• Generator sets Factory price china yuchai diesel -150kw System 1
Generator sets Factory price china yuchai diesel -150kw

Generator sets Factory price china yuchai diesel -150kw

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
300 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Place of Origin: Jiangsu, China (Mainland)

  • Brand Name: yuchai

  • Output Type: AC Three Phase

  • Speed: 1500/1800rpm

  • Frequency: 50/60hz

  • Rated Power: 20-1000kw

  • Rated Voltage: 200-1-440v

Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.

 

YUCHAI SeriesPower(KW)Power(KVA)Jichai Engine ModelCylinder NO.Fuel consumption
g/kw.h
DimensionL*W*HWeight  
 KG
FKS-Y181822.5YC2108D2≤2251700*700*1000650
FKS-Y242430YC2115D2≤2201700*700*1000650
FKS-Y303037.5YC2115ZD4≤2051700*750*1000900
FKS-Y404050YC4D60-D214≤2051800*750*1200920
FKS-Y505062.5YC4D85Z-D204≤2001800*750*1200950
THY-646480YC6B100-D206≤2052250*800*13001200
FKS-Y757593.75YC6B135Z-D206≤2022250*800*13001250
FKS-Y9090112.5YC6B135Z-D206≤2022250*800*13001300
FKS-Y100100125YC6B155L-D216≤2002300*800*13001500
FKS-Y120120150YC6B180L-D206≤1922300*830*13001600
FKS-Y140140175YC6A210L-D206≤1922300*830*13001700
FKS-Y150150187.5YC6A230L-D206≤1922400*970*15002100
FKS-Y160160200YC6G245L-D206≤1952500*970*15002300
FKS-Y180180225YC6L285L-D306≤1972600*970*15502500
FKS-Y200200250YC6M350L-D206≤1973100*1050*17502750
FKS-Y220220275YC6M350L-D206≤1973100*1100*17502800
FKS-Y280280350YC6MK410L-D206≤1953200*1150*17503000
FKS-Y300300375YC6MK470L-D206≤1953200*1200*17503100
FKS-Y320320400YC6K500L-D306≤1953250*1200*17503200
FKS-Y350350437.5YC6K550L-D306≤1953250*1250*17503250
FKS-Y350350437.5YC6T550L-D216≤1953300*1250*18503500
FKS-Y400400500YC6T600L-D226≤1953400*1500*19703900
FKS-Y440440550YC6T660L-D206≤1953500*1500*19704000
FKS-Y500500625YC6T755L-D206≤1954000*1500*20005000
FKS-Y650650812.5YC6C1020L-D206≤1954500*1800*25007500


Q: I recently purchased a portable generator that is 7 hp and 3050 continuous watts, i tried to calculate the efficiency as follows:743 watts 1 hp7 X 743 5201 watts, (so at 100 percent efficiency, 5201 watts is possible to produce from a 7 hp generator.)the unit produces 3050 watts, so the 5201 watts (possible watts)/3050(actually produced watts) (0.5864) or approximately 59% efficiency, this does not seem right, it should be about half that.What am i doing wrong?
First, nothing operates at 100% efficiency. You are converting angular rotation into electric power and in any conversion of power, you lose efficiency. 59% efficiency isn't that bad. Second, generators are measured at continuous power and peak power. Check your owners manual or look on the side of the generator. At peak power, you will find that the efficiency is greater.
Q: ie a ships diesel generator.
I'm assuming by trip you mean shut down/off Plenty of reasons: 1) overheat, most common cause, could be lost water pump or water supply or cooling lines plugged 2) electrical, although diesel does not use sparkplugs there are electrical components. There are glow plugs that get the whole process started when cold, there is a starter motor that gets it all going and there is some method to keep the fuel warm enough to flow correctly 3) Starve for fuel, either fuel ran out, to low temp so its sludge 4) Loss of oil pressure that is used for lubrication 5) Ouput limits, there will be an overcurrent/overvoltage system regulating the output of he generator and if it gets really out of wack then it will kill the whole thing to prevent damage to everything That's all I can think of right now
Q: Hi GuysOkay i have been given the task of fitting a 240v generator to an RV in to one of it's closet spaces.It needs to power one 240v socket, charge the RV battery (standard battery on trickle charge) and power the shower which doesn't have a boiler as such it heats the water on a 'as and when' basis. Low wattage lighting also two 40W lightsThere is plenty of space. so I thought how about try and fit a generator than runs on renewable energy.I just need to know what direction I should be looking in. HydrogenSolar (Doubt it)Bio-FuelAnything else?Also, is it best to convert an existing design of generator, buy a new one or build one from scratch to fit?Any help would be truly awesomePeace
Electric heating of your hot water is very inefficient since you have so much heat rejected in the exhaust for every KWHr you make. Your best bet would be to use the exhaust heat and/or jacket cooling water from a biofueled generator to heat the hot water tank. You get very high efficiencies from that combination. I have seen such devices talked about (see the link below) for years, but have recently seen one that is actively under development. It may be a bit oversized for your RV, however, since it is for a house. You may be able to just add a heat exchanger on the exhaust and use a small, thermostatically controlled pump to circulate the hot water from the tank through the tubes. Biofuels are not as available as gasoline, but if you research where you are going, you may find they are more prevalent than you think. Also, the generator will be able to run on fossil fuels as well, giving you a back up in case you can't find biofuel. Hydrogen is interesting, but I can't think a commercially available generator that runs on it. And you would still have the efficiency issue unless you recovered the exhaust heat like I have said for the biofuel. I can't think that solar would work well, you have such a limited amount of collection surface on the roof, and lugging around batteries and/or hot water is also inefficient. I have been on trips where it was cold and cloudy for a week, solar would not do well under those circumstances.
Q: Also would i be safe 20 miles away from the power station if any things happened. I am talking about the power station Dungeness B in Kent England. also if anything were to happen how long would i have to get out of the radius of the station.
i could have theory that nuclear capability stations are completely automatic and could proceed produceing capability till the two the gasoline rods are spend or between the structures encounters an errors and shuts its self down. If some thing grew to become into to ensue to the cooling structures although earlier the gasoline grew to become into spent you are able to have a soften down on ya palms !
Q: i have a 7.5 onam diesel generator that runs for 15 min and shuts down i get a code 33 (overheating)I change coolant,cap and thermostat also checked air flow Still no luck.any ideas anyone
If it has a waterpump you might need to change that.
Q: Hello,I'm doing a research project that requires me to report on five ethical missteps made by engineers/staff at the Fukushima plant that caused the disaster. I'm having trouble with this research because most of the information i'm finding centers around the earthquake and subsequent tsunami that caused so much damage.Can anyone point me toward any human errors that centered around poor ethical judgement?
If you just google human error fukushima you're going to get (a) a few articles from the summer of 2011; (b) a rash of articles from July, 2012; (c) a rash of articles from Oct-Nov, 2013; and (d) a rash of articles from last week (Feb 2014). Whether all will cite ethical missteps is unknown to me.
Q: Hi -- looking for specifically Lister Petter Diesel Generator parts distributor in central Cal. Electrical parts -- cycle timers, a/c disconnects, etc.,. The main company (ListerPetter)is closed until after the 5th, and this machine powers my home, in the process of battery conversion project, and looking to finish this project between th holidays. THis is my hubbys endeavor -- I am just the messenger -- so I hope these questions make sense, please feel free to email me more details or anyhelp you think useful. Thanks everyone
Depending on where you live try the on line yellow pages. Especially in large farming areas, like Fresno or Bakersfield, Stockton etc. Their will be equipment parts shops that will help you find what you need if they do not have it.
Q: Have a 15kw generator. Diesel. I want to upgrade without buying a whole new generator. Can I keep the motor and swap a generator hook up
The power of the diesel is matched to the electrical power rating. In theory, the Diesel requires 21hp to drive a 15kW output and is actually 25 (or more). The Diesel cannot deliver more electrical power. The oversizing of the prime mover (diesel) helps to absorb starting loads and prevent full throttle operation at rated output. In addition, specific exciter voltage is often drawn from the engine. The bell housing and couplings which join the engine to the generator are also likely to be specific. The chances of DIY improvement a slim.
Q: I figured it might be diesel generators but I wonder how all that works. I am curious person. LOL
Yes there are usually several diesel generators to supply electricity. On older vessels a steam turbine drove a generator for power.
Q: I want to shut it inside a small room, but will it not suffocate ? Which part of the gen set should be moved out of the room ?
The size is relevant. Is this a small portable set for homes, or a large stationary unit for a building. I'll assume the latter. Enclose it in a sound barrier, but bring the exhaust out the top and make an air inlet at the bottom that goes to the air intake of the engine. You may need additional openings for ventilation to keep the engine from overheating. You may be able to bring the radiator outside the enclosure to solve that problem. Make sure you have a very good muffler. Look into finding a better one. You may be able to buy an enclosure for the generator, check with the manufacturer. PS, you seem to have this located indoors. That is a very bad idea.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products