous machine can be replaced completely. 3, rare earth permanent magnet high efficiency and energy saving motor itself than ordinary more than 15 ℅ save power. The power factor of the motor is close to 1, improving the quality factor of the power grid without the power factor compensator. Small electric current, saving power distribution capacity and extending the overall operating life of the system.
- Q:The difference between the frequency converter and the ordinary motor
- There is no difference between the motor and the motor of the converter is the three-phase asynchronous motor. However, the speed of the machine can be adjusted to achieve energy saving and constant pressure.
- Q:What is the difference between the two class motors and the four-stage motors?
- But, in fact, if the rotor is as large as four pole rotor between, each of the four pole rotor pole, relative only half of the poles, so Br also approximately half, almost the whole torque.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Perkins Genset Diesel Generator Small Portable 100kva With Three Phase
- Loading Port:
- Guangzhou
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords