Diesel generator Powered by Yuchai Engine,which yuchai is a large state-owned enterprise and a Nasdaq listed company in USA (NYSE:CYD). Its main business covers diesel engine, contruction machinery, vehicle parts. The engines produced by Yuchai include series YC6G, YC4G, YC4E to which American technology applied, series YC6A, YC6B, YC6J, YC4B, YC4D, YC4F, YC4W to which German technology applied, and YC6M series in which world top technology integrated, totally 12 series.
YUCHAI Series | Power(KW) | Power(KVA) | Jichai Engine Model | Cylinder NO. | Fuel consumption g/kw.h | DimensionL*W*H | Weight KG |
FKS-Y18 | 18 | 22.5 | YC2108D | 2 | ≤225 | 1700*700*1000 | 650 |
FKS-Y24 | 24 | 30 | YC2115D | 2 | ≤220 | 1700*700*1000 | 650 |
FKS-Y30 | 30 | 37.5 | YC2115ZD | 4 | ≤205 | 1700*750*1000 | 900 |
FKS-Y40 | 40 | 50 | YC4D60-D21 | 4 | ≤205 | 1800*750*1200 | 920 |
FKS-Y50 | 50 | 62.5 | YC4D85Z-D20 | 4 | ≤200 | 1800*750*1200 | 950 |
THY-64 | 64 | 80 | YC6B100-D20 | 6 | ≤205 | 2250*800*1300 | 1200 |
FKS-Y75 | 75 | 93.75 | YC6B135Z-D20 | 6 | ≤202 | 2250*800*1300 | 1250 |
FKS-Y90 | 90 | 112.5 | YC6B135Z-D20 | 6 | ≤202 | 2250*800*1300 | 1300 |
FKS-Y100 | 100 | 125 | YC6B155L-D21 | 6 | ≤200 | 2300*800*1300 | 1500 |
FKS-Y120 | 120 | 150 | YC6B180L-D20 | 6 | ≤192 | 2300*830*1300 | 1600 |
FKS-Y140 | 140 | 175 | YC6A210L-D20 | 6 | ≤192 | 2300*830*1300 | 1700 |
FKS-Y150 | 150 | 187.5 | YC6A230L-D20 | 6 | ≤192 | 2400*970*1500 | 2100 |
FKS-Y160 | 160 | 200 | YC6G245L-D20 | 6 | ≤195 | 2500*970*1500 | 2300 |
FKS-Y180 | 180 | 225 | YC6L285L-D30 | 6 | ≤197 | 2600*970*1550 | 2500 |
FKS-Y200 | 200 | 250 | YC6M350L-D20 | 6 | ≤197 | 3100*1050*1750 | 2750 |
FKS-Y220 | 220 | 275 | YC6M350L-D20 | 6 | ≤197 | 3100*1100*1750 | 2800 |
FKS-Y280 | 280 | 350 | YC6MK410L-D20 | 6 | ≤195 | 3200*1150*1750 | 3000 |
FKS-Y300 | 300 | 375 | YC6MK470L-D20 | 6 | ≤195 | 3200*1200*1750 | 3100 |
FKS-Y320 | 320 | 400 | YC6K500L-D30 | 6 | ≤195 | 3250*1200*1750 | 3200 |
FKS-Y350 | 350 | 437.5 | YC6K550L-D30 | 6 | ≤195 | 3250*1250*1750 | 3250 |
FKS-Y350 | 350 | 437.5 | YC6T550L-D21 | 6 | ≤195 | 3300*1250*1850 | 3500 |
FKS-Y400 | 400 | 500 | YC6T600L-D22 | 6 | ≤195 | 3400*1500*1970 | 3900 |
FKS-Y440 | 440 | 550 | YC6T660L-D20 | 6 | ≤195 | 3500*1500*1970 | 4000 |
FKS-Y500 | 500 | 625 | YC6T755L-D20 | 6 | ≤195 | 4000*1500*2000 | 5000 |
FKS-Y650 | 650 | 812.5 | YC6C1020L-D20 | 6 | ≤195 | 4500*1800*2500 | 7500 |
- Q:A couple years ago the power in our area was out for two whole weeks because of ice and such, we stayed warm thanks to gas heating but now I'm in an all electric mobile home in the same area. All I want to power is the refrigerator, deep freeze, microwave, one laptop and at least one, maybe two little plug in heaters.I need to know what size/type generator to get and if I need a separate kit or anything in order to hook up to my mobile home. I don't want to buy the wrong type or size and find out it doesn't work in the middle of an ice storm again.Thank you for any and all help, it's very much appreciated.
- add up the watts of the things you want to be on during an outage and get a generator with a little bit bigger output. you don't want to overwork a generator that's too small. bigger is always better.
- Q:Diesel fuel savers are available today for diesel engines. These can be used for most diesel engines from school buses, big rigs, cranes, off-road equipment, marine use, and generators. If a mandate was passed to require these units to be installed tremendose sums of money could be saved by end users. For more info visit bestdieselsolutions
- Legislation is not necessary, if it works people will buy it.
- Q:Im building a new house, and I would like to go totally off the grid in South-Central Oklahoma.Id like to be able to run the tv, freezer, refrigerator, and minimal lights and water well.Im looking for information on a complete system.Any ideas/? Im looking for the pros and cons of this way of life from homeowners that have actually done this.
- photo voltaic is the most uncomplicated thanks to bypass. the most inexpensive is small hydro, yet you go with a always flowing bypass or artesian properly. We run our residing house lights, pcs, leisure center, and an ability-celeb refrigerator on 800 watts of photo voltaic panel with 10 deep-discharge marine batteries for storage. undesirable climate ability I quite might want to apply a generator about 10 days a 365 days to correct up the batteries, used 15 gallons of gas very last 365 days. I plan on including yet another four hundred watts of panel and six extra batteries when I get a freezer later this 365 days. The generator is likewise sensible to run a welder and a table observed that take extra ability than my 2500watt inverter can placed out. universal, I quite have extra solid ability than my grid-depending acquaintances 2 miles down the line. in the adventure that your properly is windmill-pumped, keep on with it. we would want to haul water immediately, use a propane tankless heater gadget for showers. at the same time as the properly is for sale in we will be doing photo voltaic water heating. Many states have photo voltaic ability rebate courses, the feds actually have ability rebate and loose insulation courses. construction insulation is truly major in conserving heating criteria down. the nearest application organisation for your area would have information in case you are able to't turn it up in a Google seek for.
- Q:How long can I run a Diesel Power Generator before I have to stop it to give it a rest?Also, how many years can I expect a Cummins Diesel Generator to run if maintained properly?One more thing. In the spec sheet of the generator I'm looking at, it states 161 gsm/hp-hr. Is that 161 Grams per Horse Power per hour?So what does that meanHow many liters per hour does that translate too.Thanks for your answers.Greetings from Iran
- The engine can run indefinitely without needing to stop for a rest provided it is properly maintained and cooled. You should change the oil and filters after every 200 hours operating time. Properly maintained you should expect at least 25-30 years operating time from the engine. Neglected and it could need replacing in less than 10. Not sure what 161 gsm/hp-hr means. Unlikely to be grams, but gallons per horsepower hour would be extremely high. Need to look further into it
- Q:I want to run the generator just enough to feedback enough kilowatts to make my annual bill zero usage.
- Definitely not a good idea to do. Also illegal in most areas. Code dictates that generators be connected to a home electrical system with an isolation switch to prevent feeding electricity to the grid. That way if power is out, the lines will be dead . If power were out and generator not isolated the lineman could be electrocuted. Next is cost. I have a standby generator that runs on natural gas. HAd an extended power outage last fall. Cost about $2.00 an hour to run it.
- Q:There are several ways to start the diesel generator set?
- Diesel generator set manual start: first test alarm system is normal, the control switch is cut in the manual (MAN) position, the diesel generator set can start on their own
- Q:I live in a remote location and my power bill is just ridiculously expensive -- I did the math and it seems like it'll be way cheaper for me to use my solar panel (which currently supplies DC power to a few parts of the house) and a diesel/oil/propane generator (which I have yet to purchase), and just cut off all mains power.Question is, which of these configurations is better?1)-Solar panel-DC generator-Large battery bank-High-wattage inverterResult: AC power throughout the house, using both solar panel and generator to charge the batteries as needed2)-Solar panel-AC generator-Smaller battery bank (for solar panel only)-No inverterResult: AC power when generator running, DC power from solar panel and batteries (I use DC right now for lights and a few basic appliances so I can live without AC power)Or should I do a combination of both, like using an inverter for the solar panel to always provide AC power?Thanks.
- u ought to apply it with out batteries yet u'll choose batteries if u prefer to save electricity for whilst there's no sunlight or in case of a potential failure. grid linked PV platforms would possibly no longer particularly require batteries, so as that way it is going to become greater low-fee. so yeah i assume u ought to do away with batteries. if u do choose a battery(for potential cuts or nighttime time) i assume u ought to get one in each of those united statesbatteries (120V in line with threat) ,the greater moderen batteries dont certainly choose that plenty maintenance. with admire to a wind generator, i'm no longer particularly specific, so i'm unlikely to purpose and answer that one.
- Q:can't those nuclear material in japan be kept inside a container that is not affected by it like lead?or shifted to an isolated location.
- Humans have not quite figured out how to safely use nuclear energy. Despite the best technical minds in the world, Japan, Russia, and the USA have failed to prevent disasters. Having worked in the nuclear energy field for an energy company and as a vendor, I can tell you that the rules are bent regularly despite what the PR folks tell the world and all those painful paper trails. The world as presented by spokespeople, executives, and media does not exist. The idea that a bigger technological hammer will solve problems created by an already oversized and uncontrollable technology just is insane. A big lead cap will just cause an explosion that is even bigger and more widespread. The only solution is long term. We must stop this insane technology that benefits the very wealthy elite who profit by putting these projects together. GE and Bechtel make out like bandits. It's the tax payer and the rest of us who end up footing the bill. We also have an even more deadly pandemic underway thanks to our friends at Monsanto. A small percentage of folks are now suffering from gluten allergies that are the direct result of genetic modifications to wheat. Many common foods we eat, like wheat, corn, and soy is constantly being changed and the problems (allergies and built in pest resistance) is are not immediately apparent. Some instances of poisoning from GM products are documented, but many may not be linked to the real cause for many years, if at all. More technology is not the answer.
- Q:I have to distinct between these generator. Do any website provide detail of all type of generator for purpose of study? My main intention is how to differentiate mobile generator from others.
- Terminology may vary between manufacturers or dealers, but here is how I interpret the differences. RV generator is mounted internally to the RV. Remote start, feeds power to selected RV circuits only. It is supplied fuel from the vehicle tank. Typically up to about 8kW.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Factory price china yuchai diesel generator sets 75kw
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 300 unit/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches